Klima Industries

Klima pressure switches for Saint George's

With about 7,500 people, Saint George's is a smaller city in Grenada. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.

Pressure switches are bought here mainly for offices, shops and malls, factories and workshops as well as homes and apartments. Klima Industries lists 4 models in this range with full specifications below, and enquiries from Saint George's are welcome.

Country
Grenada
Population
7,500
Climate
Hot and humid tropical
Coordinates
12.1° N, 61.8° W
Time zone
UTC-4 all year
Supply
230 V, 50 Hz

Klima Pressure Switches (High & Low) models

All Klima products for Saint George's · Klima Pressure Switches (High & Low) overview

What Saint George's demands of pressure switches

In Saint George's, cooling and refrigeration work in every month of the year. Humid air makes moisture ingress the biggest installation risk, so keep pressure switches sealed until use, braze under nitrogen and evacuate to a deep vacuum before charging.

In very hot weather a badly placed control keeps the compressor running; mount pressure switches out of direct sun and away from heat sources.

About supply to Saint George's

Saint George's is the only city listed for Grenada, with about 7,500 people. Enquiries from anywhere in the country can use this page.

In a smaller city like Saint George's, a replacement control can mean a long wait. Keep a spare for critical equipment and check that the range matches the original.

Time zone, sun and daylight in Saint George's

The clock in Saint George's follows UTC-4 all year.

At 12.1° N, Saint George's has about 12 h 50 min of daylight at the June solstice and about 11 h 25 min at the December solstice. The noon sun stands 79° above the horizon in June and 55° in December, and the sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat.

Where pressure switches are used in Saint George's

In Saint George's, these are the jobs that most often call for pressure switches:

  • Split, VRF and packaged air conditioners
  • Chillers and air-cooled condensers
  • Fan speed control by head pressure

Klima pressure switches models

ModelTypePressure range (bar)Cut-out setting (bar)
Klima High Pressure Switch, Manual ResetHigh pressure8 to 32Adjustable
Klima High Pressure Switch, Auto ResetHigh pressure8 to 32Adjustable
Klima Low Pressure Switch, Auto ResetLow pressure-0.7 to 7Adjustable
Klima Dual Pressure Switch, HP/LPDual HP/LPHP 8 to 32, LP -0.7 to 7Adjustable

See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.

Choosing pressure switches for Saint George's

  • Match the connection (flare size or capillary) to the service port you will use.
  • Confirm the supply first: Grenada uses 230 V at 50 Hz, so check the voltage and frequency rating of pressure switches against the equipment nameplate.

Keeping pressure switches reliable in Saint George's

  • Test cut-out and cut-in values with a gauge manifold and nitrogen or a controlled pressure source at commissioning.

A tropical climate keeps cooling demand steady through the year in Saint George's, so there is no quiet season. Schedule checks of pressure switches around the main rainy-season changes and keep spares on hand. Calibrate and test controls under easy conditions so settings are proven before the load rises.

Faults to watch for

  • A switch that cycles at the wrong pressure

Getting pressure switches to Saint George's

Shipments for Saint George's normally clear customs at one of the main entry points of Grenada and finish the journey by road; send your delivery address with the enquiry.

National rules, standards and voltage for Grenada are summarised on the country page.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Pressure switches in Saint George's: common questions

How do I set the cut-out pressure?

Take the value from the equipment manual for the refrigerant in use and verify it with a gauge set. Never set a switch above the pressure rating of the components it protects.

What voltage should pressure switches be rated for in Saint George's?

The mains supply in Grenada is 230 V, 50 Hz. Match pressure switches to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.

How are pressure switches delivered to Saint George's?

To order pressure switches for Saint George's, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

Which parts of Saint George's can I order for?

Enquiries are welcome from every part of Saint George's. Send the delivery address with your enquiry.

What local time and daylight should I plan for in Saint George's?

Saint George's keeps UTC-4 all year. At 12.1° N there are about 12 h 50 min of daylight in June and about 11 h 25 min in December.

More Klima products for Saint George's