Klima Copper Coils & Tubes supplied to Tshikapa
With about 635,000 people, Tshikapa is a mid-sized city in DR Congo. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
The main users of copper coils and tubes in Tshikapa are offices, shops and malls, factories and workshops as well as homes and apartments. The range below has 6 models; send an enquiry with the model code and your delivery address in Tshikapa.
- Country
- DR Congo
- Population
- 635,000
- Climate
- Hot and humid tropical
- Coordinates
- 6.4° S, 20.8° E
- Time zone
- UTC+2 all year
- From Kinshasa
- 650 km east
- Supply
- 230 V, 50 Hz
Klima Copper Coils & Tubes models
- Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall Size: 1/4 in, Outside diameter: 6.35 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall Size: 3/8 in, Outside diameter: 9.52 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall Size: 1/2 in, Outside diameter: 12.7 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall Size: 5/8 in, Outside diameter: 15.88 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 3/4 in (19.05 mm), 1.0 mm Wall Size: 3/4 in, Outside diameter: 19.05 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 7/8 in (22.2 mm), 1.0 mm Wall Size: 7/8 in, Outside diameter: 22.2 mm, Wall thickness: 1.0 mm
All Klima products for Tshikapa · Klima Copper Coils & Tubes overview
Conditions in Tshikapa that affect copper coils and tubes
In Tshikapa, cooling and refrigeration work in every month of the year. Every minute an open circuit spends in humid air adds moisture, which turns into acid in the oil; fit new copper coils and tubes last and keep the system closed until you are ready to evacuate.
Hot ambient air shortens heating time but dries flux paste quickly, so mix only what you need and keep the tub shaded and closed between joints.
Cities around Tshikapa that need copper coils and tubes
Among the 45 listed cities in DR Congo, Tshikapa comes 9th by population, with about 1.9% of the listed urban population, roughly 4% of the size of the largest city, Kinshasa. From Kinshasa, the capital, Tshikapa is roughly 650 km to the east. For scale, Comilla in Bangladesh has a similar population (635,000).
In the directory the nearest cities are Kananga (188 km east), Idiofa (209 km north-west) and Ilebo (233 km north). No other listed city lies within 100 km, and five lie within 300 km. The farthest listed city in DR Congo is Bakwa, about 1,382 km north-east of Tshikapa.
| City | Distance | People | What wears copper coils and tubes first |
|---|---|---|---|
| Kananga | 188 km east | 1.2 million | moisture entering the circuit and corrosion |
| Idiofa | 209 km north-west | 88,000 | high head pressure and hot joints |
| Ilebo | 233 km north | 117,000 | high head pressure and hot joints |
| Kikwit | 267 km north-west | 509,000 | moisture entering the circuit and corrosion |
| Mwene-Ditu | 300 km east | 189,000 | high head pressure and hot joints |
| Mbuji-Mayi | 310 km east | 2.1 million | high head pressure and hot joints |
In a mid-sized city like Tshikapa, specialist refrigeration items can take longer to source locally. Combine tube, driers and consumables into a single order.
The sun and the clock in Tshikapa
The clock in Tshikapa follows UTC+2 all year. That puts it 1 hour ahead of Kinshasa, so allow for the difference when you book a delivery slot.
Tshikapa lies at 6.4° S, 20.8° E. Daylight lasts about 11 h 45 min at the June solstice and about 12 h 30 min in December, with a noon sun 60° and 73° high; the summer sun is high, so outdoor units in unshaded spots take strong direct heat. Tshikapa has a hot and humid tropical climate, the same as the country as a whole, and 43 other listed cities share it.
Where copper coils and tubes are used in Tshikapa
In Tshikapa, these are the jobs that most often call for copper coils and tubes:
- Replacement coils and repair sections
- VRF and multi-split branch piping
- Split-system liquid and suction lines
Klima copper coils and tubes models
| Model | Size (in) | Outside diameter (mm) | Wall thickness (mm) |
|---|---|---|---|
| Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall | 1/4 in | 6.35 | 0.8 |
| Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall | 3/8 in | 9.52 | 0.8 |
| Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall | 1/2 in | 12.7 | 0.8 |
| Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall | 5/8 in | 15.88 | 1.0 |
See the full Klima Copper Coils & Tubes range for specifications, standards and a plain-language guide to choosing the right part.
How to pick copper coils and tubes for work in Tshikapa
- Pair liquid and suction lines with insulation of the correct bore and thickness.
- For hot and humid tropical conditions in Tshikapa, favour sealed, corrosion-resistant construction.
Keeping copper coils and tubes reliable in Tshikapa
- Braze with a nitrogen purge to prevent internal oxide scale, then pressure test and evacuate before charging.
A tropical climate keeps cooling demand steady through the year in Tshikapa, so there is no quiet season. Schedule checks of copper coils and tubes around the main rainy-season changes and keep spares on hand. Pipe work and brazing are easiest when the system can be shut down for a day or two, so do them before the peak.
Faults to watch for
- A system that loses charge slowly
Supply and delivery to Tshikapa
Shipments for Tshikapa normally clear customs at one of the main entry points of DR Congo and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for DR Congo are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Copper coils and tubes in Tshikapa: common questions
Which copper tube is used for air conditioners?
Seamless refrigeration-grade (ACR) copper tube, cleaned and capped, is used for refrigerant lines. Common air conditioner sizes include 1/4, 3/8, 1/2, 5/8 and 3/4 inch outside diameters.
How does the climate in Tshikapa affect copper coils and tubes?
Humid air makes moisture ingress the biggest installation risk, so keep copper coils and tubes sealed until use, braze under nitrogen and evacuate to a deep vacuum before charging.
How are copper coils and tubes delivered to Tshikapa?
To order copper coils and tubes for Tshikapa, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Tshikapa can I order for?
Enquiries are welcome from every part of Tshikapa. Send the delivery address with your enquiry.
Which cities near Tshikapa can the same order serve?
The listed cities closest to Tshikapa are Kananga (188 km east), Idiofa (209 km north-west) and Ilebo (233 km north). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Tshikapa?
Tshikapa keeps UTC+2 all year. At 6.4° S there are about 11 h 45 min of daylight in June and about 12 h 30 min in December.
More Klima products for Tshikapa
- Klima Filter Driers in Tshikapa
- Klima Flux Powder (100 g & 250 g) in Tshikapa
- Klima Map Gas (Brazing & Welding) in Tshikapa
- Klima Thermometers for HVAC in Tshikapa
- Klima Capacitors in Tshikapa
- Klima Temperature Controllers in Tshikapa