Klima Industries

Pressure switches supply in Chungju

Chungju is a smaller city in South Korea. The climate is continental. Summers are warm to hot and winters are cold, with a wide swing between the seasons.

The main users of pressure switches in Chungju are offices, shops and malls, factories and workshops as well as cold stores and food distribution. The Klima range includes 4 models, each with a specification table; send an enquiry from Chungju for a quotation.

Country
South Korea
Population
209,000
Climate
Continental
Coordinates
37.0° N, 127.9° E
Time zone
UTC+9 all year
From Seoul
107 km south-east
Supply
220 V, 60 Hz

Klima Pressure Switches (High & Low) models

All Klima products for Chungju · Klima Pressure Switches (High & Low) overview

Conditions in Chungju that affect pressure switches

In Chungju, cooling peaks in a short, hot summer, and sub-zero spells are normal in winter. Wide temperature swings move rigid pipework; leave bends and clips that let the line flex, and check pressure switches connections for slow leaks each season.

For low-temperature duty, confirm that the range of pressure switches reaches below the coldest set point you need, and keep batteries fresh.

Cities around Chungju that need pressure switches

Among the 37 listed cities in South Korea, Chungju comes 34th by population, with about 0.6% of the listed urban population, roughly 2% of the size of the largest city, Seoul. The capital, Seoul, is about 107 km away, to the north-west of Chungju. It is about the same size as Kanggye in North Korea, which has 210,000.

In the directory the nearest cities are Wonju (42 km north), Cheongju-si (54 km south-west) and Icheon-si (55 km north-west). Nine other listed cities lie within 100 km, and 35 within 300 km.

CityDistancePeopleWhat wears pressure switches first
Wonju42 km north333,000calibration drift between seasons
Cheongju-si54 km south-west852,000calibration drift between seasons
Icheon-si55 km north-west196,000calibration drift between seasons
Sejong71 km south-west395,000calibration drift between seasons
Cheonan72 km west659,000slow response and frozen sensing bulbs
Pyeongtaek75 km west365,000slow response and frozen sensing bulbs

In a smaller city like Chungju, a replacement control can mean a long wait. Keep a spare for critical equipment and check that the range matches the original.

The sun and the clock in Chungju

Local time in Chungju is UTC+9 all year.

At 37.0° N, Chungju has about 14 h 42 min of daylight at the June solstice and about 9 h 37 min at the December solstice. The noon sun stands 76° above the horizon in June and 30° in December, and the sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. The climate in Chungju is continental, in line with the rest of South Korea; 19 other listed cities share it.

Typical uses of pressure switches in Chungju

Pressure switches are most often specified in Chungju for:

  • Chillers and air-cooled condensers
  • Split, VRF and packaged air conditioners
  • Refrigerated transport and containers

Klima pressure switches models

ModelTypePressure range (bar)Cut-out setting (bar)
Klima High Pressure Switch, Manual ResetHigh pressure8 to 32Adjustable
Klima High Pressure Switch, Auto ResetHigh pressure8 to 32Adjustable
Klima Low Pressure Switch, Auto ResetLow pressure-0.7 to 7Adjustable
Klima Dual Pressure Switch, HP/LPDual HP/LPHP 8 to 32, LP -0.7 to 7Adjustable

See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.

Selecting pressure switches in Chungju

  • Choose the refrigerant and its pressure range first, because cut-out values for R410A differ greatly from those for R22 or R134a.
  • Confirm the supply first: South Korea uses 220 V at 60 Hz, so check the voltage and frequency rating of pressure switches against the equipment nameplate.

Care and maintenance in Chungju

  • Test cut-out and cut-in values with a gauge manifold and nitrogen or a controlled pressure source at commissioning.

Because Chungju is in the northern hemisphere, the heaviest cooling load normally falls from June to August. Service pressure switches in April or May, while the load is still light. Controls drift over time; verify setpoints and switch points before the demanding months.

Signs of trouble

  • A switch that cycles at the wrong pressure

Getting pressure switches to Chungju

To order pressure switches for Chungju, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

National rules, standards and voltage for South Korea are summarised on the country page.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Questions about pressure switches in Chungju

What does a high pressure switch do?

It opens the control circuit if discharge pressure rises above a set limit, which stops the compressor before the pressure can damage it or the pipework.

What voltage should pressure switches be rated for in Chungju?

With 220 V at 60 Hz, South Korea needs parts rated for 60 Hz; compare the rated voltage of each pressure switch with the equipment it will serve.

How are pressure switches delivered to Chungju?

Shipments for Chungju normally clear customs at one of the main entry points of South Korea and finish the journey by road; send your delivery address with the enquiry.

Which parts of Chungju can I order for?

Enquiries are welcome from every part of Chungju. Send the delivery address with your enquiry.

What local time and daylight should I plan for in Chungju?

Chungju keeps UTC+9 all year. At 37.0° N there are about 14 h 42 min of daylight in June and about 9 h 37 min in December.

Which cities near Chungju can the same order serve?

The listed cities closest to Chungju are Wonju (42 km north), Cheongju-si (54 km south-west) and Icheon-si (55 km north-west). Combine them into one order and give each delivery address.

More Klima products for Chungju

Pressure switches in cities near Chungju