Klima Capacitors supplied to Bassar
With about 62,000 people, Bassar is a smaller city in Togo. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
The main users of capacitors in Bassar are offices, shops and malls, factories and workshops as well as homes and apartments. The Klima range includes 116 models, and the models below show how it spans; send an enquiry from Bassar for a quotation.
- Country
- Togo
- Population
- 62,000
- Climate
- Hot and humid tropical
- Coordinates
- 9.3° N, 0.8° E
- Time zone
- UTC+0 all year
- From Lome
- 350 km north
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Bassar · Klima Capacitors overview
Conditions in Bassar that affect capacitors
In Bassar, cooling and refrigeration work in every month of the year. Damp air can track across dirty or unprotected connections; fit capacitors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; capacitors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.
Cities around Bassar that need capacitors
By population Bassar is 6th of the 19 cities listed for Togo, with roughly 2% of their combined population, roughly 2.8% of the size of the largest city, Lome. Bassar lies about 350 km north of Lome, the capital. For scale, Bamyan in Afghanistan has a similar population (62,000).
In the directory the nearest cities are Sokode (49 km south-east), Bafilo (54 km east) and Kara (56 km north-east). Six other listed cities lie within 100 km, and 14 within 300 km. The farthest listed city in Togo is Lome, about 350 km south of Bassar.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Sokode | 49 km south-east | 118,000 | moisture on terminals and corrosion |
| Bafilo | 54 km east | 23,000 | moisture on terminals and corrosion |
| Kara | 56 km north-east | 104,000 | moisture on terminals and corrosion |
| Niamtougou | 68 km north-east | 23,000 | moisture on terminals and corrosion |
| Tchamba | 74 km east | 26,000 | terminals loosening and parts running hot |
| Sotouboua | 80 km south | 24,000 | moisture on terminals and corrosion |
In a smaller city like Bassar, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
Time zone, sun and daylight in Bassar
The clock in Bassar follows UTC+0 all year.
Sunlight at 9.3° N (Bassar): about 12 h 40 min of daylight in June, about 11 h 35 min in December, and a noon sun that reaches 76° in June and 57° in December. The sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. Bassar has a hot and humid tropical climate, the same as the country as a whole, and 18 other listed cities share it.
Typical uses of capacitors in Bassar
Typical work in Bassar that needs capacitors:
- Ventilation and exhaust fan motors
- Heat pump outdoor units
- Water pumps and booster sets used with HVAC plant
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
Choosing capacitors for Bassar
- Match capacitance to the nameplate. Stay within the tolerance printed on the original capacitor, usually ±5 %; a value that is too low or too high shortens motor life.
- Confirm the supply first: Togo uses 230 V at 50 Hz, so check the voltage and frequency rating of capacitors against the equipment nameplate.
Keeping capacitors reliable in Bassar
- Discharge the capacitor through an insulated resistor before handling it; a charged capacitor can hold a dangerous voltage after power is removed.
With little seasonal change in temperature, air conditioning in Bassar works almost every day. Spread checks of capacitors through the year instead of waiting for a peak. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Faults to watch for
- Repeated overload trips, high running current or a unit that cuts out on hot afternoons
Supply and delivery to Bassar
To order capacitors for Bassar, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Togo are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Questions about capacitors in Bassar
What is the difference between a run capacitor and a start capacitor?
A run capacitor stays in circuit whenever the motor runs and improves torque and efficiency. A start capacitor is in circuit for only a second or two to give a high-torque kick, then a relay removes it. Most air conditioner compressors use run capacitors; start capacitors appear on hard-starting motors such as some refrigeration compressors.
What voltage should capacitors be rated for in Bassar?
The mains supply in Togo is 230 V, 50 Hz. Match capacitors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.
How are capacitors delivered to Bassar?
Shipments for Bassar normally clear customs at one of the main entry points of Togo and finish the journey by road; send your delivery address with the enquiry.
Which parts of Bassar can I order for?
Enquiries are welcome from every part of Bassar. Send the delivery address with your enquiry.
Which cities near Bassar can the same order serve?
The listed cities closest to Bassar are Sokode (49 km south-east), Bafilo (54 km east) and Kara (56 km north-east). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Bassar?
Bassar keeps UTC+0 all year. At 9.3° N there are about 12 h 40 min of daylight in June and about 11 h 35 min in December.
More Klima products for Bassar
- Klima Contactors in Bassar
- Klima Terminal Crimps in Bassar
- Klima Transformer for HVAC in Bassar
- Klima Cables (3 & 4 Core) in Bassar
- Klima Flux Powder (100 g & 250 g) in Bassar
- Klima Thermometers for HVAC in Bassar