Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Ciro · Klima Capacitors overview
Capacitors and the climate in Ciro
In Ciro, cooling and refrigeration work in every month of the year. Damp air can track across dirty or unprotected connections; fit capacitors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Cities around Ciro that need capacitors
Ciro ranks 45th of the 50 listed cities in Ethiopia and holds about 0.6% of the people living in them, roughly 1.8% of the size of the largest city, Addis Ababa. The capital, Addis Ababa, is about 144 km away, to the north-east of Ciro. For scale, Rajbiraj in Nepal has a similar population (70,000).
The closest are Butajira (35 km north-east), Hosa'ina (52 km south-west) and Ziway (54 km east). 12 other listed cities lie within 100 km, and 27 within 300 km. The farthest listed city in Ethiopia is Warder, about 790 km east of Ciro.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Butajira | 35 km north-east | 90,000 | terminals loosening and parts running hot |
| Hosa'ina | 52 km south-west | 188,000 | moisture on terminals and corrosion |
| Ziway | 54 km east | 91,000 | terminals loosening and parts running hot |
| K'olito | 60 km south | 72,000 | moisture on terminals and corrosion |
| Welk'it'e | 70 km north-west | 78,000 | terminals loosening and parts running hot |
| Arsi Negele | 72 km south-east | 98,000 | terminals loosening and parts running hot |
In a smaller city like Ciro, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
Time zone, sun and daylight in Ciro
Ciro keeps UTC+3 all year.
At 7.8° N, Ciro has about 12 h 35 min of daylight at the June solstice and about 11 h 40 min at the December solstice. The noon sun stands 74° above the horizon in June and 59° in December, and the sun climbs high in summer, so shade and ventilation around outdoor units matter. Ciro has a hot and humid tropical climate, which differs from the highland climate that describes Ethiopia overall; 48 other listed cities share it.
Where capacitors are used in Ciro
In Ciro, these are the jobs that most often call for capacitors:
- Heat pump outdoor units
- Split and window air conditioners
- Fan coil unit and blower motors
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Choosing capacitors for Ciro
- Confirm physical fit. Diameter, height and bracket style matter when space inside the outdoor unit is tight.
- Ask for the datasheet and the documents your project needs; in Ethiopia that usually means Ethiopian Standards Agency (ESA) requirements.
Care and maintenance in Ciro
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
With little seasonal change in temperature, air conditioning in Ciro works almost every day. Spread checks of capacitors through the year instead of waiting for a peak. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Faults to watch for
- Repeated overload trips, high running current or a unit that cuts out on hot afternoons
Ordering capacitors for Ciro
Shipments for Ciro normally clear customs at one of the main entry points of Ethiopia and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Ethiopia are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Capacitors in Ciro: common questions
Can I fit a 440 V capacitor in place of a 370 V one?
Yes. A higher voltage rating is safe and often longer lasting, although the case may be larger. Never fit a lower voltage rating than the original.
What voltage should capacitors be rated for in Ciro?
With a 230 V, 50 Hz supply, Ethiopia follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every capacitor against the equipment it serves.
How are capacitors delivered to Ciro?
To order capacitors for Ciro, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Ciro can I order for?
Enquiries are welcome from every part of Ciro. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Ciro?
Ciro keeps UTC+3 all year. At 7.8° N there are about 12 h 35 min of daylight in June and about 11 h 40 min in December.
Which cities near Ciro can the same order serve?
The listed cities closest to Ciro are Butajira (35 km north-east), Hosa'ina (52 km south-west) and Ziway (54 km east). Combine them into one order and give each delivery address.
More Klima products for Ciro
- Klima Contactors in Ciro
- Klima Terminal Crimps in Ciro
- Klima Transformer for HVAC in Ciro
- Klima Condensate Pump in Ciro
- Klima Thermostat Guards in Ciro
- Klima Flux Powder (100 g & 250 g) in Ciro