Buying pressure switches in Denver
Denver is a mid-sized city in the United States (Colorado). The climate is continental. Summers are warm to hot and winters are cold, with a wide swing between the seasons.
Pressure switches are bought here mainly for offices, shops and malls as well as factories and workshops. The range below has 4 models; send an enquiry with the model code and your delivery address in Denver.
- Country
- United States
- Population
- 729,000
- Climate
- Continental
- Region
- Colorado
- Coordinates
- 39.7° N, 105.0° W
- Time zone
- UTC-7, moving to UTC-6 while daylight saving applies
- From Washington DC
- 2,396 km west
- Supply
- 120/240 V, 60 Hz
Klima Pressure Switches (High & Low) models
- Klima High Pressure Switch, Manual Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima High Pressure Switch, Auto Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima Low Pressure Switch, Auto Reset Type: Low pressure, Pressure range: -0.7 to 7 bar, Cut-out setting: Adjustable bar
- Klima Dual Pressure Switch, HP/LP Type: Dual HP/LP, Pressure range: HP 8 to 32, LP -0.7 to 7 bar, Cut-out setting: Adjustable bar
All Klima products for Denver · Klima Pressure Switches (High & Low) overview
Conditions in Denver that affect pressure switches
In Denver, cooling peaks in a short, hot summer, and sub-zero spells are normal in winter. Seasonal expansion and contraction stress pipework and joints, so support lines properly and inspect joints near pressure switches for oil traces after the first hot and the first cold spells.
Cold weather calls for the right defrost and low-ambient settings, and for pressure switches whose range reaches the temperatures you need.
Where pressure switches go from Denver
Among the 60 listed cities in the United States, Denver comes 19th by population, with about 1.3% of the listed urban population, roughly 8.3% of the size of the largest city, New York. Denver lies about 2,396 km west of Washington DC, the capital. For scale, Akure in Nigeria has a similar population (730,000).
The closest are Aurora (13 km east), Colorado Springs (102 km south) and Albuquerque (538 km south). One other listed city lies within 100 km, and two within 300 km. At the other extreme, Honolulu is about 5,375 km west of Denver, the furthest listed city in the United States.
| City | Distance | People | What wears pressure switches first |
|---|---|---|---|
| Aurora | 13 km east | 359,000 | calibration drift between seasons |
| Colorado Springs | 102 km south | 457,000 | calibration drift between seasons |
| Albuquerque | 538 km south | 565,000 | dust in enclosures and sticky switches |
| Wichita | 701 km east | 396,000 | slow response and frozen sensing bulbs |
| Omaha | 783 km east | 486,000 | calibration drift between seasons |
| Oklahoma City | 811 km south-east | 681,000 | condensation inside enclosures |
In a mid-sized city like Denver, specific control ranges can be hard to find. Send the model or nameplate and the range you need so the right one is matched.
Time zone, sun and daylight in Denver
Denver keeps UTC-7, moving to UTC-6 while daylight saving applies. It is 2 hours behind Washington DC, which matters when you arrange a call or a delivery window.
Sunlight at 39.7° N (Denver): about 14 h 59 min of daylight in June, about 9 h 21 min in December, and a noon sun that reaches 74° in June and 27° in December. The summer sun is high, so outdoor units in unshaded spots take strong direct heat. Unlike the temperate country as a whole, Denver is continental; 11 other listed cities share it.
Typical uses of pressure switches in Denver
Typical work in Denver that needs pressure switches:
- Split, VRF and packaged air conditioners
- Chillers and air-cooled condensers
- Condensing units and cold rooms
Klima pressure switches models
| Model | Type | Pressure range (bar) | Cut-out setting (bar) |
|---|---|---|---|
| Klima High Pressure Switch, Manual Reset | High pressure | 8 to 32 | Adjustable |
| Klima High Pressure Switch, Auto Reset | High pressure | 8 to 32 | Adjustable |
| Klima Low Pressure Switch, Auto Reset | Low pressure | -0.7 to 7 | Adjustable |
| Klima Dual Pressure Switch, HP/LP | Dual HP/LP | HP 8 to 32, LP -0.7 to 7 | Adjustable |
See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.
Choosing pressure switches for Denver
- Take the setting from the compressor or unit manual and stay below the design pressure of the weakest component.
- Ask for the datasheet and the documents your project needs; in the United States that usually means UL / ETL listing where applicable, National Electrical Code (NEC) wiring rules and EPA refrigerant-handling requirements.
Care and maintenance in Denver
- Check that connections are leak-free and that capillary tubes are not kinked.
In the northern hemisphere the busiest cooling months fall from June to August; April or May is a sensible time to check pressure switches in Denver. Calibrate and test controls under easy conditions so settings are proven before the load rises.
Faults to watch for
- Frequent unexplained compressor lockouts
Ordering pressure switches for Denver
Shipments for Denver normally clear customs at one of the main entry points of the United States and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for the United States are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Pressure switches in Denver: common questions
What does a high pressure switch do?
It opens the control circuit if discharge pressure rises above a set limit, which stops the compressor before the pressure can damage it or the pipework.
What voltage should pressure switches be rated for in Denver?
The United States supplies 120/240 V at 60 Hz, typically 120/240 V split-phase in homes and 208, 240 or 480 V three-phase in larger buildings, so check the voltage class of pressure switches against the nameplate.
How are pressure switches delivered to Denver?
To order pressure switches for Denver, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Denver can I order for?
Enquiries are welcome from every part of Denver. Send the delivery address with your enquiry.
Which cities near Denver can the same order serve?
The listed cities closest to Denver are Aurora (13 km east), Colorado Springs (102 km south) and Albuquerque (538 km south). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Denver?
Denver keeps UTC-7, moving to UTC-6 while daylight saving applies. At 39.7° N there are about 14 h 59 min of daylight in June and about 9 h 21 min in December.
More Klima products for Denver
- Klima Contactors in Denver
- Klima Filter Driers in Denver
- Klima Thermometers for HVAC in Denver
- Klima Temperature Controllers in Denver
- Klima Cables (3 & 4 Core) in Denver
- Klima Condensate Pump in Denver
Pressure switches in cities near Denver
- Klima Pressure Switches (High & Low) in Aurora (about 13 km)
- Klima Pressure Switches (High & Low) in Colorado Springs (about 102 km)
- Klima Pressure Switches (High & Low) in Albuquerque (about 538 km)
- Klima Pressure Switches (High & Low) in Wichita (about 701 km)
- Klima Pressure Switches (High & Low) in Omaha (about 783 km)