Klima Industries

Pressure switches for Peru

With about 32 million people, Peru is a large national market in South America. Its capital is Lima. Most of the country has a hot and arid climate, and conditions vary by region. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.

The main users of pressure switches in Peru are offices, shops and malls as well as cold stores and food distribution. The Klima range includes 4 models, each with a specification table; send an enquiry from Peru for a quotation.

Capital
Lima
Population
32 million
Area
1,285,220 km²
Time zone
UTC-5 all year
Climate
Hot and arid
Supply
220 V, 60 Hz
Main ports
Callao
Standards
INACAL technical standards (NTP) and national electrical safety rules

Klima Pressure Switches (High & Low) models

All Klima products for Peru · Klima Pressure Switches (High & Low) overview

Pressure switches and the climate in Peru

In Peru, air conditioning and refrigeration run for most of the year. In very hot weather discharge pressure climbs towards the safety limits; check that pressure switches are rated for the refrigerant in use, and keep condensers clean and fans healthy.

Fine dust builds up on sensors and in dials; a soft brush keeps pressure switches reading accurately.

The mains supply in Peru is 220 V, 60 Hz. Some equipment is built for other markets, so confirm the voltage and frequency printed on the nameplate and match the pressure switch to it.

Mapping demand for pressure switches in Peru

From Tacna to Tumbes, the longest straight-line gap between listed cities is about 1,953 km; so freight between the far ends takes days by road and urgent parts often go by air. Lima is both the capital and the largest listed city, with about 7.7 million people, so the capital is also the biggest single market. Climate decides how pressure switches age, and it changes from city to city in Peru: the last column shows what to expect.

CityPeopleClimateWhat wears pressure switches first
Lima7.7 millionhot and aridsensor drift and setpoints creeping
Arequipa1.2 millionhighlandpressure settings that shift with altitude
Trujillo1.1 millionhot and ariddust in enclosures and sticky switches
Huancayo456,000highlandcalibration drift between seasons
Cusco428,000highlandpressure settings that shift with altitude
Chimbote317,000hot and ariddust in enclosures and sticky switches

Local conditions differ across the 31 listed cities (17 hot and arid, 11 highland and 3 hot and humid tropical), and the right part depends on which city it is for.

Peru in numbers

The directory puts Peru at about 1,285,220 km², the 20th largest of its 241 countries, almost exactly the size of Chad (1,284,000 km²). Population density averages 25 people per km² across 32 million residents, which is sparsely settled and sparser than 78% of the other countries in this directory. With long distances between sites, a call-out for a missing part is costly, so keep a small stock of the common ratings. In population it sits close to Malaysia, which has about 31.5 million.

Time zone, sun and daylight in Peru

Local time in Lima is UTC-5 all year.

Lima lies at 12.0° S, 77.0° W. Daylight lasts about 11 h 25 min at the June solstice and about 12 h 50 min in December, with a noon sun 55° and 79° high; the sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat.

Typical uses of pressure switches in Peru

In Peru, these are the jobs that most often call for pressure switches:

  • Refrigerated transport and containers
  • Split, VRF and packaged air conditioners
  • Condensing units and cold rooms
  • Heat pump outdoor units
  • Supermarket racks and display cases

Klima pressure switches models

ModelTypePressure range (bar)Cut-out setting (bar)
Klima High Pressure Switch, Manual ResetHigh pressure8 to 32Adjustable
Klima High Pressure Switch, Auto ResetHigh pressure8 to 32Adjustable
Klima Low Pressure Switch, Auto ResetLow pressure-0.7 to 7Adjustable
Klima Dual Pressure Switch, HP/LPDual HP/LPHP 8 to 32, LP -0.7 to 7Adjustable

See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.

How to pick pressure switches for work in Peru

  • Use an HP switch with manual reset for safety duty and an LP switch with automatic reset for pump-down or control duty.
  • Check the electrical rating against the contactor coil or control circuit it will switch.
  • Confirm the supply first: Peru uses 220 V at 60 Hz, so check the voltage and frequency rating of pressure switches against the equipment nameplate.
  • Ask for the datasheet and the documents your project needs; in Peru that usually means INACAL technical standards (NTP) and national electrical safety rules.

Keeping pressure switches reliable in Peru

  • Test cut-out and cut-in values with a gauge manifold and nitrogen or a controlled pressure source at commissioning.

In the southern hemisphere the busiest cooling months fall from November to March; September or October is a sensible time to check pressure switches in Peru. Calibrate and test controls under easy conditions so settings are proven before the load rises.

Signs of trouble

  • A unit that does not restart after a trip

Approvals for pressure switches sold into Peru

Klima pressure switches are specified against EN 12263 (safety switching devices for limiting pressure in refrigerating systems), IEC 60947-5-1. For import and installation in Peru, buyers also meet INACAL technical standards (NTP) and national electrical safety rules. Ask for the datasheet and conformity documents for the Klima model you plan to specify, so that submittals and import paperwork are complete.

Supply and delivery to Peru

Sea freight into Peru normally clears through ports such as Callao, with onward delivery by road; urgent parts can travel by air.

The local currency is the Sol (PEN), so confirm the quotation currency and delivery terms before you order. The main languages are Spanish, Quechua and Aymara; this site and its enquiry form are in English.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Questions about pressure switches in Peru

Can I use the same switch for R22 and R410A?

Only if its pressure range and rating cover both. R410A runs at much higher pressures, so check the model list before you order.

What voltage should pressure switches be rated for in Peru?

With 220 V at 60 Hz, Peru needs parts rated for 60 Hz; compare the rated voltage of each pressure switch with the equipment it will serve.

Which standards apply to pressure switches in Peru?

Klima pressure switches follow EN 12263 (safety switching devices for limiting pressure in refrigerating systems), IEC 60947-5-1. In Peru the local framework is INACAL technical standards (NTP) and national electrical safety rules; request the datasheet and conformity documents with your enquiry.

How are pressure switches delivered to Peru?

Cargo for Peru usually arrives through Callao; tell us your preferred port or delivery address with your enquiry.

Which cities in Peru can I order pressure switches for?

Every listed city is covered. The largest are Lima (7.7 million), Arequipa (1.2 million), Trujillo (1.1 million), Piura (630,000) and Chiclayo (609,000). The country page lists the rest.

Do the neighbours of Peru use the same mains supply?

No. The supply next door is different: Ecuador (120 V, 60 Hz), Chile (230 V, 50 Hz), Bolivia (230 V, 50 Hz) and 2 more. Check the voltage and frequency of the destination before ordering parts for use across the border.

What local time and daylight should I plan for in Peru?

Lima keeps UTC-5 all year. At 12.0° S there are about 11 h 25 min of daylight in June and about 12 h 50 min in December.

More Klima products for Peru

Pressure switches in cities across Peru