Klima Industries

Klima Pressure Switches (High & Low) supplied to Hamah

With about 461,000 people, Hamah is a mid-sized city in Syria. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.

Pressure switches are bought here mainly for offices, shops and malls as well as factories and workshops. The range below has 4 models; send an enquiry with the model code and your delivery address in Hamah.

Country
Syria
Population
461,000
Climate
Hot and arid
Coordinates
35.1° N, 36.8° E
Time zone
UTC+3 all year
From Damascus
185 km north
Supply
230 V, 50 Hz

Klima Pressure Switches (High & Low) models

All Klima products for Hamah · Klima Pressure Switches (High & Low) overview

What Hamah demands of pressure switches

In Hamah, air conditioning and refrigeration run for most of the year. High ambient temperatures push condensing pressure up, so pressure switches must suit the higher working pressure and the system needs a clean condenser to stay inside its limits.

Fine dust builds up on sensors and in dials; a soft brush keeps pressure switches reading accurately.

Where pressure switches go from Hamah

By population Hamah is 6th of the 24 cities listed for Syria, with roughly 5.4% of their combined population, about 22% of the size of Aleppo, the largest. From Damascus, the capital, Hamah is roughly 185 km to the north. It is about the same size as Yola in Nigeria, which has 460,000.

The closest are As Salamiyah (30 km south-east), Khan Shaykhun (36 km north) and Homs (45 km south). Six other listed cities lie within 100 km, and 18 within 300 km. The farthest listed city in Syria is Al Qamishli, about 455 km north-east of Hamah.

CityDistancePeopleWhat wears pressure switches first
As Salamiyah30 km south-east95,000dust in enclosures and sticky switches
Khan Shaykhun36 km north49,000sensor drift and setpoints creeping
Homs45 km south775,000sensor drift and setpoints creeping
Tartus84 km west458,000dust in enclosures and sticky switches
Idlib90 km north129,000dust in enclosures and sticky switches
Latakia98 km north-west709,000dust in enclosures and sticky switches

In a mid-sized city like Hamah, specific control ranges can be hard to find. Send the model or nameplate and the range you need so the right one is matched.

Time zone, sun and daylight in Hamah

Hamah keeps UTC+3 all year.

Hamah lies at 35.1° N, 36.8° E. Daylight lasts about 14 h 31 min at the June solstice and about 9 h 47 min in December, with a noon sun 78° and 31° high; at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. The climate in Hamah is hot and arid, in line with the rest of Syria; 23 other listed cities share it.

Where pressure switches are used in Hamah

Typical work in Hamah that needs pressure switches:

  • Split, VRF and packaged air conditioners
  • Chillers and air-cooled condensers
  • Heat pump outdoor units

Klima pressure switches models

ModelTypePressure range (bar)Cut-out setting (bar)
Klima High Pressure Switch, Manual ResetHigh pressure8 to 32Adjustable
Klima High Pressure Switch, Auto ResetHigh pressure8 to 32Adjustable
Klima Low Pressure Switch, Auto ResetLow pressure-0.7 to 7Adjustable
Klima Dual Pressure Switch, HP/LPDual HP/LPHP 8 to 32, LP -0.7 to 7Adjustable

See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.

Selecting pressure switches in Hamah

  • Use an HP switch with manual reset for safety duty and an LP switch with automatic reset for pump-down or control duty.
  • For hot and arid conditions in Hamah, favour higher temperature ratings and some margin on every rated value.

Care and maintenance in Hamah

  • Test cut-out and cut-in values with a gauge manifold and nitrogen or a controlled pressure source at commissioning.

Because Hamah is in the northern hemisphere, the heaviest cooling load normally falls from May to September. Service pressure switches in March or April, while the load is still light. Calibrate and test controls under easy conditions so settings are proven before the load rises.

Signs of trouble

  • Frequent unexplained compressor lockouts

Ordering pressure switches for Hamah

To order pressure switches for Hamah, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

National rules, standards and voltage for Syria are summarised on the country page.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Questions about pressure switches in Hamah

Should I choose manual or automatic reset?

Choose manual reset for safety (HP) duty, because it forces a technician to investigate. Automatic reset suits low-pressure control such as pump-down.

What voltage should pressure switches be rated for in Hamah?

Syria supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so pressure switches rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.

How are pressure switches delivered to Hamah?

Shipments for Hamah normally clear customs at one of the main entry points of Syria and finish the journey by road; send your delivery address with the enquiry.

Which parts of Hamah can I order for?

Enquiries are welcome from every part of Hamah. Send the delivery address with your enquiry.

Which cities near Hamah can the same order serve?

The listed cities closest to Hamah are As Salamiyah (30 km south-east), Khan Shaykhun (36 km north) and Homs (45 km south). Combine them into one order and give each delivery address.

What local time and daylight should I plan for in Hamah?

Hamah keeps UTC+3 all year. At 35.1° N there are about 14 h 31 min of daylight in June and about 9 h 47 min in December.

More Klima products for Hamah

Pressure switches in cities near Hamah