Pressure switches supply in Inaruwa
Inaruwa is a smaller city in Nepal. The climate is humid subtropical. Summers are hot and humid, with heavy seasonal rain, while winters are cooler and milder.
Pressure switches are bought here mainly for offices, shops and malls as well as homes and apartments. The Klima range includes 4 models, each with a specification table; send an enquiry from Inaruwa for a quotation.
- Country
- Nepal
- Population
- 70,000
- Climate
- Humid subtropical
- Coordinates
- 26.6° N, 87.1° E
- Time zone
- UTC+5:45 all year
- From Kathmandu
- 218 km south-east
- Supply
- 230 V, 50 Hz
Klima Pressure Switches (High & Low) models
- Klima High Pressure Switch, Manual Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima High Pressure Switch, Auto Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima Low Pressure Switch, Auto Reset Type: Low pressure, Pressure range: -0.7 to 7 bar, Cut-out setting: Adjustable bar
- Klima Dual Pressure Switch, HP/LP Type: Dual HP/LP, Pressure range: HP 8 to 32, LP -0.7 to 7 bar, Cut-out setting: Adjustable bar
All Klima products for Inaruwa · Klima Pressure Switches (High & Low) overview
What Inaruwa demands of pressure switches
In Inaruwa, cooling demand peaks through a long, humid summer. Humid air makes moisture ingress the biggest installation risk, so keep pressure switches sealed until use, braze under nitrogen and evacuate to a deep vacuum before charging.
In very hot weather a badly placed control keeps the compressor running; mount pressure switches out of direct sun and away from heat sources.
Pressure switches in Inaruwa and the cities near it
Inaruwa ranks 16th of the 29 listed cities in Nepal and holds about 1.4% of the people living in them, roughly 4.9% of the size of the largest city, Kathmandu. Inaruwa lies about 218 km south-east of Kathmandu, the capital. For scale, Faranah in Guinea has a similar population (70,000).
The closest are Itahari (14 km north-east), Biratnagar (21 km south-east) and Dharan (27 km north-east). Seven other listed cities lie within 100 km, and 16 within 300 km. At the other extreme, Bhimdatta is about 734 km north-west of Inaruwa, the furthest listed city in Nepal.
| City | Distance | People | What wears pressure switches first |
|---|---|---|---|
| Itahari | 14 km north-east | 48,000 | condensation inside enclosures |
| Biratnagar | 21 km south-east | 245,000 | condensation inside enclosures |
| Dharan | 27 km north-east | 173,000 | condensation inside enclosures |
| Rajbiraj | 40 km west | 70,000 | sensor drift and setpoints creeping |
| Triyuga | 49 km north-west | 71,000 | sensor drift and setpoints creeping |
| Lahan | 67 km west | 103,000 | condensation inside enclosures |
In a smaller city like Inaruwa, a replacement control can mean a long wait. Keep a spare for critical equipment and check that the range matches the original.
The sun and the clock in Inaruwa
The clock in Inaruwa follows UTC+5:45 all year.
Inaruwa lies at 26.6° N, 87.1° E. Daylight lasts about 13 h 49 min at the June solstice and about 10 h 28 min in December, with a noon sun 87° and 40° high; at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. Inaruwa has a humid subtropical climate, which differs from the highland climate that describes Nepal overall; 27 other listed cities share it.
Where pressure switches are used in Inaruwa
Typical work in Inaruwa that needs pressure switches:
- Split, VRF and packaged air conditioners
- Heat pump outdoor units
- Condensing units and cold rooms
Klima pressure switches models
| Model | Type | Pressure range (bar) | Cut-out setting (bar) |
|---|---|---|---|
| Klima High Pressure Switch, Manual Reset | High pressure | 8 to 32 | Adjustable |
| Klima High Pressure Switch, Auto Reset | High pressure | 8 to 32 | Adjustable |
| Klima Low Pressure Switch, Auto Reset | Low pressure | -0.7 to 7 | Adjustable |
| Klima Dual Pressure Switch, HP/LP | Dual HP/LP | HP 8 to 32, LP -0.7 to 7 | Adjustable |
See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.
How to pick pressure switches for work in Inaruwa
- Use an HP switch with manual reset for safety duty and an LP switch with automatic reset for pump-down or control duty.
- Ask for the datasheet and the documents your project needs; in Nepal that usually means NBSM (Nepal Bureau of Standards and Metrology) requirements.
Keeping pressure switches reliable in Inaruwa
- Test cut-out and cut-in values with a gauge manifold and nitrogen or a controlled pressure source at commissioning.
Inaruwa lies in the northern hemisphere, where cooling demand usually peaks from June to September. Schedule inspections of pressure switches for April or May, ahead of that peak. Controls drift over time; verify setpoints and switch points before the demanding months.
Signs of trouble
- A switch that cycles at the wrong pressure
Ordering pressure switches for Inaruwa
To order pressure switches for Inaruwa, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Nepal are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about pressure switches in Inaruwa
How do I set the cut-out pressure?
Take the value from the equipment manual for the refrigerant in use and verify it with a gauge set. Never set a switch above the pressure rating of the components it protects.
What voltage should pressure switches be rated for in Inaruwa?
Nepal supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so pressure switches rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.
How are pressure switches delivered to Inaruwa?
Shipments for Inaruwa normally clear customs at one of the main entry points of Nepal and finish the journey by road; send your delivery address with the enquiry.
Which parts of Inaruwa can I order for?
Enquiries are welcome from every part of Inaruwa. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Inaruwa?
Inaruwa keeps UTC+5:45 all year. At 26.6° N there are about 13 h 49 min of daylight in June and about 10 h 28 min in December.
Which cities near Inaruwa can the same order serve?
The listed cities closest to Inaruwa are Itahari (14 km north-east), Biratnagar (21 km south-east) and Dharan (27 km north-east). Combine them into one order and give each delivery address.
More Klima products for Inaruwa
- Klima Contactors in Inaruwa
- Klima Filter Driers in Inaruwa
- Klima Thermometers for HVAC in Inaruwa
- Klima Transformer for HVAC in Inaruwa
- Klima Delay on Make Timer in Inaruwa
- Klima Temperature Controllers in Inaruwa
Pressure switches in cities near Inaruwa
- Klima Pressure Switches (High & Low) in Itahari (about 14 km)
- Klima Pressure Switches (High & Low) in Biratnagar (about 21 km)
- Klima Pressure Switches (High & Low) in Dharan (about 27 km)
- Klima Pressure Switches (High & Low) in Rajbiraj (about 40 km)
- Klima Pressure Switches (High & Low) in Triyuga (about 49 km)