Klima Pressure Switches (High & Low) in Owando
With about 36,000 people, Owando is a smaller city in the Republic of the Congo. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
The main users of pressure switches in Owando are offices, shops and malls as well as factories and workshops. The Klima range includes 4 models, each with a specification table; send an enquiry from Owando for a quotation.
- Country
- Republic of the Congo
- Population
- 36,000
- Climate
- Hot and humid tropical
- Coordinates
- 0.5° S, 15.9° E
- Time zone
- UTC+1 all year
- From Brazzaville
- 426 km north
- Supply
- 230 V, 50 Hz
Klima Pressure Switches (High & Low) models
- Klima High Pressure Switch, Manual Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima High Pressure Switch, Auto Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima Low Pressure Switch, Auto Reset Type: Low pressure, Pressure range: -0.7 to 7 bar, Cut-out setting: Adjustable bar
- Klima Dual Pressure Switch, HP/LP Type: Dual HP/LP, Pressure range: HP 8 to 32, LP -0.7 to 7 bar, Cut-out setting: Adjustable bar
All Klima products for Owando · Klima Pressure Switches (High & Low) overview
Pressure switches and the climate in Owando
In Owando, cooling and refrigeration work in every month of the year. Humid air makes moisture ingress the biggest installation risk, so keep pressure switches sealed until use, braze under nitrogen and evacuate to a deep vacuum before charging.
In very hot weather a badly placed control keeps the compressor running; mount pressure switches out of direct sun and away from heat sources.
Cities around Owando that need pressure switches
By population Owando is 8th of the 17 cities listed for the Republic of the Congo, with roughly 1% of their combined population, about 1.8% of the size of Brazzaville, the largest. The capital, Brazzaville, is about 426 km away, to the south of Owando. It is about the same size as Puntarenas in Costa Rica, which has 36,000.
Nearest to Owando: Makoua (62 km north-west), Oyo (76 km south) and Mossaka (129 km south-east). Two other listed cities lie within 100 km, and five within 300 km. The farthest listed city in the Republic of the Congo is Pointe-Noire, about 655 km south-west of Owando.
| City | Distance | People | What wears pressure switches first |
|---|---|---|---|
| Makoua | 62 km north-west | 21,000 | sensor drift and setpoints creeping |
| Oyo | 76 km south | 21,000 | condensation inside enclosures |
| Mossaka | 129 km south-east | 22,000 | condensation inside enclosures |
| Gamboma | 155 km south | 27,000 | sensor drift and setpoints creeping |
| Ouesso | 234 km north | 41,000 | condensation inside enclosures |
| Impfondo | 335 km north-east | 49,000 | condensation inside enclosures |
In a smaller city like Owando, a replacement control can mean a long wait. Keep a spare for critical equipment and check that the range matches the original.
Daylight and sun angle in Owando
The clock in Owando follows UTC+1 all year.
At 0.5° S, Owando has about 12 h 06 min of daylight at the June solstice and about 12 h 09 min at the December solstice. The noon sun stands 66° above the horizon in June and 67° in December, and the summer sun is high, so outdoor units in unshaded spots take strong direct heat. The climate in Owando is hot and humid tropical, in line with the rest of the Republic of the Congo; 16 other listed cities share it.
Jobs in Owando that call for pressure switches
In Owando, these are the jobs that most often call for pressure switches:
- Chillers and air-cooled condensers
- Water-cooled condensers and cooling-tower circuits
- Split, VRF and packaged air conditioners
Klima pressure switches models
| Model | Type | Pressure range (bar) | Cut-out setting (bar) |
|---|---|---|---|
| Klima High Pressure Switch, Manual Reset | High pressure | 8 to 32 | Adjustable |
| Klima High Pressure Switch, Auto Reset | High pressure | 8 to 32 | Adjustable |
| Klima Low Pressure Switch, Auto Reset | Low pressure | -0.7 to 7 | Adjustable |
| Klima Dual Pressure Switch, HP/LP | Dual HP/LP | HP 8 to 32, LP -0.7 to 7 | Adjustable |
See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.
Choosing pressure switches for Owando
- Choose the refrigerant and its pressure range first, because cut-out values for R410A differ greatly from those for R22 or R134a.
- For hot and humid tropical conditions in Owando, favour sealed, corrosion-resistant construction.
Keeping pressure switches reliable in Owando
- Test cut-out and cut-in values with a gauge manifold and nitrogen or a controlled pressure source at commissioning.
With little seasonal change in temperature, air conditioning in Owando works almost every day. Spread checks of pressure switches through the year instead of waiting for a peak. Controls drift over time; verify setpoints and switch points before the demanding months.
Faults to watch for
- Frequent unexplained compressor lockouts
Supply and delivery to Owando
To order pressure switches for Owando, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for the Republic of the Congo are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about pressure switches in Owando
What is a dual pressure switch?
One body with both high- and low-pressure sensing and a combined contact, so a single connection protects both sides of the circuit.
What voltage should pressure switches be rated for in Owando?
The mains supply in the Republic of the Congo is 230 V, 50 Hz. Match pressure switches to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
How are pressure switches delivered to Owando?
Shipments for Owando normally clear customs at one of the main entry points of the Republic of the Congo and finish the journey by road; send your delivery address with the enquiry.
Which parts of Owando can I order for?
Enquiries are welcome from every part of Owando. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Owando?
Owando keeps UTC+1 all year. At 0.5° S there are about 12 h 06 min of daylight in June and about 12 h 09 min in December.
Which cities near Owando can the same order serve?
The listed cities closest to Owando are Makoua (62 km north-west), Oyo (76 km south) and Mossaka (129 km south-east). Combine them into one order and give each delivery address.
More Klima products for Owando
- Klima Contactors in Owando
- Klima Filter Driers in Owando
- Klima Thermometers for HVAC in Owando
- Klima Temperature Controllers in Owando
- Klima PVC Tapes in Owando
- Klima Condensate Pump in Owando
Pressure switches in cities near Owando
- Klima Pressure Switches (High & Low) in Makoua (about 62 km)
- Klima Pressure Switches (High & Low) in Oyo (about 76 km)
- Klima Pressure Switches (High & Low) in Mossaka (about 129 km)
- Klima Pressure Switches (High & Low) in Gamboma (about 155 km)
- Klima Pressure Switches (High & Low) in Ouesso (about 234 km)