Capacitors supply in Duisburg
Duisburg is a mid-sized city in Germany. The climate is temperate. Summers are warm rather than extreme and winters are cool, so heating matters as much as cooling.
The main users of capacitors in Duisburg are offices, shops and malls as well as factories and workshops. The Klima range includes 116 models, and the models below show how it spans; send an enquiry from Duisburg for a quotation.
- Country
- Germany
- Population
- 504,000
- Climate
- Temperate
- Coordinates
- 51.4° N, 6.8° E
- Time zone
- UTC+1, moving to UTC+2 while daylight saving applies
- From Berlin
- 471 km west
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Duisburg · Klima Capacitors overview
Capacitors and the climate in Duisburg
In Duisburg, cooling demand is seasonal, with short hot spells that stress equipment. Daily heating and cooling cycles work screwed and crimped connections loose over time; check the torque on the terminals of capacitors at least once a year.
Damp air can track across dirty or unprotected connections; fit capacitors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Where capacitors go from Duisburg
By population Duisburg is 15th of the 44 cities listed for Germany, with roughly 2.3% of their combined population, roughly 15% of the size of the largest city, Berlin. From Berlin, the capital, Duisburg is roughly 471 km to the west. It is about the same size as Arak in Iran, which has 504,000.
The closest are Essen (17 km east), Krefeld (18 km south-west) and Dusseldorf (23 km south). 14 other listed cities lie within 100 km, and 25 within 300 km. The farthest listed city in Germany is Munich, about 503 km south-east of Duisburg.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Essen | 17 km east | 593,000 | expansion and contraction loosening joints |
| Krefeld | 18 km south-west | 238,000 | moisture on terminals and corrosion |
| Dusseldorf | 23 km south | 619,000 | expansion and contraction loosening joints |
| Gelsenkirchen | 24 km east | 270,000 | moisture on terminals and corrosion |
| Bochum | 32 km east | 386,000 | moisture on terminals and corrosion |
| Wuppertal | 33 km south-east | 361,000 | moisture on terminals and corrosion |
A mid-sized city like Duisburg may not hold every rating in stock, so group your needs into one order and send the nameplate details for each part.
Daylight and sun angle in Duisburg
Duisburg keeps UTC+1, moving to UTC+2 while daylight saving applies.
Duisburg lies at 51.4° N, 6.8° E. Daylight lasts about 16 h 38 min at the June solstice and about 7 h 50 min in December, with a noon sun 62° and 15° high; the summer sun is high, so outdoor units in unshaded spots take strong direct heat. The climate in Duisburg is temperate, in line with the rest of Germany; 43 other listed cities share it.
Typical uses of capacitors in Duisburg
Capacitors are most often specified in Duisburg for:
- Fan coil unit and blower motors
- Split and window air conditioners
- Packaged rooftop units and ducted systems
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting capacitors in Duisburg
- Confirm physical fit. Diameter, height and bracket style matter when space inside the outdoor unit is tight.
- For temperate conditions in Duisburg, allow for wide seasonal temperature swings.
Keeping capacitors reliable in Duisburg
- Discharge the capacitor through an insulated resistor before handling it; a charged capacitor can hold a dangerous voltage after power is removed.
Because Duisburg is in the northern hemisphere, the heaviest cooling load normally falls in July and August. Service capacitors in May or June, while the load is still light. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.
Signs of trouble
- A swollen, bulging or leaking case
Ordering capacitors for Duisburg
To order capacitors for Duisburg, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Germany are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Capacitors in Duisburg: common questions
Can I replace a capacitor with a higher µF value?
Only within the manufacturer's tolerance, typically ±5 %. A much larger value overheats the winding and a much smaller one reduces starting torque, so always match the original µF rating.
What voltage should capacitors be rated for in Duisburg?
With a 230 V, 50 Hz supply, Germany follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every capacitor against the equipment it serves.
How are capacitors delivered to Duisburg?
Shipments for Duisburg normally clear customs at one of the main entry points of Germany and finish the journey by road; send your delivery address with the enquiry.
Which parts of Duisburg can I order for?
Enquiries are welcome from every part of Duisburg. Send the delivery address with your enquiry.
Which cities near Duisburg can the same order serve?
The listed cities closest to Duisburg are Essen (17 km east), Krefeld (18 km south-west) and Dusseldorf (23 km south). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Duisburg?
Duisburg keeps UTC+1, moving to UTC+2 while daylight saving applies. At 51.4° N there are about 16 h 38 min of daylight in June and about 7 h 50 min in December.
More Klima products for Duisburg
- Klima Contactors in Duisburg
- Klima Terminal Crimps in Duisburg
- Klima Transformer for HVAC in Duisburg
- Klima Thermostat Guards in Duisburg
- Klima PVC Tapes in Duisburg
- Klima Pressure Switches (High & Low) in Duisburg