Klima Industries

Bochum: Klima Capacitors

Bochum is a mid-sized city in Germany. The climate is temperate. Summers are warm rather than extreme and winters are cool, so heating matters as much as cooling.

The main users of capacitors in Bochum are offices, shops and malls as well as factories and workshops. The Klima range includes 116 models, and the models below show how it spans; send an enquiry from Bochum for a quotation.

Country
Germany
Population
386,000
Climate
Temperate
Coordinates
51.5° N, 7.2° E
Time zone
UTC+1, moving to UTC+2 while daylight saving applies
From Berlin
439 km west
Supply
230 V, 50 Hz

Klima Capacitors models

12 of 116 models are listed here. See all 116 models in Klima Capacitors.

All Klima products for Bochum · Klima Capacitors overview

What Bochum demands of capacitors

In Bochum, cooling demand is seasonal, with short hot spells that stress equipment. Large temperature swings expand and contract terminals every day, which gradually loosens connections, so re-tighten the terminals of capacitors during each seasonal service.

High humidity brings condensation and terminal corrosion, so favour insulated, well-sealed capacitors and keep control boxes closed with their gaskets intact.

Where capacitors go from Bochum

By population Bochum is 16th of the 44 cities listed for Germany, with roughly 1.8% of their combined population, about 11% of the size of Berlin, the largest. The capital, Berlin, is about 439 km away, to the east of Bochum. It is about the same size as Abomey-Calavi in Benin, which has 386,000.

Nearest to Bochum: Gelsenkirchen (9 km west), Essen (14 km west) and Dortmund (18 km east). 13 other listed cities lie within 100 km, and 27 within 300 km.

CityDistancePeopleWhat wears capacitors first
Gelsenkirchen9 km west270,000moisture on terminals and corrosion
Essen14 km west593,000expansion and contraction loosening joints
Dortmund18 km east588,000expansion and contraction loosening joints
Hagen22 km south-east199,000expansion and contraction loosening joints
Wuppertal26 km south361,000expansion and contraction loosening joints
Duisburg32 km west504,000expansion and contraction loosening joints

A mid-sized city like Bochum may not hold every rating in stock, so group your needs into one order and send the nameplate details for each part.

Time zone, sun and daylight in Bochum

Bochum keeps UTC+1, moving to UTC+2 while daylight saving applies.

At 51.5° N, Bochum has about 16 h 38 min of daylight at the June solstice and about 7 h 50 min at the December solstice. The noon sun stands 62° above the horizon in June and 15° in December, and the summer sun is high, so outdoor units in unshaded spots take strong direct heat. The climate in Bochum is temperate, in line with the rest of Germany; 43 other listed cities share it.

Where capacitors are used in Bochum

Typical work in Bochum that needs capacitors:

  • Fan coil unit and blower motors
  • Condensing units for walk-in cold rooms
  • Heat pump outdoor units

Klima capacitors models

ModelCapacitance (µF)Rated voltage (VAC)Type
Klima Run Capacitor 5 µF 440/370 V, Round5440 / 370Single run
Klima Motor Start Capacitor 36-43 µF 250 V36-43250Start
Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case108-130330Start
Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type12500Start/run

See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.

Choosing capacitors for Bochum

  • Match capacitance to the nameplate. Stay within the tolerance printed on the original capacitor, usually ±5 %; a value that is too low or too high shortens motor life.
  • Ask for the datasheet and the documents your project needs; in Germany that usually means CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations.

Keeping capacitors reliable in Bochum

  • Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.

Bochum lies in the northern hemisphere, where cooling demand usually peaks in July and August. Schedule inspections of capacitors for May or June, ahead of that peak. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.

Faults to watch for

  • A swollen, bulging or leaking case

Ordering capacitors for Bochum

To order capacitors for Bochum, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

National rules, standards and voltage for Germany are summarised on the country page.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Capacitors in Bochum: common questions

How do I wire a dual-run capacitor?

The terminals are marked C (common), HERM (hermetic compressor) and FAN. Move each wire to the same marked terminal on the new capacitor, and photograph the old wiring before you disconnect it.

What voltage should capacitors be rated for in Bochum?

Germany supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so capacitors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.

How are capacitors delivered to Bochum?

Shipments for Bochum normally clear customs at one of the main entry points of Germany and finish the journey by road; send your delivery address with the enquiry.

Which parts of Bochum can I order for?

Enquiries are welcome from every part of Bochum. Send the delivery address with your enquiry.

Which cities near Bochum can the same order serve?

The listed cities closest to Bochum are Gelsenkirchen (9 km west), Essen (14 km west) and Dortmund (18 km east). Combine them into one order and give each delivery address.

What local time and daylight should I plan for in Bochum?

Bochum keeps UTC+1, moving to UTC+2 while daylight saving applies. At 51.5° N there are about 16 h 38 min of daylight in June and about 7 h 50 min in December.

More Klima products for Bochum

Capacitors in cities near Bochum