Klima Capacitors in Kara
Kara is a smaller city in Togo. The climate is hot and humid tropical. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
The main users of capacitors in Kara are offices, shops and malls as well as factories and workshops. The Klima range includes 116 models, and the models below show how it spans; send an enquiry from Kara for a quotation.
- Country
- Togo
- Population
- 104,000
- Climate
- Hot and humid tropical
- Coordinates
- 9.6° N, 1.2° E
- Time zone
- UTC+0 all year
- From Lome
- 381 km north
- Supply
- 230 V, 50 Hz
Klima Capacitors models
- Klima Run Capacitor 5 µF 440/370 V, Round Capacitance: 5 µF, Rated voltage: 440 / 370 VAC, Type: Single run
- Klima Run Capacitor 20 µF 440 V, Oval Aluminium Case Capacitance: 20 µF, Rated voltage: 440 VAC, Type: Single run
- Klima Dual Run Capacitor 40+3 µF 440/370 V, Round Capacitance: 40 + 3 µF, Rated voltage: 440 / 370 VAC, Type: Dual run
- Klima CBB65 Dual Run Capacitor 45+5 µF Capacitance: 45 + 5 µF, Type: Dual run
- Klima Motor Start Capacitor 50-63 µF 250 V Capacitance: 50-63 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 108-130 µF 250 V Capacitance: 108-130 µF, Rated voltage: 250 VAC, Type: Start
- Klima Motor Start Capacitor 216-260 µF 250 V Capacitance: 216-260 µF, Rated voltage: 250 VAC, Type: Start
- Klima Start Capacitor 400-480 µF 110/125 V, Round Phenolic Case Capacitance: 400-480 µF, Rated voltage: 110 / 125 VAC, Type: Start
- Klima CBB61 Start/Run Capacitor 1 µF 500 V AC Capacitance: 1 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 5 µF 500 V AC Capacitance: 5 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 2.2 µF 500 V AC, Terminal Type Capacitance: 2.2 µF, Rated voltage: 500 VAC, Type: Start/run
- Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type Capacitance: 12 µF, Rated voltage: 500 VAC, Type: Start/run
12 of 116 models are listed here. See all 116 models in Klima Capacitors.
All Klima products for Kara · Klima Capacitors overview
Capacitors and the climate in Kara
In Kara, cooling and refrigeration work in every month of the year. Damp air can track across dirty or unprotected connections; fit capacitors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Heat is the main enemy of electrical parts here: capacitors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Where capacitors go from Kara
By population Kara is 3rd of the 19 cities listed for Togo, with roughly 3.4% of their combined population, about 4.8% of the size of Lome, the largest. From Lome, the capital, Kara is roughly 381 km to the north. It is about the same size as Bouafle in Ivory Coast, which has 104,000.
The closest are Bafilo (24 km south), Niamtougou (26 km north) and Bassar (56 km south-west). Five other listed cities lie within 100 km, and 13 within 300 km. At the other extreme, Lome is about 381 km south of Kara, the furthest listed city in Togo.
| City | Distance | People | What wears capacitors first |
|---|---|---|---|
| Bafilo | 24 km south | 23,000 | moisture on terminals and corrosion |
| Niamtougou | 26 km north | 23,000 | terminals loosening and parts running hot |
| Bassar | 56 km south-west | 62,000 | terminals loosening and parts running hot |
| Sokode | 63 km south | 118,000 | terminals loosening and parts running hot |
| Tchamba | 63 km south-east | 26,000 | moisture on terminals and corrosion |
| Sotouboua | 112 km south | 24,000 | terminals loosening and parts running hot |
In a smaller city like Kara, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
Daylight and sun angle in Kara
The clock in Kara follows UTC+0 all year.
Kara lies at 9.6° N, 1.2° E. Daylight lasts about 12 h 41 min at the June solstice and about 11 h 34 min in December, with a noon sun 76° and 57° high; at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. The climate in Kara is hot and humid tropical, in line with the rest of Togo; 18 other listed cities share it.
Typical uses of capacitors in Kara
Capacitors are most often specified in Kara for:
- Heat pump outdoor units
- Ventilation and exhaust fan motors
- Split and window air conditioners
Klima capacitors models
| Model | Capacitance (µF) | Rated voltage (VAC) | Type |
|---|---|---|---|
| Klima Run Capacitor 5 µF 440/370 V, Round | 5 | 440 / 370 | Single run |
| Klima Motor Start Capacitor 36-43 µF 250 V | 36-43 | 250 | Start |
| Klima Start Capacitor 108-130 µF 330 V, Round Phenolic Case | 108-130 | 330 | Start |
| Klima CBB61 Start/Run Capacitor 12 µF 500 V AC, Terminal Type | 12 | 500 | Start/run |
See the full Klima Capacitors range for specifications, standards and a plain-language guide to choosing the right part.
How to pick capacitors for work in Kara
- Check dual sections carefully. The HERM, FAN and C terminals must go to the same places as on the old part.
- For hot and humid tropical conditions in Kara, favour sealed, corrosion-resistant construction.
Care and maintenance in Kara
- Keep terminals clean and tight, and fit insulating boots where supplied to prevent tracking in humid air.
With little seasonal change in temperature, air conditioning in Kara works almost every day. Spread checks of capacitors through the year instead of waiting for a peak. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.
Signs of trouble
- A humming compressor that fails to start, or a fan that has to be spun by hand
Getting capacitors to Kara
Shipments for Kara normally clear customs at one of the main entry points of Togo and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Togo are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about capacitors in Kara
What is the difference between a run capacitor and a start capacitor?
A run capacitor stays in circuit whenever the motor runs and improves torque and efficiency. A start capacitor is in circuit for only a second or two to give a high-torque kick, then a relay removes it. Most air conditioner compressors use run capacitors; start capacitors appear on hard-starting motors such as some refrigeration compressors.
What voltage should capacitors be rated for in Kara?
Togo supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so capacitors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.
How are capacitors delivered to Kara?
To order capacitors for Kara, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Kara can I order for?
Enquiries are welcome from every part of Kara. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Kara?
Kara keeps UTC+0 all year. At 9.6° N there are about 12 h 41 min of daylight in June and about 11 h 34 min in December.
Which cities near Kara can the same order serve?
The listed cities closest to Kara are Bafilo (24 km south), Niamtougou (26 km north) and Bassar (56 km south-west). Combine them into one order and give each delivery address.
More Klima products for Kara
- Klima Contactors in Kara
- Klima Terminal Crimps in Kara
- Klima Transformer for HVAC in Kara
- Klima Thermometers for HVAC in Kara
- Klima Delay on Make Timer in Kara
- Klima Temperature Controllers in Kara