Khanaqin is a smaller city in Iraq. The climate is hot and arid. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.

The main users of pressure switches in Khanaqin are offices, shops and malls as well as homes and apartments. The Klima range includes 4 models, each with a specification table; send an enquiry from Khanaqin for a quotation.

Country
Iraq
Population
175,000
Climate
Hot and arid
Coordinates
34.3° N, 45.4° E
Time zone
UTC+3 all year
From Baghdad
145 km north-east
Supply
230 V, 50 Hz

Klima Pressure Switches (High & Low) models

All Klima products for Khanaqin · Klima Pressure Switches (High & Low) overview

Pressure switches and the climate in Khanaqin

In Khanaqin, air conditioning and refrigeration run for most of the year. High ambient temperatures push condensing pressure up, so pressure switches must suit the higher working pressure and the system needs a clean condenser to stay inside its limits.

Dust blocks sensor openings and slows response; clean the vents of pressure switches at each service.

Cities around Khanaqin that need pressure switches

By population Khanaqin is 24th of the 33 cities listed for Iraq, with roughly 0.7% of their combined population, about 2.4% of the size of Baghdad, the largest. Khanaqin lies about 145 km north-east of Baghdad, the capital. For scale, Oshawa in Canada has a similar population (175,000).

Nearest to Khanaqin: Kelar (32 km north), Al Miqdadiyah (59 km south-west) and Baqubah (98 km south-west). Three other listed cities lie within 100 km, and 20 within 300 km. The farthest listed city in Iraq is Al Basrah al Qadimah, about 484 km south-east of Khanaqin.

CityDistancePeopleWhat wears pressure switches first
Kelar32 km north250,000sensor drift and setpoints creeping
Al Miqdadiyah59 km south-west156,000dust in enclosures and sticky switches
Baqubah98 km south-west153,000dust in enclosures and sticky switches
Sulaymaniyah135 km north878,000sensor drift and setpoints creeping
Samarra'139 km west159,000sensor drift and setpoints creeping
Baghdad145 km south-west7.2 millionsensor drift and setpoints creeping

In a smaller city like Khanaqin, a replacement control can mean a long wait. Keep a spare for critical equipment and check that the range matches the original.

Time zone, sun and daylight in Khanaqin

Local time in Khanaqin is UTC+3 all year.

Sunlight at 34.3° N (Khanaqin): about 14 h 27 min of daylight in June, about 9 h 51 min in December, and a noon sun that reaches 79° in June and 32° in December. At its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. Khanaqin has a hot and arid climate, the same as the country as a whole, and 32 other listed cities share it.

Typical uses of pressure switches in Khanaqin

In Khanaqin, these are the jobs that most often call for pressure switches:

  • Split, VRF and packaged air conditioners
  • Heat pump outdoor units
  • Condensing units and cold rooms

Klima pressure switches models

ModelTypePressure range (bar)Cut-out setting (bar)
Klima High Pressure Switch, Manual ResetHigh pressure8 to 32Adjustable
Klima High Pressure Switch, Auto ResetHigh pressure8 to 32Adjustable
Klima Low Pressure Switch, Auto ResetLow pressure-0.7 to 7Adjustable
Klima Dual Pressure Switch, HP/LPDual HP/LPHP 8 to 32, LP -0.7 to 7Adjustable

See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.

Selecting pressure switches in Khanaqin

  • Match the connection (flare size or capillary) to the service port you will use.
  • Ask for the datasheet and the documents your project needs; in Iraq that usually means COSQC conformity.

Care and maintenance in Khanaqin

  • Replace a switch that fails to trip at the specified pressure, and do not adjust a safety switch beyond its marked range.

In the northern hemisphere the busiest cooling months fall from May to September; March or April is a sensible time to check pressure switches in Khanaqin. Controls drift over time; verify setpoints and switch points before the demanding months.

Faults to watch for

  • A unit that does not restart after a trip

Supply and delivery to Khanaqin

Shipments for Khanaqin normally clear customs at one of the main entry points of Iraq and finish the journey by road; send your delivery address with the enquiry.

National rules, standards and voltage for Iraq are summarised on the country page.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Questions about pressure switches in Khanaqin

What does a high pressure switch do?

It opens the control circuit if discharge pressure rises above a set limit, which stops the compressor before the pressure can damage it or the pipework.

What voltage should pressure switches be rated for in Khanaqin?

The mains supply in Iraq is 230 V, 50 Hz. Match pressure switches to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.

How are pressure switches delivered to Khanaqin?

To order pressure switches for Khanaqin, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

Which parts of Khanaqin can I order for?

Enquiries are welcome from every part of Khanaqin. Send the delivery address with your enquiry.

What local time and daylight should I plan for in Khanaqin?

Khanaqin keeps UTC+3 all year. At 34.3° N there are about 14 h 27 min of daylight in June and about 9 h 51 min in December.

Which cities near Khanaqin can the same order serve?

The listed cities closest to Khanaqin are Kelar (32 km north), Al Miqdadiyah (59 km south-west) and Baqubah (98 km south-west). Combine them into one order and give each delivery address.

More Klima products for Khanaqin

Pressure switches in cities near Khanaqin