Klima Industries

Klima Pressure Switches (High & Low) supplied to Kagano

With about 40,000 people, Kagano is a smaller city in Rwanda. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.

Demand for pressure switches comes mostly from offices, shops and malls as well as homes and apartments. The range below has 4 models; send an enquiry with the model code and your delivery address in Kagano.

Country
Rwanda
Population
40,000
Climate
Hot and humid tropical
Coordinates
2.3° S, 29.1° E
Time zone
UTC+2 all year
From Kigali
116 km west
Supply
230 V, 50 Hz

Klima Pressure Switches (High & Low) models

All Klima products for Kagano · Klima Pressure Switches (High & Low) overview

Conditions in Kagano that affect pressure switches

In Kagano, cooling and refrigeration work in every month of the year. Every minute an open circuit spends in humid air adds moisture, which turns into acid in the oil; fit new pressure switches last and keep the system closed until you are ready to evacuate.

In very hot weather a badly placed control keeps the compressor running; mount pressure switches out of direct sun and away from heat sources.

Cities around Kagano that need pressure switches

By population Kagano is 14th of the 22 cities listed for Rwanda, with roughly 1.7% of their combined population, about 3.5% of the size of Kigali, the largest. The capital, Kigali, is about 116 km away, to the east of Kagano. It is about the same size as Charikot in Nepal, which has 40,000.

Nearest to Kagano: Kirambo (6 km north-east), Macuba (12 km north-east) and Karambi (17 km east). 15 other listed cities lie within 100 km, and 21 within 300 km. The farthest listed city in Rwanda is Nyagatare, about 180 km north-east of Kagano.

CityDistancePeopleWhat wears pressure switches first
Kirambo6 km north-east40,000condensation inside enclosures
Macuba12 km north-east33,000sensor drift and setpoints creeping
Karambi17 km east30,000sensor drift and setpoints creeping
Karengera20 km south33,000sensor drift and setpoints creeping
Gihombo21 km north-east30,000sensor drift and setpoints creeping
Cyangugu26 km south-west44,000sensor drift and setpoints creeping

In a smaller city like Kagano, a replacement control can mean a long wait. Keep a spare for critical equipment and check that the range matches the original.

Time zone, sun and daylight in Kagano

The clock in Kagano follows UTC+2 all year.

Sunlight at 2.3° S (Kagano): about 11 h 59 min of daylight in June, about 12 h 15 min in December, and a noon sun that reaches 64° in June and 69° in December. The summer sun is high, so outdoor units in unshaded spots take strong direct heat. Unlike the highland country as a whole, Kagano is hot and humid tropical; 20 other listed cities share it.

Jobs in Kagano that call for pressure switches

Pressure switches are most often specified in Kagano for:

  • Heat pump outdoor units
  • Split, VRF and packaged air conditioners
  • Supermarket racks and display cases

Klima pressure switches models

ModelTypePressure range (bar)Cut-out setting (bar)
Klima High Pressure Switch, Manual ResetHigh pressure8 to 32Adjustable
Klima High Pressure Switch, Auto ResetHigh pressure8 to 32Adjustable
Klima Low Pressure Switch, Auto ResetLow pressure-0.7 to 7Adjustable
Klima Dual Pressure Switch, HP/LPDual HP/LPHP 8 to 32, LP -0.7 to 7Adjustable

See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.

Selecting pressure switches in Kagano

  • Choose the refrigerant and its pressure range first, because cut-out values for R410A differ greatly from those for R22 or R134a.
  • Confirm the supply first: Rwanda uses 230 V at 50 Hz, so check the voltage and frequency rating of pressure switches against the equipment nameplate.

Care and maintenance in Kagano

  • Test cut-out and cut-in values with a gauge manifold and nitrogen or a controlled pressure source at commissioning.

A tropical climate keeps cooling demand steady through the year in Kagano, so there is no quiet season. Schedule checks of pressure switches around the main rainy-season changes and keep spares on hand. Checking setpoints and safety cut-outs in a quiet week is simpler than doing it during a heatwave.

Signs of trouble

  • A unit that does not restart after a trip

Getting pressure switches to Kagano

Shipments for Kagano normally clear customs at one of the main entry points of Rwanda and finish the journey by road; send your delivery address with the enquiry.

National rules, standards and voltage for Rwanda are summarised on the country page.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Questions about pressure switches in Kagano

Can I use the same switch for R22 and R410A?

Only if its pressure range and rating cover both. R410A runs at much higher pressures, so check the model list before you order.

What voltage should pressure switches be rated for in Kagano?

With a 230 V, 50 Hz supply, Rwanda follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every pressure switch against the equipment it serves.

How are pressure switches delivered to Kagano?

To order pressure switches for Kagano, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

Which parts of Kagano can I order for?

Enquiries are welcome from every part of Kagano. Send the delivery address with your enquiry.

Which cities near Kagano can the same order serve?

The listed cities closest to Kagano are Kirambo (6 km north-east), Macuba (12 km north-east) and Karambi (17 km east). Combine them into one order and give each delivery address.

What local time and daylight should I plan for in Kagano?

Kagano keeps UTC+2 all year. At 2.3° S there are about 11 h 59 min of daylight in June and about 12 h 15 min in December.

More Klima products for Kagano

Pressure switches in cities near Kagano