Klima Industries

Buying pressure switches in the Philippines

With about 106.7 million people, the Philippines is one of the largest national markets in the world in Asia. Its capital is Manila. The prevailing climate is hot and humid tropical, though conditions differ between regions. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.

Pressure switches are bought here mainly for offices, shops and malls as well as factories and workshops. Klima Industries lists 4 models in this range with full specifications below, and enquiries from the Philippines are welcome.

Capital
Manila
Population
106.7 million
Area
300,000 km²
Time zone
UTC+8 all year
Climate
Hot and humid tropical
Supply
220 V, 60 Hz
Main ports
Manila International Container Terminal, Cebu Port, Davao Port
Standards
PNS / BPS certification for regulated products

Klima Pressure Switches (High & Low) models

All Klima products for the Philippines · Klima Pressure Switches (High & Low) overview

Conditions in the Philippines that affect pressure switches

In the Philippines, cooling and refrigeration work in every month of the year. Humid air makes moisture ingress the biggest installation risk, so keep pressure switches sealed until use, braze under nitrogen and evacuate to a deep vacuum before charging.

In very hot weather a badly placed control keeps the compressor running; mount pressure switches out of direct sun and away from heat sources.

The mains supply in the Philippines is 220 V, 60 Hz. Some equipment is built for other markets, so confirm the voltage and frequency printed on the nameplate and match the pressure switch to it.

Cities that buy pressure switches in the Philippines

The largest listed city is Quezon City, not the capital: Manila is roughly 9 km to its south-west, and orders should name the right one. From General Santos to Baguio, the longest straight-line gap between listed cities is about 1,249 km; so delivery to the far end of the country is a long road journey. The table lists the largest cities in the Philippines with the climate stress that wears pressure switches fastest in each.

CityPeopleClimateWhat wears pressure switches first
Quezon City3.1 millionhot and humid tropicalcondensation inside enclosures
Davao1.8 millionhot and humid tropicalcondensation inside enclosures
Caloocan1.7 millionhot and humid tropicalsensor drift and setpoints creeping
Budta1.3 millionhot and humid tropicalcondensation inside enclosures
Zamboanga1 millionhot and humid tropicalsensor drift and setpoints creeping
Cebu City965,000hot and humid tropicalcondensation inside enclosures

The sun and the clock in the Philippines

Manila keeps UTC+8 all year.

Manila lies at 14.6° N, 121.0° E. Daylight lasts about 12 h 59 min at the June solstice and about 11 h 16 min in December, with a noon sun 81° and 52° high; the sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat.

The Philippines in numbers

At roughly 300,000 km², the Philippines is the 72nd largest of the 241 countries covered by this directory, almost exactly the size of Italy (301,230 km²). Its 106.7 million people give an average of 356 per km². In this directory that is densely settled, denser than 85% of the other countries in this directory. Most sites sit within reach of a city, so deliveries can usually be planned city by city. Its population is similar to that of Ethiopia (109.2 million).

Jobs in the Philippines that call for pressure switches

Pressure switches are most often specified in the Philippines for:

  • Split, VRF and packaged air conditioners
  • Supermarket racks and display cases
  • Refrigerated transport and containers
  • Condensing units and cold rooms
  • Heat pump outdoor units

Klima pressure switches models

ModelTypePressure range (bar)Cut-out setting (bar)
Klima High Pressure Switch, Manual ResetHigh pressure8 to 32Adjustable
Klima High Pressure Switch, Auto ResetHigh pressure8 to 32Adjustable
Klima Low Pressure Switch, Auto ResetLow pressure-0.7 to 7Adjustable
Klima Dual Pressure Switch, HP/LPDual HP/LPHP 8 to 32, LP -0.7 to 7Adjustable

See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.

Choosing pressure switches for the Philippines

  • Take the setting from the compressor or unit manual and stay below the design pressure of the weakest component.
  • Choose the refrigerant and its pressure range first, because cut-out values for R410A differ greatly from those for R22 or R134a.
  • Confirm the supply first: the Philippines uses 220 V at 60 Hz, so check the voltage and frequency rating of pressure switches against the equipment nameplate.
  • Ask for the datasheet and the documents your project needs; in the Philippines that usually means PNS / BPS certification for regulated products.

Care and maintenance in the Philippines

  • Test cut-out and cut-in values with a gauge manifold and nitrogen or a controlled pressure source at commissioning.

With little seasonal change in temperature, air conditioning in the Philippines works almost every day. Spread checks of pressure switches through the year instead of waiting for a peak. Controls drift over time; verify setpoints and switch points before the demanding months.

Signs of trouble

  • A switch that cycles at the wrong pressure

Standards and paperwork for pressure switches in the Philippines

Klima pressure switches follow EN 12263 (safety switching devices for limiting pressure in refrigerating systems), IEC 60947-5-1; in the Philippines expect PNS / BPS certification for regulated products as well. Request the datasheet and test documents with your enquiry so the paperwork is ready before the goods ship.

Supply and delivery to the Philippines

Sea freight into the Philippines normally clears through ports such as Manila International Container Terminal, Cebu Port and Davao Port, with onward delivery by road; urgent parts can travel by air.

The local currency is the Peso (PHP), so confirm the quotation currency and delivery terms before you order. The main languages are Tagalog, English, Filipino and Cebuano; this site and its enquiry form are in English.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Questions about pressure switches in the Philippines

What does a high pressure switch do?

It opens the control circuit if discharge pressure rises above a set limit, which stops the compressor before the pressure can damage it or the pipework.

What voltage should pressure switches be rated for in the Philippines?

With 220 V at 60 Hz, the Philippines needs parts rated for 60 Hz; compare the rated voltage of each pressure switch with the equipment it will serve.

Which standards apply to pressure switches in the Philippines?

Klima pressure switches follow EN 12263 (safety switching devices for limiting pressure in refrigerating systems), IEC 60947-5-1. In the Philippines the local framework is PNS / BPS certification for regulated products; request the datasheet and conformity documents with your enquiry.

How are pressure switches delivered to the Philippines?

Cargo for the Philippines usually arrives through Manila International Container Terminal, Cebu Port and Davao Port; tell us your preferred port or delivery address with your enquiry.

Which cities in the Philippines can I order pressure switches for?

Every listed city is covered. The largest are Quezon City (3.1 million), Davao (1.8 million), Caloocan (1.7 million), Manila (1.6 million) and Taguig (1.3 million). The country page lists the rest.

What local time and daylight should I plan for in the Philippines?

Manila keeps UTC+8 all year. At 14.6° N there are about 12 h 59 min of daylight in June and about 11 h 16 min in December.

More Klima products for the Philippines

Pressure switches in cities across the Philippines