Klima Industries

Gavle: Klima Pressure Switches (High & Low)

Found in Sweden, Gavle is a smaller city with a cold climate. Summers are short and mild, and winters are long and often well below freezing.

The main users of pressure switches in Gavle are offices, shops and malls, factories and workshops as well as cold stores and food distribution. The range below has 4 models; send an enquiry with the model code and your delivery address in Gavle.

Country
Sweden
Population
75,000
Climate
Cold
Coordinates
60.7° N, 17.1° E
Time zone
UTC+1, moving to UTC+2 while daylight saving applies
From Stockholm
158 km north
Supply
230 V, 50 Hz

Klima Pressure Switches (High & Low) models

All Klima products for Gavle · Klima Pressure Switches (High & Low) overview

Pressure switches and the climate in Gavle

In Gavle, cooling is mostly for process, commercial and cold-chain needs rather than comfort. In cold weather head pressure can fall too low, so low-ambient controls and correctly set pressure switches matter, and a circuit opened in freezing conditions needs extra care to keep it dry.

Wide temperature variation makes differentials matter; recheck the setting of pressure switches so that the compressor does not short-cycle.

Cities around Gavle that need pressure switches

By population Gavle is 14th of the 21 cities listed for Sweden, with roughly 1.8% of their combined population, roughly 4.9% of the size of the largest city, Stockholm. From Stockholm, the capital, Gavle is roughly 158 km to the north. For scale, Molepolole in Botswana has a similar population (75,000).

In the directory the nearest cities are Uppsala (95 km south), Vasteras (122 km south) and Eskilstuna (150 km south). One other listed city lies within 100 km, and nine within 300 km. At the other extreme, Malmo is about 613 km south-west of Gavle, the furthest listed city in Sweden.

CityDistancePeopleWhat wears pressure switches first
Uppsala95 km south177,000slow response and frozen sensing bulbs
Vasteras122 km south128,000calibration drift between seasons
Eskilstuna150 km south67,000slow response and frozen sensing bulbs
Stockholm158 km south1.5 millionslow response and frozen sensing bulbs
Sodertalje167 km south71,000slow response and frozen sensing bulbs
Orebro189 km south-west156,000slow response and frozen sensing bulbs

In a smaller city like Gavle, a replacement control can mean a long wait. Keep a spare for critical equipment and check that the range matches the original.

The sun and the clock in Gavle

Local time in Gavle is UTC+1, moving to UTC+2 while daylight saving applies.

Gavle lies at 60.7° N, 17.1° E. Daylight lasts about 19 h 08 min at the June solstice and about 5 h 39 min in December, with a noon sun 53° and 6° high; the sun stays lower in the sky, so wind, snow and frost matter more than shade for outdoor units. Gavle has a cold climate, the same as the country as a whole, and 20 other listed cities share it.

Typical uses of pressure switches in Gavle

In Gavle, these are the jobs that most often call for pressure switches:

  • Chillers and air-cooled condensers
  • Condensing units and cold rooms
  • Heat pump outdoor units

Klima pressure switches models

ModelTypePressure range (bar)Cut-out setting (bar)
Klima High Pressure Switch, Manual ResetHigh pressure8 to 32Adjustable
Klima High Pressure Switch, Auto ResetHigh pressure8 to 32Adjustable
Klima Low Pressure Switch, Auto ResetLow pressure-0.7 to 7Adjustable
Klima Dual Pressure Switch, HP/LPDual HP/LPHP 8 to 32, LP -0.7 to 7Adjustable

See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.

Choosing pressure switches for Gavle

  • Use an HP switch with manual reset for safety duty and an LP switch with automatic reset for pump-down or control duty.
  • Confirm the supply first: Sweden uses 230 V at 50 Hz, so check the voltage and frequency rating of pressure switches against the equipment nameplate.

Keeping pressure switches reliable in Gavle

  • Test cut-out and cut-in values with a gauge manifold and nitrogen or a controlled pressure source at commissioning.

Cooling demand in Gavle is concentrated from June to August, but cold stores and heat pumps run all year. Plan checks of pressure switches for April or May and before the cold weather returns. Checking setpoints and safety cut-outs in a quiet week is simpler than doing it during a heatwave.

Signs of trouble

  • A switch that cycles at the wrong pressure

Getting pressure switches to Gavle

To order pressure switches for Gavle, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

National rules, standards and voltage for Sweden are summarised on the country page.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Pressure switches in Gavle: common questions

What does a high pressure switch do?

It opens the control circuit if discharge pressure rises above a set limit, which stops the compressor before the pressure can damage it or the pipework.

What voltage should pressure switches be rated for in Gavle?

The mains supply in Sweden is 230 V, 50 Hz. Match pressure switches to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.

How are pressure switches delivered to Gavle?

Shipments for Gavle normally clear customs at one of the main entry points of Sweden and finish the journey by road; send your delivery address with the enquiry.

Which parts of Gavle can I order for?

Enquiries are welcome from every part of Gavle. Send the delivery address with your enquiry.

Which cities near Gavle can the same order serve?

The listed cities closest to Gavle are Uppsala (95 km south), Vasteras (122 km south) and Eskilstuna (150 km south). Combine them into one order and give each delivery address.

What local time and daylight should I plan for in Gavle?

Gavle keeps UTC+1, moving to UTC+2 while daylight saving applies. At 60.7° N there are about 19 h 08 min of daylight in June and about 5 h 39 min in December.

More Klima products for Gavle

Pressure switches in cities near Gavle