Klima Capacitors in Bang Na, Bangkok
Bang Na is an industrial area in Bangkok, Thailand. Typical customers are maintenance contractors, plant operators and workshops, and what they want is exact-match replacements, fast turnaround and trade quantities.
Capacitors are bought here mainly for factories and workshops as well as cold stores and food distribution. The Klima range includes 116 models, and the models below show how it spans; send an enquiry from Bang Na, Bangkok for a quotation.
- Area type
- Industrial area
- City
- Bangkok
- Country
- Thailand
- Climate
- Hot and humid tropical
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Bang Na, Bangkok · Klima Capacitors overview
Conditions in Bang Na, Bangkok that affect capacitors
In Bang Na, Bangkok, cooling and refrigeration work in every month of the year. Damp air can track across dirty or unprotected connections; fit capacitors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Bang Na, Bangkok at a glance
Alongside Khlong Toei Port, Sukhumvit, Lat Krabang and Phra Khanong, Bang Na is one of 11 named areas in Bangkok, a city of about 5.1 million people, the national capital.
Industrial users in Bang Na switch heavy motor loads many times a day, so contactors and capacitors need generous duty ratings and tight terminals, not just a matching nameplate.
Where Bang Na fits in Bangkok
Bang Na is one of 11 areas listed for Bangkok, and one of 2 classed as industrial areas. More industrial areas in Bangkok, each with its own page, include Lat Krabang. Elsewhere in Bangkok the directory also names Silom, Pratunam, Chatuchak, Yaowarat and Khlong Toei Port.
Typical uses of capacitors in Bang Na, Bangkok
Typical work in Bang Na, Bangkok that needs capacitors:
- Condensing units for walk-in cold rooms
- Commercial display fridges and freezers
- Packaged rooftop units and ducted systems
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting capacitors in Bang Na, Bangkok
- Check dual sections carefully. The HERM, FAN and C terminals must go to the same places as on the old part.
- Ask for the datasheet and the documents your project needs; in Thailand that usually means TISI standards for regulated products.
Keeping capacitors reliable in Bang Na, Bangkok
- Measure capacitance during each seasonal service; a drop of more than about 10 % from the rated value is a reason to replace it.
With little seasonal change in temperature, air conditioning in Bang Na, Bangkok works almost every day. Spread checks of capacitors through the year instead of waiting for a peak. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Signs of trouble
- A swollen, bulging or leaking case
Ordering capacitors for Bang Na, Bangkok
Send the delivery address in Bang Na, or a collection point in Bangkok, together with the model and quantity you need.
National rules, standards and voltage for Thailand are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Capacitors in Bang Na, Bangkok: common questions
What is the difference between a run capacitor and a start capacitor?
A run capacitor stays in circuit whenever the motor runs and improves torque and efficiency. A start capacitor is in circuit for only a second or two to give a high-torque kick, then a relay removes it. Most air conditioner compressors use run capacitors; start capacitors appear on hard-starting motors such as some refrigeration compressors.
What voltage should capacitors be rated for in Bang Na, Bangkok?
Thailand supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so capacitors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.
How are capacitors delivered to Bang Na, Bangkok?
Deliveries for Bang Na are arranged to Bangkok; give a street address or a collection point in your enquiry.
What do buyers in Bang Na usually need?
Bang Na is an industrial area, so the buyers are mostly maintenance contractors, plant operators and workshops. They want exact-match replacements, fast turnaround and trade quantities.
More Klima products for Bang Na, Bangkok
- Klima Contactors in Bang Na, Bangkok
- Klima Terminal Crimps in Bang Na, Bangkok
- Klima Transformer for HVAC in Bang Na, Bangkok
- Klima Thermometers for HVAC in Bang Na, Bangkok
- Klima Filter Driers in Bang Na, Bangkok
- Klima Flux Powder (100 g & 250 g) in Bang Na, Bangkok