Klima pressure switches for Ambilobe
Ambilobe is a smaller city in Madagascar. The climate is hot and humid tropical. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
The main users of pressure switches in Ambilobe are offices, shops and malls as well as factories and workshops. The range below has 4 models; send an enquiry with the model code and your delivery address in Ambilobe.
- Country
- Madagascar
- Population
- 66,000
- Climate
- Hot and humid tropical
- Coordinates
- 13.2° S, 49.1° E
- Time zone
- UTC+3 all year
- From Antananarivo
- 656 km north
- Supply
- 230 V, 50 Hz
Klima Pressure Switches (High & Low) models
- Klima High Pressure Switch, Manual Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima High Pressure Switch, Auto Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima Low Pressure Switch, Auto Reset Type: Low pressure, Pressure range: -0.7 to 7 bar, Cut-out setting: Adjustable bar
- Klima Dual Pressure Switch, HP/LP Type: Dual HP/LP, Pressure range: HP 8 to 32, LP -0.7 to 7 bar, Cut-out setting: Adjustable bar
All Klima products for Ambilobe · Klima Pressure Switches (High & Low) overview
Pressure switches and the climate in Ambilobe
In Ambilobe, cooling and refrigeration work in every month of the year. Every minute an open circuit spends in humid air adds moisture, which turns into acid in the oil; fit new pressure switches last and keep the system closed until you are ready to evacuate.
Sun-warmed walls make thermostats read high; place pressure switches on interior walls away from sunlight and supply air so that the set point reflects the room, not the wall.
Where pressure switches go from Ambilobe
Among the 28 listed cities in Madagascar, Ambilobe comes 13th by population, with about 1.7% of the listed urban population, roughly 4.9% of the size of the largest city, Antananarivo. Ambilobe lies about 656 km north of Antananarivo, the capital. It is about the same size as Beruniy in Uzbekistan, which has 66,000.
Nearest to Ambilobe: Ambanja (83 km south-west), Hell-Ville (88 km west) and Antsiranana (102 km north). Two other listed cities lie within 100 km, and six within 300 km. The farthest listed city in Madagascar is Ambovombe, about 1,368 km south of Ambilobe.
| City | Distance | People | What wears pressure switches first |
|---|---|---|---|
| Ambanja | 83 km south-west | 64,000 | condensation inside enclosures |
| Hell-Ville | 88 km west | 53,000 | sensor drift and setpoints creeping |
| Antsiranana | 102 km north | 137,000 | sensor drift and setpoints creeping |
| Sambava | 169 km south-east | 89,000 | condensation inside enclosures |
| Antalaha | 231 km south-east | 72,000 | sensor drift and setpoints creeping |
| Maroantsetra | 259 km south | 45,000 | condensation inside enclosures |
In a smaller city like Ambilobe, a replacement control can mean a long wait. Keep a spare for critical equipment and check that the range matches the original.
Time zone, sun and daylight in Ambilobe
The clock in Ambilobe follows UTC+3 all year.
At 13.2° S, Ambilobe has about 11 h 21 min of daylight at the June solstice and about 12 h 54 min at the December solstice. The noon sun stands 53° above the horizon in June and 80° in December, and the sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. Unlike the highland country as a whole, Ambilobe is hot and humid tropical; 23 other listed cities share it.
Where pressure switches are used in Ambilobe
Pressure switches are most often specified in Ambilobe for:
- Split, VRF and packaged air conditioners
- Heat pump outdoor units
- Chillers and air-cooled condensers
Klima pressure switches models
| Model | Type | Pressure range (bar) | Cut-out setting (bar) |
|---|---|---|---|
| Klima High Pressure Switch, Manual Reset | High pressure | 8 to 32 | Adjustable |
| Klima High Pressure Switch, Auto Reset | High pressure | 8 to 32 | Adjustable |
| Klima Low Pressure Switch, Auto Reset | Low pressure | -0.7 to 7 | Adjustable |
| Klima Dual Pressure Switch, HP/LP | Dual HP/LP | HP 8 to 32, LP -0.7 to 7 | Adjustable |
See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.
Selecting pressure switches in Ambilobe
- Take the setting from the compressor or unit manual and stay below the design pressure of the weakest component.
- Confirm the supply first: Madagascar uses 230 V at 50 Hz, so check the voltage and frequency rating of pressure switches against the equipment nameplate.
Care and maintenance in Ambilobe
- Check that connections are leak-free and that capillary tubes are not kinked.
With little seasonal change in temperature, air conditioning in Ambilobe works almost every day. Spread checks of pressure switches through the year instead of waiting for a peak. Calibrate and test controls under easy conditions so settings are proven before the load rises.
Faults to watch for
- Frequent unexplained compressor lockouts
Ordering pressure switches for Ambilobe
Shipments for Ambilobe normally clear customs at one of the main entry points of Madagascar and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Madagascar are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Questions about pressure switches in Ambilobe
Should I choose manual or automatic reset?
Choose manual reset for safety (HP) duty, because it forces a technician to investigate. Automatic reset suits low-pressure control such as pump-down.
What voltage should pressure switches be rated for in Ambilobe?
Madagascar supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so pressure switches rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.
How are pressure switches delivered to Ambilobe?
To order pressure switches for Ambilobe, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Ambilobe can I order for?
Enquiries are welcome from every part of Ambilobe. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Ambilobe?
Ambilobe keeps UTC+3 all year. At 13.2° S there are about 11 h 21 min of daylight in June and about 12 h 54 min in December.
Which cities near Ambilobe can the same order serve?
The listed cities closest to Ambilobe are Ambanja (83 km south-west), Hell-Ville (88 km west) and Antsiranana (102 km north). Combine them into one order and give each delivery address.
More Klima products for Ambilobe
- Klima Contactors in Ambilobe
- Klima Filter Driers in Ambilobe
- Klima Thermometers for HVAC in Ambilobe
- Klima Condensate Pump in Ambilobe
- Klima Flux Powder (100 g & 250 g) in Ambilobe
- Klima Thermostat Guards in Ambilobe
Pressure switches in cities near Ambilobe
- Klima Pressure Switches (High & Low) in Ambanja (about 83 km)
- Klima Pressure Switches (High & Low) in Hell-Ville (about 88 km)
- Klima Pressure Switches (High & Low) in Antsiranana (about 102 km)
- Klima Pressure Switches (High & Low) in Sambava (about 169 km)
- Klima Pressure Switches (High & Low) in Antalaha (about 231 km)