Pressure switches supply in Acharnes, Athens
Acharnes is an industrial area in Athens, Greece. Buyers here are mostly maintenance contractors, plant operators and workshops, who look for exact-match replacements, fast turnaround and trade quantities.
The main users of pressure switches in Acharnes, Athens are factories and workshops as well as cold stores and food distribution. Klima Industries lists 4 models in this range with full specifications below, and enquiries from Acharnes, Athens are welcome.
- Area type
- Industrial area
- City
- Athens
- Country
- Greece
- Climate
- Mediterranean
- Supply
- 230 V, 50 Hz
Klima Pressure Switches (High & Low) models
- Klima High Pressure Switch, Manual Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima High Pressure Switch, Auto Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima Low Pressure Switch, Auto Reset Type: Low pressure, Pressure range: -0.7 to 7 bar, Cut-out setting: Adjustable bar
- Klima Dual Pressure Switch, HP/LP Type: Dual HP/LP, Pressure range: HP 8 to 32, LP -0.7 to 7 bar, Cut-out setting: Adjustable bar
All Klima products for Acharnes, Athens ยท Klima Pressure Switches (High & Low) overview
Conditions in Acharnes, Athens that affect pressure switches
In Acharnes, Athens, cooling demand peaks from late spring to early autumn. High ambient temperatures push condensing pressure up, so pressure switches must suit the higher working pressure and the system needs a clean condenser to stay inside its limits.
Large seasonal swings mean set points move; review the settings of pressure switches at the start of each season and recheck calibration.
About supply to Acharnes, Athens
Acharnes is one of 10 areas listed for Athens; others include Syntagma, Glyfada, Piraeus and Kifisia. Athens has about 664,000 people, the national capital.
Plant rooms in Acharnes rely on controls that stay stable under vibration and dust; check the enclosure rating and fixing style, not only the setpoint range.
Where Acharnes fits in Athens
Of the 10 areas named for Athens, 4 are industrial areas, and Acharnes is one of them. More industrial areas in Athens, each with its own page, include Votanikos, Aspropyrgos and Elefsina. Elsewhere in Athens the directory also names Glyfada, Syntagma, Piraeus, Marousi and Kifisia.
Where pressure switches are used in Acharnes, Athens
In Acharnes, Athens, these are the jobs that most often call for pressure switches:
- Supermarket racks and display cases
- Refrigerated transport and containers
- Ice machines and process cooling
Klima pressure switches models
| Model | Type | Pressure range (bar) | Cut-out setting (bar) |
|---|---|---|---|
| Klima High Pressure Switch, Manual Reset | High pressure | 8 to 32 | Adjustable |
| Klima High Pressure Switch, Auto Reset | High pressure | 8 to 32 | Adjustable |
| Klima Low Pressure Switch, Auto Reset | Low pressure | -0.7 to 7 | Adjustable |
| Klima Dual Pressure Switch, HP/LP | Dual HP/LP | HP 8 to 32, LP -0.7 to 7 | Adjustable |
See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.
Choosing pressure switches for Acharnes, Athens
- Check the electrical rating against the contactor coil or control circuit it will switch.
- Confirm the supply first: Greece uses 230 V at 50 Hz, so check the voltage and frequency rating of pressure switches against the equipment nameplate.
Keeping pressure switches reliable in Acharnes, Athens
- Replace a switch that fails to trip at the specified pressure, and do not adjust a safety switch beyond its marked range.
Because Acharnes, Athens is in the northern hemisphere, the heaviest cooling load normally falls from June to September. Service pressure switches in April or May, while the load is still light. Checking setpoints and safety cut-outs in a quiet week is simpler than doing it during a heatwave.
Signs of trouble
- Frequent unexplained compressor lockouts
Getting pressure switches to Acharnes, Athens
Send the delivery address in Acharnes, or a collection point in Athens, together with the model and quantity you need.
National rules, standards and voltage for Greece are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Pressure switches in Acharnes, Athens: common questions
What is a dual pressure switch?
One body with both high- and low-pressure sensing and a combined contact, so a single connection protects both sides of the circuit.
What voltage should pressure switches be rated for in Acharnes, Athens?
With a 230 V, 50 Hz supply, Greece follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every pressure switch against the equipment it serves.
How are pressure switches delivered to Acharnes, Athens?
Deliveries for Acharnes are arranged to Athens; give a street address or a collection point in your enquiry.
What do buyers in Acharnes usually need?
Acharnes is an industrial area, so the buyers are mostly maintenance contractors, plant operators and workshops. They want exact-match replacements, fast turnaround and trade quantities.
More Klima products for Acharnes, Athens
- Klima Contactors in Acharnes, Athens
- Klima Filter Driers in Acharnes, Athens
- Klima Thermometers for HVAC in Acharnes, Athens
- Klima Terminal Crimps in Acharnes, Athens
- Klima Delay on Make Timer in Acharnes, Athens
- Klima Copper Coils & Tubes in Acharnes, Athens
Pressure switches in other areas of Athens
- Klima Pressure Switches (High & Low) in Aspropyrgos, Athens
- Klima Pressure Switches (High & Low) in Elefsina, Athens
- Klima Pressure Switches (High & Low) in Glyfada, Athens
- Klima Pressure Switches (High & Low) in Kallithea, Athens
- Klima Pressure Switches (High & Low) in Kifisia, Athens
- Klima Pressure Switches (High & Low) in Marousi, Athens