Klima Pressure Switches (High & Low) in Yanbu
Found in Saudi Arabia, Yanbu is a smaller city with a hot and arid climate. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.
Demand for pressure switches comes mostly from offices, shops and malls, factories and workshops as well as cold stores and food distribution. The Klima range includes 4 models, each with a specification table; send an enquiry from Yanbu for a quotation.
- Country
- Saudi Arabia
- Population
- 200,000
- Climate
- Hot and arid
- Coordinates
- 24.1° N, 38.1° E
- Time zone
- UTC+3 all year
- From Riyadh
- 879 km west
- Supply
- 127/220 V, 60 Hz
Klima Pressure Switches (High & Low) models
- Klima High Pressure Switch, Manual Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima High Pressure Switch, Auto Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima Low Pressure Switch, Auto Reset Type: Low pressure, Pressure range: -0.7 to 7 bar, Cut-out setting: Adjustable bar
- Klima Dual Pressure Switch, HP/LP Type: Dual HP/LP, Pressure range: HP 8 to 32, LP -0.7 to 7 bar, Cut-out setting: Adjustable bar
All Klima products for Yanbu · Klima Pressure Switches (High & Low) overview
What Yanbu demands of pressure switches
In Yanbu, air conditioning and refrigeration run for most of the year. In very hot weather discharge pressure climbs towards the safety limits; check that pressure switches are rated for the refrigerant in use, and keep condensers clean and fans healthy.
Fine dust builds up on sensors and in dials; a soft brush keeps pressure switches reading accurately.
Where pressure switches go from Yanbu
By population Yanbu is 20th of the 31 cities listed for Saudi Arabia, with roughly 1% of their combined population, about 4.3% of the size of Jeddah, the largest. From Riyadh, the capital, Yanbu is roughly 879 km to the west. It is about the same size as Kamina in DR Congo, which has 200,000.
Nearest to Yanbu: Medina (163 km east), Jeddah (311 km south) and Mecca (347 km south-east). No other listed city lies within 100 km, and one lies within 300 km. At the other extreme, Khobar is about 1,246 km east of Yanbu, the furthest listed city in Saudi Arabia.
| City | Distance | People | What wears pressure switches first |
|---|---|---|---|
| Medina | 163 km east | 1.3 million | sensor drift and setpoints creeping |
| Jeddah | 311 km south | 4.7 million | sensor drift and setpoints creeping |
| Mecca | 347 km south-east | 1.6 million | dust in enclosures and sticky switches |
| Ta'if | 396 km south-east | 689,000 | dust in enclosures and sticky switches |
| Tabuk | 502 km north | 667,000 | dust in enclosures and sticky switches |
| Ha'il | 527 km north-east | 606,000 | sensor drift and setpoints creeping |
In a smaller city like Yanbu, a replacement control can mean a long wait. Keep a spare for critical equipment and check that the range matches the original.
The sun and the clock in Yanbu
Yanbu keeps UTC+3 all year.
Yanbu lies at 24.1° N, 38.1° E. Daylight lasts about 13 h 38 min at the June solstice and about 10 h 39 min in December, with a noon sun 89° and 42° high; at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. The climate in Yanbu is hot and arid, in line with the rest of Saudi Arabia; 30 other listed cities share it.
Where pressure switches are used in Yanbu
In Yanbu, these are the jobs that most often call for pressure switches:
- Split, VRF and packaged air conditioners
- Chillers and air-cooled condensers
- Heat pump outdoor units
Klima pressure switches models
| Model | Type | Pressure range (bar) | Cut-out setting (bar) |
|---|---|---|---|
| Klima High Pressure Switch, Manual Reset | High pressure | 8 to 32 | Adjustable |
| Klima High Pressure Switch, Auto Reset | High pressure | 8 to 32 | Adjustable |
| Klima Low Pressure Switch, Auto Reset | Low pressure | -0.7 to 7 | Adjustable |
| Klima Dual Pressure Switch, HP/LP | Dual HP/LP | HP 8 to 32, LP -0.7 to 7 | Adjustable |
See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.
Selecting pressure switches in Yanbu
- Take the setting from the compressor or unit manual and stay below the design pressure of the weakest component.
- Ask for the datasheet and the documents your project needs; in Saudi Arabia that usually means SASO / SABER conformity certificates and GSO standards.
Keeping pressure switches reliable in Yanbu
- Test cut-out and cut-in values with a gauge manifold and nitrogen or a controlled pressure source at commissioning.
In the northern hemisphere the busiest cooling months fall from May to September; March or April is a sensible time to check pressure switches in Yanbu. Controls drift over time; verify setpoints and switch points before the demanding months.
Faults to watch for
- A switch that cycles at the wrong pressure
Ordering pressure switches for Yanbu
Shipments for Yanbu normally clear customs at one of the main entry points of Saudi Arabia and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Saudi Arabia are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about pressure switches in Yanbu
Can I use the same switch for R22 and R410A?
Only if its pressure range and rating cover both. R410A runs at much higher pressures, so check the model list before you order.
What voltage should pressure switches be rated for in Yanbu?
Saudi Arabia uses 127/220 V at 60 Hz, so check that pressure switches are rated for that voltage and for 60 Hz operation before you order.
How are pressure switches delivered to Yanbu?
To order pressure switches for Yanbu, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Yanbu can I order for?
Enquiries are welcome from every part of Yanbu. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Yanbu?
Yanbu keeps UTC+3 all year. At 24.1° N there are about 13 h 38 min of daylight in June and about 10 h 39 min in December.
Which cities near Yanbu can the same order serve?
The listed cities closest to Yanbu are Medina (163 km east), Jeddah (311 km south) and Mecca (347 km south-east). Combine them into one order and give each delivery address.
More Klima products for Yanbu
- Klima Contactors in Yanbu
- Klima Filter Driers in Yanbu
- Klima Thermometers for HVAC in Yanbu
- Klima PVC Tapes in Yanbu
- Klima Thermostats in Yanbu
- Klima Thermostat Guards in Yanbu
Pressure switches in cities near Yanbu
- Klima Pressure Switches (High & Low) in Medina (about 163 km)
- Klima Pressure Switches (High & Low) in Jeddah (about 311 km)
- Klima Pressure Switches (High & Low) in Mecca (about 347 km)
- Klima Pressure Switches (High & Low) in Ta'if (about 396 km)
- Klima Pressure Switches (High & Low) in Tabuk (about 502 km)