Klima Industries

Buying pressure switches in Port Sudan

With about 490,000 people, Port Sudan is a mid-sized city in Sudan. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.

Demand for pressure switches comes mostly from offices, shops and malls, homes and apartments as well as hospitals and clinics. Klima Industries lists 4 models in this range with full specifications below, and enquiries from Port Sudan are welcome.

Country
Sudan
Population
490,000
Climate
Hot and arid
Coordinates
19.6° N, 37.2° E
Time zone
UTC+2 all year
From Khartoum
671 km north-east
Supply
230 V, 50 Hz

Klima Pressure Switches (High & Low) models

All Klima products for Port Sudan · Klima Pressure Switches (High & Low) overview

Pressure switches and the climate in Port Sudan

In Port Sudan, air conditioning and refrigeration run for most of the year. In very hot weather discharge pressure climbs towards the safety limits; check that pressure switches are rated for the refrigerant in use, and keep condensers clean and fans healthy.

Dust blocks sensor openings and slows response; clean the vents of pressure switches at each service.

Where pressure switches go from Port Sudan

Port Sudan ranks 5th of the 34 listed cities in Sudan and holds about 4.7% of the people living in them, about 25% of the size of Khartoum, the largest. Port Sudan lies about 671 km north-east of Khartoum, the capital. It is about the same size as Ajman in the United Arab Emirates, which has 490,000.

In the directory the nearest cities are Atbara (401 km south-west), Ad-Damir (409 km south-west) and Kassala (471 km south). No other listed city lies within 300 km.

CityDistancePeopleWhat wears pressure switches first
Atbara401 km south-west112,000dust in enclosures and sticky switches
Ad-Damir409 km south-west104,000dust in enclosures and sticky switches
Kassala471 km south401,000sensor drift and setpoints creeping
New Halfa507 km south64,000sensor drift and setpoints creeping
Shendi515 km south-west64,000sensor drift and setpoints creeping
Al Qadarif651 km south364,000sensor drift and setpoints creeping

In a mid-sized city like Port Sudan, specific control ranges can be hard to find. Send the model or nameplate and the range you need so the right one is matched.

Time zone, sun and daylight in Port Sudan

Port Sudan keeps UTC+2 all year.

Sunlight at 19.6° N (Port Sudan): about 13 h 19 min of daylight in June, about 10 h 57 min in December, and a noon sun that reaches 86° in June and 47° in December. The sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. The climate in Port Sudan is hot and arid, in line with the rest of Sudan; 33 other listed cities share it.

Where pressure switches are used in Port Sudan

Typical work in Port Sudan that needs pressure switches:

  • Split, VRF and packaged air conditioners
  • Heat pump outdoor units
  • Condensing units and cold rooms

Klima pressure switches models

ModelTypePressure range (bar)Cut-out setting (bar)
Klima High Pressure Switch, Manual ResetHigh pressure8 to 32Adjustable
Klima High Pressure Switch, Auto ResetHigh pressure8 to 32Adjustable
Klima Low Pressure Switch, Auto ResetLow pressure-0.7 to 7Adjustable
Klima Dual Pressure Switch, HP/LPDual HP/LPHP 8 to 32, LP -0.7 to 7Adjustable

See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.

How to pick pressure switches for work in Port Sudan

  • Take the setting from the compressor or unit manual and stay below the design pressure of the weakest component.
  • Confirm the supply first: Sudan uses 230 V at 50 Hz, so check the voltage and frequency rating of pressure switches against the equipment nameplate.

Care and maintenance in Port Sudan

  • Check that connections are leak-free and that capillary tubes are not kinked.

In the northern hemisphere the busiest cooling months fall from May to September; March or April is a sensible time to check pressure switches in Port Sudan. Controls drift over time; verify setpoints and switch points before the demanding months.

Faults to watch for

  • A switch that cycles at the wrong pressure

Getting pressure switches to Port Sudan

To order pressure switches for Port Sudan, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

National rules, standards and voltage for Sudan are summarised on the country page.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Questions about pressure switches in Port Sudan

What does a low pressure switch do?

It stops the compressor when suction pressure falls too low, protecting it from running with too little refrigerant and preventing evaporator icing.

What voltage should pressure switches be rated for in Port Sudan?

With a 230 V, 50 Hz supply, Sudan follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every pressure switch against the equipment it serves.

How are pressure switches delivered to Port Sudan?

Shipments for Port Sudan normally clear customs at one of the main entry points of Sudan and finish the journey by road; send your delivery address with the enquiry.

Which parts of Port Sudan can I order for?

Enquiries are welcome from every part of Port Sudan. Send the delivery address with your enquiry.

Which cities near Port Sudan can the same order serve?

The listed cities closest to Port Sudan are Atbara (401 km south-west), Ad-Damir (409 km south-west) and Kassala (471 km south). Combine them into one order and give each delivery address.

What local time and daylight should I plan for in Port Sudan?

Port Sudan keeps UTC+2 all year. At 19.6° N there are about 13 h 19 min of daylight in June and about 10 h 57 min in December.

More Klima products for Port Sudan

Pressure switches in cities near Port Sudan