Klima Industries

Pressure switches for Latvia

Latvia is a smaller national market in Europe, and its capital is Riga. Most of the country has a continental climate, and conditions vary by region. Summers are warm to hot and winters are cold, with a wide swing between the seasons.

The main users of pressure switches in Latvia are offices, shops and malls, factories and workshops as well as homes and apartments. Klima Industries lists 4 models in this range with full specifications below, and enquiries from Latvia are welcome.

Capital
Riga
Population
1.9 million
Area
64,589 km²
Time zone
UTC+2, moving to UTC+3 while daylight saving applies
Climate
Continental
Supply
230 V, 50 Hz
Main ports
Riga
Standards
CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations

Klima Pressure Switches (High & Low) models

All Klima products for Latvia · Klima Pressure Switches (High & Low) overview

What Latvia demands of pressure switches

In Latvia, cooling peaks in a short, hot summer, and sub-zero spells are normal in winter. Seasonal expansion and contraction stress pipework and joints, so support lines properly and inspect joints near pressure switches for oil traces after the first hot and the first cold spells.

Cold weather calls for the right defrost and low-ambient settings, and for pressure switches whose range reaches the temperatures you need.

Latvia supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so pressure switches rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.

Where pressure switches are needed in Latvia

From Liepaja to Rezekne, the longest straight-line gap between listed cities is about 388 km; so most deliveries inside the country stay within a day of road. Riga is both the capital and the largest listed city, with about 743,000 people, so the capital is also the biggest single market. These are the biggest listed cities in Latvia; the last column names what to watch for in pressure switches there.

CityPeopleClimateWhat wears pressure switches first
Riga743,000continentalslow response and frozen sensing bulbs
Daugavpils78,000continentalslow response and frozen sensing bulbs
Liepaja67,000continentalslow response and frozen sensing bulbs
Ventspils33,000continentalcalibration drift between seasons
Valmiera23,000continentalslow response and frozen sensing bulbs
Jekabpils21,000continentalcalibration drift between seasons

All 11 listed cities share a continental climate, so one stocking plan covers the whole country.

Size and settlement in Latvia

The directory puts Latvia at about 64,589 km², the 117th smallest of its 241 countries, almost exactly the size of Lithuania (65,200 km²). With 1.9 million residents the average density is 30 per km², so Latvia counts as moderately settled, sparser than 76% of the other countries in this directory. People and businesses cluster around the main cities, so say which city or region the delivery is for. Its population is similar to that of Guinea-Bissau (1.9 million).

Time zone, sun and daylight in Latvia

Local time in Riga is UTC+2, moving to UTC+3 while daylight saving applies.

Sunlight at 56.9° N (Riga): about 17 h 52 min of daylight in June, about 6 h 43 min in December, and a noon sun that reaches 56° in June and 10° in December. The summer sun is high, so outdoor units in unshaded spots take strong direct heat.

Jobs in Latvia that call for pressure switches

Pressure switches are most often specified in Latvia for:

  • Split, VRF and packaged air conditioners
  • Chillers and air-cooled condensers
  • Fan speed control by head pressure
  • Heat pump outdoor units
  • Water-cooled condensers and cooling-tower circuits

Klima pressure switches models

ModelTypePressure range (bar)Cut-out setting (bar)
Klima High Pressure Switch, Manual ResetHigh pressure8 to 32Adjustable
Klima High Pressure Switch, Auto ResetHigh pressure8 to 32Adjustable
Klima Low Pressure Switch, Auto ResetLow pressure-0.7 to 7Adjustable
Klima Dual Pressure Switch, HP/LPDual HP/LPHP 8 to 32, LP -0.7 to 7Adjustable

See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.

Selecting pressure switches in Latvia

  • Check the electrical rating against the contactor coil or control circuit it will switch.
  • Choose the refrigerant and its pressure range first, because cut-out values for R410A differ greatly from those for R22 or R134a.
  • Confirm the supply first: Latvia uses 230 V at 50 Hz, so check the voltage and frequency rating of pressure switches against the equipment nameplate.
  • For continental conditions in Latvia, allow for wide seasonal temperature swings.

Keeping pressure switches reliable in Latvia

  • Replace a switch that fails to trip at the specified pressure, and do not adjust a safety switch beyond its marked range.

In the northern hemisphere the busiest cooling months fall from June to August; April or May is a sensible time to check pressure switches in Latvia. Controls drift over time; verify setpoints and switch points before the demanding months.

Faults to watch for

  • A switch that cycles at the wrong pressure

Which standards apply to pressure switches in Latvia

Klima pressure switches are specified against EN 12263 (safety switching devices for limiting pressure in refrigerating systems), IEC 60947-5-1. For import and installation in Latvia, buyers also meet CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations. Ask for the datasheet and conformity documents for the Klima model you plan to specify, so that submittals and import paperwork are complete.

Getting pressure switches to Latvia

Sea freight into Latvia normally clears through ports such as Riga, with onward delivery by road; urgent parts can travel by air.

The local currency is the Euro (EUR), so confirm the quotation currency and delivery terms before you order. The main languages are Latvian, Russian and Lithuanian; this site and its enquiry form are in English.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Pressure switches in Latvia: common questions

What does a low pressure switch do?

It stops the compressor when suction pressure falls too low, protecting it from running with too little refrigerant and preventing evaporator icing.

What voltage should pressure switches be rated for in Latvia?

The mains supply in Latvia is 230 V, 50 Hz. Match pressure switches to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.

Which standards apply to pressure switches in Latvia?

Klima pressure switches follow EN 12263 (safety switching devices for limiting pressure in refrigerating systems), IEC 60947-5-1. In Latvia the local framework is CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations; request the datasheet and conformity documents with your enquiry.

How are pressure switches delivered to Latvia?

Cargo for Latvia usually arrives through Riga; tell us your preferred port or delivery address with your enquiry.

Which cities in Latvia can I order pressure switches for?

Every listed city is covered. The largest are Riga (743,000), Daugavpils (78,000), Liepaja (67,000), Jelgava (55,000) and Ventspils (33,000). The country page lists the rest.

What local time and daylight should I plan for in Latvia?

Riga keeps UTC+2, moving to UTC+3 while daylight saving applies. At 56.9° N there are about 17 h 52 min of daylight in June and about 6 h 43 min in December.

Do the neighbours of Latvia use the same mains supply?

Yes. All 4 listed neighbours (Lithuania, Estonia, Belarus and Russia) run on a nominal 230 V at 50 Hz, the same as Latvia, so the electrical rating of a part does not usually change at the border.

More Klima products for Latvia