Klima HVAC transformers for Dar
Dar is a smaller city in Cambodia. The climate is hot and humid tropical. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
Demand for HVAC transformers comes mostly from offices, shops and malls as well as factories and workshops. The Klima range includes 4 models, each with a specification table; send an enquiry from Dar for a quotation.
- Country
- Cambodia
- Population
- 23,000
- Climate
- Hot and humid tropical
- Coordinates
- 11.8° N, 106.1° E
- Time zone
- UTC+7 all year
- From Phnom Penh
- 131 km east
- Supply
- 230 V, 50 Hz
Klima Transformer for HVAC models
- Klima HVAC Transformer 230 V to 24 V, 40 VA Primary voltage: 230 V, Secondary voltage: 24 V AC, Rating: 40 VA
- Klima HVAC Transformer 110 V to 24 V, 40 VA Primary voltage: 110/120 V, Secondary voltage: 24 V AC, Rating: 40 VA
- Klima HVAC Transformer 230 V to 24 V, 75 VA Primary voltage: 230 V, Secondary voltage: 24 V AC, Rating: 75 VA
- Klima HVAC Transformer 400 V to 24 V, 100 VA Primary voltage: 380/400 V, Secondary voltage: 24 V AC, Rating: 100 VA
All Klima products for Dar · Klima Transformer for HVAC overview
HVAC transformers and the climate in Dar
In Dar, cooling and refrigeration work in every month of the year. Damp air can track across dirty or unprotected connections; fit HVAC transformers with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Heat is the main enemy of electrical parts here: HVAC transformers run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Where HVAC transformers go from Dar
Dar ranks 23rd of the 24 listed cities in Cambodia and holds about 0.7% of the people living in them, about 1.5% of the size of Phnom Penh, the largest. The capital, Phnom Penh, is about 131 km away, to the west of Dar. It is about the same size as El 'Ayoun in Mauritania, which has 23,000.
The closest are Suong (49 km west), Preaek Prasab (63 km north) and Bavet (81 km south). Five other listed cities lie within 100 km, and 16 within 300 km. The farthest listed city in Cambodia is Paoy Paet, about 436 km north-west of Dar.
| City | Distance | People | What wears HVAC transformers first |
|---|---|---|---|
| Suong | 49 km west | 30,000 | moisture on terminals and corrosion |
| Preaek Prasab | 63 km north | 64,000 | terminals loosening and parts running hot |
| Bavet | 81 km south | 44,000 | moisture on terminals and corrosion |
| Svay Rieng | 84 km south | 24,000 | moisture on terminals and corrosion |
| Prey Veng | 90 km west | 33,000 | moisture on terminals and corrosion |
| Phnom Penh | 131 km west | 1.6 million | moisture on terminals and corrosion |
In a smaller city like Dar, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
The sun and the clock in Dar
Dar keeps UTC+7 all year.
Sunlight at 11.8° N (Dar): about 12 h 49 min of daylight in June, about 11 h 26 min in December, and a noon sun that reaches 78° in June and 55° in December. The sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. The climate in Dar is hot and humid tropical, in line with the rest of Cambodia; 23 other listed cities share it.
Where HVAC transformers are used in Dar
Typical work in Dar that needs HVAC transformers:
- Thermostat, contactor and relay supplies
- Fan coil unit and zone valve power
- 24 V control circuits in split and packaged air conditioners
Klima HVAC transformers models
| Model | Primary voltage (V) | Secondary voltage (V) | Rating (VA) |
|---|---|---|---|
| Klima HVAC Transformer 230 V to 24 V, 40 VA | 230 V | 24 V AC | 40 |
| Klima HVAC Transformer 110 V to 24 V, 40 VA | 110/120 V | 24 V AC | 40 |
| Klima HVAC Transformer 230 V to 24 V, 75 VA | 230 V | 24 V AC | 75 |
| Klima HVAC Transformer 400 V to 24 V, 100 VA | 380/400 V | 24 V AC | 100 |
See the full Klima Transformer for HVAC range for specifications, standards and a plain-language guide to choosing the right part.
Selecting HVAC transformers in Dar
- Check the secondary voltage the thermostat and contactors need; most HVAC controls use 24 V AC.
- Confirm the supply first: Cambodia uses 230 V at 50 Hz, so check the voltage and frequency rating of HVAC transformers against the equipment nameplate.
Care and maintenance in Dar
- Tighten terminals and keep ventilation slots clear of dust.
A tropical climate keeps cooling demand steady through the year in Dar, so there is no quiet season. Schedule checks of HVAC transformers around the main rainy-season changes and keep spares on hand. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.
Signs of trouble
- A control circuit that is dead although mains is present
Supply and delivery to Dar
To order HVAC transformers for Dar, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Cambodia are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
HVAC transformers in Dar: common questions
Can I replace a 40 VA transformer with a larger one?
Yes. A higher VA rating is safe because the load only draws what it needs, as long as voltages and frequency match. A lower VA rating can overheat.
What voltage should HVAC transformers be rated for in Dar?
With a 230 V, 50 Hz supply, Cambodia follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every transformer against the equipment it serves.
How are HVAC transformers delivered to Dar?
Shipments for Dar normally clear customs at one of the main entry points of Cambodia and finish the journey by road; send your delivery address with the enquiry.
Which parts of Dar can I order for?
Enquiries are welcome from every part of Dar. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Dar?
Dar keeps UTC+7 all year. At 11.8° N there are about 12 h 49 min of daylight in June and about 11 h 26 min in December.
Which cities near Dar can the same order serve?
The listed cities closest to Dar are Suong (49 km west), Preaek Prasab (63 km north) and Bavet (81 km south). Combine them into one order and give each delivery address.
More Klima products for Dar
- Klima Contactors in Dar
- Klima Delay on Make Timer in Dar
- Klima Thermostats in Dar
- Klima Copper Coils & Tubes in Dar
- Klima Terminal Crimps in Dar
- Klima Pressure Switches (High & Low) in Dar