Klima Pressure Switches (High & Low) in Mansheya, Alexandria
Mansheya is a commercial district in Alexandria, Egypt. Typical customers are shop-fitters, facilities teams and service contractors, and what they want is reliable parts for offices, retail units and food outlets.
The main users of pressure switches in Mansheya, Alexandria are offices, shops and malls as well as hotels and restaurants. The Klima range includes 4 models, each with a specification table; send an enquiry from Mansheya, Alexandria for a quotation.
- Area type
- Commercial district
- City
- Alexandria
- Country
- Egypt
- Climate
- Hot and arid
- Supply
- 230 V, 50 Hz
Klima Pressure Switches (High & Low) models
- Klima High Pressure Switch, Manual Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima High Pressure Switch, Auto Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima Low Pressure Switch, Auto Reset Type: Low pressure, Pressure range: -0.7 to 7 bar, Cut-out setting: Adjustable bar
- Klima Dual Pressure Switch, HP/LP Type: Dual HP/LP, Pressure range: HP 8 to 32, LP -0.7 to 7 bar, Cut-out setting: Adjustable bar
All Klima products for Mansheya, Alexandria ยท Klima Pressure Switches (High & Low) overview
Conditions in Mansheya, Alexandria that affect pressure switches
In Mansheya, Alexandria, air conditioning and refrigeration run for most of the year. In very hot weather discharge pressure climbs towards the safety limits; check that pressure switches are rated for the refrigerant in use, and keep condensers clean and fans healthy.
Dust blocks sensor openings and slows response; clean the vents of pressure switches at each service.
Mansheya, Alexandria at a glance
Mansheya is one of 8 areas listed for Alexandria; others include El Max, Dekheila Port, Borg El Arab and Agami. Alexandria has about 5.3 million people, roughly 180 km from Cairo, the capital.
Controls in Mansheya shops and offices are often handled by non-specialists. Pick models with clear labelling and simple settings, and note the settings you leave.
Other commercial districts in Alexandria
The directory lists 8 areas in Alexandria; 2 of them, including Mansheya, are commercial districts. More commercial districts in Alexandria, each with its own page, include Sidi Gaber. The rest of the areas listed for Alexandria are Borg El Arab, Montaza, Agami, Dekheila Port and El Max.
Typical uses of pressure switches in Mansheya, Alexandria
Pressure switches are most often specified in Mansheya, Alexandria for:
- Split, VRF and packaged air conditioners
- Condensing units and cold rooms
- Heat pump outdoor units
Klima pressure switches models
| Model | Type | Pressure range (bar) | Cut-out setting (bar) |
|---|---|---|---|
| Klima High Pressure Switch, Manual Reset | High pressure | 8 to 32 | Adjustable |
| Klima High Pressure Switch, Auto Reset | High pressure | 8 to 32 | Adjustable |
| Klima Low Pressure Switch, Auto Reset | Low pressure | -0.7 to 7 | Adjustable |
| Klima Dual Pressure Switch, HP/LP | Dual HP/LP | HP 8 to 32, LP -0.7 to 7 | Adjustable |
See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.
Selecting pressure switches in Mansheya, Alexandria
- Choose the refrigerant and its pressure range first, because cut-out values for R410A differ greatly from those for R22 or R134a.
- Ask for the datasheet and the documents your project needs; in Egypt that usually means EOS (Egyptian Organization for Standardization) conformity.
Care and maintenance in Mansheya, Alexandria
- Replace a switch that fails to trip at the specified pressure, and do not adjust a safety switch beyond its marked range.
Mansheya, Alexandria lies in the northern hemisphere, where cooling demand usually peaks from May to September. Schedule inspections of pressure switches for March or April, ahead of that peak. Checking setpoints and safety cut-outs in a quiet week is simpler than doing it during a heatwave.
Faults to watch for
- A switch that cycles at the wrong pressure
Supply and delivery to Mansheya, Alexandria
Deliveries for Mansheya are arranged to Alexandria; give a street address or a collection point in your enquiry.
National rules, standards and voltage for Egypt are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Questions about pressure switches in Mansheya, Alexandria
What is a dual pressure switch?
One body with both high- and low-pressure sensing and a combined contact, so a single connection protects both sides of the circuit.
What voltage should pressure switches be rated for in Mansheya, Alexandria?
Egypt supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so pressure switches rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.
How are pressure switches delivered to Mansheya, Alexandria?
Send the delivery address in Mansheya, or a collection point in Alexandria, together with the model and quantity you need.
What do buyers in Mansheya usually need?
Mansheya is a commercial district, so the buyers are mostly shop-fitters, facilities teams and service contractors. They want reliable parts for offices, retail units and food outlets.
More Klima products for Mansheya, Alexandria
- Klima Contactors in Mansheya, Alexandria
- Klima Filter Driers in Mansheya, Alexandria
- Klima Thermometers for HVAC in Mansheya, Alexandria
- Klima Map Gas (Brazing & Welding) in Mansheya, Alexandria
- Klima Transformer for HVAC in Mansheya, Alexandria
- Klima Cables (3 & 4 Core) in Mansheya, Alexandria
Pressure switches in other areas of Alexandria
- Klima Pressure Switches (High & Low) in Agami, Alexandria
- Klima Pressure Switches (High & Low) in Borg El Arab, Alexandria
- Klima Pressure Switches (High & Low) in Dekheila Port, Alexandria
- Klima Pressure Switches (High & Low) in El Max, Alexandria
- Klima Pressure Switches (High & Low) in Montaza, Alexandria
- Klima Pressure Switches (High & Low) in Sidi Gaber, Alexandria