Palau: Klima Pressure Switches (High & Low)
Home to about 18,000 people, Palau sits in Oceania. Its capital is Melekeok. Across Palau the climate is hot and humid tropical, and conditions are similar from place to place. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
Demand for pressure switches comes mostly from offices, shops and malls, factories and workshops as well as homes and apartments. Klima Industries lists 4 models in this range with full specifications below, and enquiries from Palau are welcome.
- Capital
- Melekeok
- Population
- 18,000
- Area
- 458 km²
- Time zone
- UTC+9 all year
- Climate
- Hot and humid tropical
- Supply
- 120 V, 60 Hz
- Standards
- applicable national electrical-safety and import conformity rules (generally IEC-based)
Klima Pressure Switches (High & Low) models
- Klima High Pressure Switch, Manual Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima High Pressure Switch, Auto Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima Low Pressure Switch, Auto Reset Type: Low pressure, Pressure range: -0.7 to 7 bar, Cut-out setting: Adjustable bar
- Klima Dual Pressure Switch, HP/LP Type: Dual HP/LP, Pressure range: HP 8 to 32, LP -0.7 to 7 bar, Cut-out setting: Adjustable bar
All Klima products for Palau · Klima Pressure Switches (High & Low) overview
Pressure switches and the climate in Palau
In Palau, cooling and refrigeration work in every month of the year. Every minute an open circuit spends in humid air adds moisture, which turns into acid in the oil; fit new pressure switches last and keep the system closed until you are ready to evacuate.
Sun-warmed walls make thermostats read high; place pressure switches on interior walls away from sunlight and supply air so that the set point reflects the room, not the wall.
Palau supplies 120 V at 60 Hz, typically 120/240 V split-phase in homes and 208, 240 or 480 V three-phase in larger buildings, so check the voltage class of pressure switches against the nameplate.
Pressure switches across the cities of Palau
The directory lists one city for Palau: Ngerulmud, although the capital, Melekeok, is not among the listed cities. Orders from anywhere in Palau are best quoted against it. Parts for Palau are best planned around Ngerulmud, which has a hot and humid tropical climate. In Ngerulmud, expect condensation inside enclosures to show first on pressure switches.
How large is Palau, and how is it settled?
The directory puts Palau at about 458 km², the 43rd smallest of its 241 countries, almost exactly the size of the Seychelles (455 km²). With 18,000 residents the average density is 39 per km², so Palau counts as moderately settled, sparser than 73% of the other countries in this directory. The land area is small, so road distances on any one island are short; for island groups, say which island a delivery is for. For scale, Bonaire, Saint Eustatius and Saba has a similar number of people (18,000).
The sun and the clock in Palau
Local time in Ngerulmud is UTC+9 all year.
Sunlight at 7.5° N (Ngerulmud): about 12 h 34 min of daylight in June, about 11 h 41 min in December, and a noon sun that reaches 74° in June and 59° in December. The summer sun is high, so outdoor units in unshaded spots take strong direct heat.
Where pressure switches are used in Palau
Typical work in Palau that needs pressure switches:
- Chillers and air-cooled condensers
- Heat pump outdoor units
- Split, VRF and packaged air conditioners
- Fan speed control by head pressure
- Condensing units and cold rooms
Klima pressure switches models
| Model | Type | Pressure range (bar) | Cut-out setting (bar) |
|---|---|---|---|
| Klima High Pressure Switch, Manual Reset | High pressure | 8 to 32 | Adjustable |
| Klima High Pressure Switch, Auto Reset | High pressure | 8 to 32 | Adjustable |
| Klima Low Pressure Switch, Auto Reset | Low pressure | -0.7 to 7 | Adjustable |
| Klima Dual Pressure Switch, HP/LP | Dual HP/LP | HP 8 to 32, LP -0.7 to 7 | Adjustable |
See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.
Choosing pressure switches for Palau
- Check the electrical rating against the contactor coil or control circuit it will switch.
- Take the setting from the compressor or unit manual and stay below the design pressure of the weakest component.
- Confirm the supply first: Palau uses 120 V at 60 Hz, so check the voltage and frequency rating of pressure switches against the equipment nameplate.
- For hot and humid tropical conditions in Palau, favour sealed, corrosion-resistant construction.
Keeping pressure switches reliable in Palau
- Check that connections are leak-free and that capillary tubes are not kinked.
A tropical climate keeps cooling demand steady through the year in Palau, so there is no quiet season. Schedule checks of pressure switches around the main rainy-season changes and keep spares on hand. Controls drift over time; verify setpoints and switch points before the demanding months.
Faults to watch for
- A unit that does not restart after a trip
Standards and paperwork for pressure switches in Palau
Klima pressure switches are specified against EN 12263 (safety switching devices for limiting pressure in refrigerating systems), IEC 60947-5-1. For import and installation in Palau, buyers also meet applicable national electrical-safety and import conformity rules (generally IEC-based). Ask for the datasheet and conformity documents for the Klima model you plan to specify, so that submittals and import paperwork are complete.
Getting pressure switches to Palau
Freight reaches Palau by sea or air through its main entry points and continues by road; tell us your delivery address and preferred route with your enquiry.
The local currency is the Dollar (USD), so confirm the quotation currency and delivery terms before you order. The main languages are Palauan, Sonsorol, English and Tobian; this site and its enquiry form are in English.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about pressure switches in Palau
How do I set the cut-out pressure?
Take the value from the equipment manual for the refrigerant in use and verify it with a gauge set. Never set a switch above the pressure rating of the components it protects.
What voltage should pressure switches be rated for in Palau?
The supply in Palau is 120 V, 60 Hz. Residential units usually run on split-phase and commercial plant on three-phase, so confirm the voltage and phase before choosing a pressure switch.
Which standards apply to pressure switches in Palau?
Klima pressure switches follow EN 12263 (safety switching devices for limiting pressure in refrigerating systems), IEC 60947-5-1. In Palau the local framework is applicable national electrical-safety and import conformity rules (generally IEC-based); request the datasheet and conformity documents with your enquiry.
How are pressure switches delivered to Palau?
Freight reaches Palau by sea or air through its main entry points and continues by road; tell us your delivery address and preferred route with your enquiry.
Which city in Palau can I order pressure switches for?
Ngerulmud is the one city listed for Palau, and enquiries from anywhere in the country are welcome; give the delivery address with your enquiry.
What local time and daylight should I plan for in Palau?
Ngerulmud keeps UTC+9 all year. At 7.5° N there are about 12 h 34 min of daylight in June and about 11 h 41 min in December.
More Klima products for Palau
- Klima Contactors in Palau
- Klima Filter Driers in Palau
- Klima Thermometers for HVAC in Palau
- Klima Thermostat Guards in Palau
- Klima Flux Powder (100 g & 250 g) in Palau
- Klima Copper Coils & Tubes in Palau