Haram, Giza: Klima Pressure Switches (High & Low)
Haram is a residential district in Giza, Egypt. Buyers here are mostly home installers, small AC service teams and landlords, who look for standard replacement parts for split units, fridges and freezers.
The main users of pressure switches in Haram, Giza are homes and apartments. Klima Industries lists 4 models in this range with full specifications below, and enquiries from Haram, Giza are welcome.
- Area type
- Residential district
- City
- Giza
- Country
- Egypt
- Climate
- Hot and arid
- Supply
- 230 V, 50 Hz
Klima Pressure Switches (High & Low) models
- Klima High Pressure Switch, Manual Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima High Pressure Switch, Auto Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima Low Pressure Switch, Auto Reset Type: Low pressure, Pressure range: -0.7 to 7 bar, Cut-out setting: Adjustable bar
- Klima Dual Pressure Switch, HP/LP Type: Dual HP/LP, Pressure range: HP 8 to 32, LP -0.7 to 7 bar, Cut-out setting: Adjustable bar
All Klima products for Haram, Giza ยท Klima Pressure Switches (High & Low) overview
Conditions in Haram, Giza that affect pressure switches
In Haram, Giza, air conditioning and refrigeration run for most of the year. In very hot weather discharge pressure climbs towards the safety limits; check that pressure switches are rated for the refrigerant in use, and keep condensers clean and fans healthy.
Dust blocks sensor openings and slows response; clean the vents of pressure switches at each service.
About supply to Haram, Giza
Haram is one of 6 areas listed for Giza; others include Agouza, Faisal, Dokki and Mohandessin. Giza has about 4.4 million people, roughly 7 km from Cairo, the capital.
Home thermostats and controllers in Haram are best chosen by compatibility with the existing unit: voltage, wiring and the type of system.
Where Haram fits in Giza
The directory lists 6 areas in Giza; 2 of them, including Haram, are residential districts. More residential districts in Giza, each with its own page, include Faisal. The rest of the areas listed for Giza are Mohandessin, Dokki, Agouza and 6th of October City.
Where pressure switches are used in Haram, Giza
Pressure switches are most often specified in Haram, Giza for:
- Split, VRF and packaged air conditioners
- Heat pump outdoor units
- Condensing units and cold rooms
Klima pressure switches models
| Model | Type | Pressure range (bar) | Cut-out setting (bar) |
|---|---|---|---|
| Klima High Pressure Switch, Manual Reset | High pressure | 8 to 32 | Adjustable |
| Klima High Pressure Switch, Auto Reset | High pressure | 8 to 32 | Adjustable |
| Klima Low Pressure Switch, Auto Reset | Low pressure | -0.7 to 7 | Adjustable |
| Klima Dual Pressure Switch, HP/LP | Dual HP/LP | HP 8 to 32, LP -0.7 to 7 | Adjustable |
See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.
Selecting pressure switches in Haram, Giza
- Use an HP switch with manual reset for safety duty and an LP switch with automatic reset for pump-down or control duty.
- Ask for the datasheet and the documents your project needs; in Egypt that usually means EOS (Egyptian Organization for Standardization) conformity.
Keeping pressure switches reliable in Haram, Giza
- Check that connections are leak-free and that capillary tubes are not kinked.
In the northern hemisphere the busiest cooling months fall from May to September; March or April is a sensible time to check pressure switches in Haram, Giza. Controls drift over time; verify setpoints and switch points before the demanding months.
Faults to watch for
- Frequent unexplained compressor lockouts
Getting pressure switches to Haram, Giza
Deliveries for Haram are arranged to Giza; give a street address or a collection point in your enquiry.
National rules, standards and voltage for Egypt are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Questions about pressure switches in Haram, Giza
What does a high pressure switch do?
It opens the control circuit if discharge pressure rises above a set limit, which stops the compressor before the pressure can damage it or the pipework.
What voltage should pressure switches be rated for in Haram, Giza?
The mains supply in Egypt is 230 V, 50 Hz. Match pressure switches to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
How are pressure switches delivered to Haram, Giza?
Send the delivery address in Haram, or a collection point in Giza, together with the model and quantity you need.
What do buyers in Haram usually need?
Haram is a residential district, so the buyers are mostly home installers, small AC service teams and landlords. They want standard replacement parts for split units, fridges and freezers.
More Klima products for Haram, Giza
- Klima Contactors in Haram, Giza
- Klima Filter Driers in Haram, Giza
- Klima Thermometers for HVAC in Haram, Giza
- Klima Thermostats in Haram, Giza
- Klima Drier Core 48-KL in Haram, Giza
- Klima Flux Powder (100 g & 250 g) in Haram, Giza