Klima capacitors for Xiamen
Found in China, Xiamen is a major city with a humid subtropical climate. Summers are hot and humid, with heavy seasonal rain, while winters are cooler and milder.
Capacitors are bought here mainly for offices, shops and malls, factories and workshops as well as homes and apartments. Klima Industries lists 116 models in this range; a selection is shown below, and enquiries from Xiamen are welcome.
- Country
- China
- Population
- 4.6 million
- Climate
- Humid subtropical
- Coordinates
- 24.5° N, 118.1° E
- Time zone
- UTC+8 all year
- From Beijing
- 1,723 km south
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Xiamen · Klima Capacitors overview
What Xiamen demands of capacitors
In Xiamen, cooling demand peaks through a long, humid summer. Damp air can track across dirty or unprotected connections; fit capacitors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; capacitors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.
Where capacitors go from Xiamen
By population Xiamen is 22nd of the 60 cities listed for China, with roughly 1.4% of their combined population, about 19% of the size of Shanghai, the largest. From Beijing, the capital, Xiamen is roughly 1,723 km to the south. It is about the same size as Kolkata in India, which has 4.6 million.
The closest are Shantou (190 km south-west), Fuzhou (215 km north-east) and Huizhou (403 km west). No other listed city lies within 100 km, and two lie within 300 km.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Shantou | 190 km south-west | 3.8 million | terminals loosening and parts running hot |
| Fuzhou | 215 km north-east | 3.7 million | terminals loosening and parts running hot |
| Huizhou | 403 km west | 2.9 million | terminals loosening and parts running hot |
| Shenzhen | 462 km south-west | 17.5 million | moisture on terminals and corrosion |
| Wenzhou | 469 km north-east | 2.7 million | terminals loosening and parts running hot |
| Dongguan | 470 km west | 9.6 million | moisture on terminals and corrosion |
In a major city like Xiamen, installers can usually find common ratings locally, but unusual values and certified parts take longer. Order those early and send the nameplate details.
Daylight and sun angle in Xiamen
Xiamen keeps UTC+8 all year.
Sunlight at 24.5° N (Xiamen): about 13 h 39 min of daylight in June, about 10 h 37 min in December, and a noon sun that reaches 89° in June and 42° in December. The sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. The climate in Xiamen is humid subtropical, in line with the rest of China; 37 other listed cities share it.
Where capacitors are used in Xiamen
Capacitors are most often specified in Xiamen for:
- Fan coil unit and blower motors
- Chiller and air-cooled condenser fans
- Water pumps and booster sets used with HVAC plant
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
How to pick capacitors for work in Xiamen
- Confirm physical fit. Diameter, height and bracket style matter when space inside the outdoor unit is tight.
- Confirm the supply first: China uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
Care and maintenance in Xiamen
- Discharge the capacitor through an insulated resistor before handling it; a charged capacitor can hold a dangerous voltage after power is removed.
In the northern hemisphere the busiest cooling months fall from June to September; April or May is a sensible time to check capacitors in Xiamen. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.
Signs of trouble
- A humming compressor that fails to start, or a fan that has to be spun by hand
Getting capacitors to Xiamen
Shipments for Xiamen normally clear customs at one of the main entry points of China and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for China are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Capacitors in Xiamen: common questions
How do I wire a dual-run capacitor?
The terminals are marked C (common), HERM (hermetic compressor) and FAN. Move each wire to the same marked terminal on the new capacitor, and photograph the old wiring before you disconnect it.
What voltage should capacitors be rated for in Xiamen?
The mains supply in China is 230 V, 50 Hz. Match capacitors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
How are capacitors delivered to Xiamen?
To order capacitors for Xiamen, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Xiamen can I order for?
Enquiries are welcome from every part of Xiamen. Send the delivery address with your enquiry.
Which cities near Xiamen can the same order serve?
The listed cities closest to Xiamen are Shantou (190 km south-west), Fuzhou (215 km north-east) and Huizhou (403 km west). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Xiamen?
Xiamen keeps UTC+8 all year. At 24.5° N there are about 13 h 39 min of daylight in June and about 10 h 37 min in December.
More Klima products for Xiamen
- Klima Contactors in Xiamen
- Klima Terminal Crimps in Xiamen
- Klima Transformer for HVAC in Xiamen
- Klima PVC Tapes in Xiamen
- Klima Drier Core 48-KL in Xiamen
- Klima Pressure Switches (High & Low) in Xiamen