Capacitors supply in Athens
As the capital of Greece, Athens is a mid-sized city with about 664,000 people. Summers are hot and dry, with long spells above 30 °C, and winters are mild and wetter.
Capacitors are bought here mainly for offices, shops and malls as well as homes and apartments. Klima Industries lists 116 models in this range; a selection is shown below, and enquiries from Athens are welcome.
- Country
- Greece
- Population
- 664,000
- Climate
- Mediterranean
- Coordinates
- 38.0° N, 23.7° E
- Time zone
- UTC+2, moving to UTC+3 while daylight saving applies
- Supply
- 230 V, 50 Hz
- Status
- National capital
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Athens · Klima Capacitors overview
What Athens demands of capacitors
In Athens, cooling demand peaks from late spring to early autumn. Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; capacitors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.
Large temperature swings expand and contract terminals every day, which gradually loosens connections, so re-tighten the terminals of capacitors during each seasonal service.
Capacitors in Athens and the cities near it
Athens ranks first of the 21 listed cities in Greece and holds about 29% of the people living in them, about 2.1 times the size of Thessaloniki, the next largest. It is about the same size as Zagreb in Croatia, which has 664,000.
In the directory the nearest cities are Chalkida (54 km north), Lamia (152 km north-west) and Volos (168 km north-west). One other listed city lies within 100 km, and 10 within 300 km. At the other extreme, Rodos is about 434 km east of Athens, the furthest listed city in Greece.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Chalkida | 54 km north | 59,000 | expansion and contraction loosening joints |
| Lamia | 152 km north-west | 52,000 | expansion and contraction loosening joints |
| Volos | 168 km north-west | 86,000 | expansion and contraction loosening joints |
| Kalamata | 177 km south-west | 54,000 | terminals loosening and parts running hot |
| Patra | 177 km west | 168,000 | terminals loosening and parts running hot |
| Agrinio | 214 km west | 47,000 | terminals loosening and parts running hot |
A mid-sized city like Athens may not hold every rating in stock, so group your needs into one order and send the nameplate details for each part.
The areas listed for Athens range across industrial areas such as Votanikos, Aspropyrgos and Elefsina, port and free-zone areas such as Piraeus and central business districts such as Marousi and Syntagma; buyers in each have different needs, and the area pages below describe them.
Daylight and sun angle in Athens
Local time in Athens is UTC+2, moving to UTC+3 while daylight saving applies.
Athens lies at 38.0° N, 23.7° E. Daylight lasts about 14 h 48 min at the June solstice and about 9 h 31 min in December, with a noon sun 75° and 29° high; the sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. Athens has a Mediterranean climate, the same as the country as a whole, and 20 other listed cities share it.
Typical uses of capacitors in Athens
Typical work in Athens that needs capacitors:
- Fan coil unit and blower motors
- Split and window air conditioners
- Heat pump outdoor units
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting capacitors in Athens
- Match capacitance to the nameplate. Stay within the tolerance printed on the original capacitor, usually ±5 %; a value that is too low or too high shortens motor life.
- Confirm the supply first: Greece uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
Care and maintenance in Athens
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
Because Athens is in the northern hemisphere, the heaviest cooling load normally falls from June to September. Service capacitors in April or May, while the load is still light. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.
Signs of trouble
- A swollen, bulging or leaking case
Ordering capacitors for Athens
Shipments for Athens normally clear customs at one of the main entry points of Greece and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Greece are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Questions about capacitors in Athens
Are run capacitors polarised?
No. AC motor run capacitors are not polarised, so wiring polarity does not matter except where the terminals of a dual capacitor are labelled for different loads.
What voltage should capacitors be rated for in Athens?
The mains supply in Greece is 230 V, 50 Hz. Match capacitors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
How are capacitors delivered to Athens?
To order capacitors for Athens, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Athens can I order for?
Enquiries are welcome from every part of Athens, including Acharnes, Aspropyrgos, Elefsina, Glyfada, Kallithea, Kifisia, Marousi and Piraeus. Send the delivery address with your enquiry.
Which cities near Athens can the same order serve?
The listed cities closest to Athens are Chalkida (54 km north), Lamia (152 km north-west) and Volos (168 km north-west). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Athens?
Athens keeps UTC+2, moving to UTC+3 while daylight saving applies. At 38.0° N there are about 14 h 48 min of daylight in June and about 9 h 31 min in December.
More Klima products for Athens
- Klima Contactors in Athens
- Klima Terminal Crimps in Athens
- Klima Transformer for HVAC in Athens
- Klima Pressure Switches (High & Low) in Athens
- Klima Cables (3 & 4 Core) in Athens
- Klima Filter Driers in Athens