Klima copper coils and tubes for Port Said
Port Said is a mid-sized city in Egypt. The climate is hot and arid. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.
Copper coils and tubes are bought here mainly for offices, shops and malls, factories and workshops as well as homes and apartments. Klima Industries lists 6 models in this range with full specifications below, and enquiries from Port Said are welcome.
- Country
- Egypt
- Population
- 781,000
- Climate
- Hot and arid
- Coordinates
- 31.3° N, 32.3° E
- Time zone
- UTC+2, moving to UTC+3 while daylight saving applies
- From Cairo
- 167 km north-east
- Supply
- 230 V, 50 Hz
Klima Copper Coils & Tubes models
- Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall Size: 1/4 in, Outside diameter: 6.35 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall Size: 3/8 in, Outside diameter: 9.52 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall Size: 1/2 in, Outside diameter: 12.7 mm, Wall thickness: 0.8 mm
- Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall Size: 5/8 in, Outside diameter: 15.88 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 3/4 in (19.05 mm), 1.0 mm Wall Size: 3/4 in, Outside diameter: 19.05 mm, Wall thickness: 1.0 mm
- Klima Soft Copper Coil 7/8 in (22.2 mm), 1.0 mm Wall Size: 7/8 in, Outside diameter: 22.2 mm, Wall thickness: 1.0 mm
All Klima products for Port Said · Klima Copper Coils & Tubes overview
What Port Said demands of copper coils and tubes
In Port Said, air conditioning and refrigeration run for most of the year. In very hot weather discharge pressure climbs towards the safety limits; check that copper coils and tubes are rated for the refrigerant in use, and keep condensers clean and fans healthy.
Wind and dust blow the flame away from the joint; use a wind shield, clean the joint thoroughly and keep dust out of flux and gas fittings.
Copper coils and tubes in Port Said and the cities near it
Among the 48 listed cities in Egypt, Port Said comes 4th by population, with about 2.4% of the listed urban population, roughly 8.1% of the size of the largest city, Cairo. The capital, Cairo, is about 167 km away, to the south-west of Port Said. It is about the same size as Seattle in the United States, which has 781,000.
The closest are Al Matariyah (27 km west), Al Manzalah (37 km west) and Damietta (49 km west). Seven other listed cities lie within 100 km, and 32 within 300 km. The farthest listed city in Egypt is Aswan, about 800 km south of Port Said.
| City | Distance | People | What wears copper coils and tubes first |
|---|---|---|---|
| Al Matariyah | 27 km west | 162,000 | dirty condensers raising pressure |
| Al Manzalah | 37 km west | 127,000 | dirty condensers raising pressure |
| Damietta | 49 km west | 306,000 | high head pressure and hot joints |
| Ismailia | 74 km south | 429,000 | dirty condensers raising pressure |
| Abu Kabir | 85 km south-west | 154,000 | high head pressure and hot joints |
| Bilqas | 90 km west | 137,000 | high head pressure and hot joints |
In a mid-sized city like Port Said, specialist refrigeration items can take longer to source locally. Combine tube, driers and consumables into a single order.
Time zone, sun and daylight in Port Said
Port Said keeps UTC+2, moving to UTC+3 while daylight saving applies.
At 31.3° N, Port Said has about 14 h 11 min of daylight at the June solstice and about 10 h 07 min at the December solstice. The noon sun stands 82° above the horizon in June and 35° in December, and at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. The climate in Port Said is hot and arid, in line with the rest of Egypt; 47 other listed cities share it.
Typical uses of copper coils and tubes in Port Said
In Port Said, these are the jobs that most often call for copper coils and tubes:
- VRF and multi-split branch piping
- Chiller and package unit refrigerant circuits
- Marine and offshore refrigeration
Klima copper coils and tubes models
| Model | Size (in) | Outside diameter (mm) | Wall thickness (mm) |
|---|---|---|---|
| Klima Soft Copper Coil 1/4 in (6.35 mm), 0.8 mm Wall | 1/4 in | 6.35 | 0.8 |
| Klima Soft Copper Coil 3/8 in (9.52 mm), 0.8 mm Wall | 3/8 in | 9.52 | 0.8 |
| Klima Soft Copper Coil 1/2 in (12.7 mm), 0.8 mm Wall | 1/2 in | 12.7 | 0.8 |
| Klima Soft Copper Coil 5/8 in (15.88 mm), 1.0 mm Wall | 5/8 in | 15.88 | 1.0 |
See the full Klima Copper Coils & Tubes range for specifications, standards and a plain-language guide to choosing the right part.
How to pick copper coils and tubes for work in Port Said
- Match outside diameter to the service connections on the indoor and outdoor units, and do not mix imperial and metric sizes without adaptors.
- Ask for the datasheet and the documents your project needs; in Egypt that usually means EOS (Egyptian Organization for Standardization) conformity.
Care and maintenance in Port Said
- Braze with a nitrogen purge to prevent internal oxide scale, then pressure test and evacuate before charging.
In the northern hemisphere the busiest cooling months fall from May to September; March or April is a sensible time to check copper coils and tubes in Port Said. Refrigerant-circuit repairs need a clear working window; book them before the busy period, not during it.
Faults to watch for
- Restricted flow caused by kinks or oxide flakes
Ordering copper coils and tubes for Port Said
To order copper coils and tubes for Port Said, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Egypt are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about copper coils and tubes in Port Said
Can I reuse old copper pipe?
Old pipe can be reused only if it is the right size and wall thickness, clean inside and pressure tested. Contaminated or oil-stained pipe is safer replaced.
How does the climate in Port Said affect copper coils and tubes?
High ambient temperatures push condensing pressure up, so copper coils and tubes must suit the higher working pressure and the system needs a clean condenser to stay inside its limits.
How are copper coils and tubes delivered to Port Said?
Shipments for Port Said normally clear customs at one of the main entry points of Egypt and finish the journey by road; send your delivery address with the enquiry.
Which parts of Port Said can I order for?
Enquiries are welcome from every part of Port Said. Send the delivery address with your enquiry.
Which cities near Port Said can the same order serve?
The listed cities closest to Port Said are Al Matariyah (27 km west), Al Manzalah (37 km west) and Damietta (49 km west). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Port Said?
Port Said keeps UTC+2, moving to UTC+3 while daylight saving applies. At 31.3° N there are about 14 h 11 min of daylight in June and about 10 h 07 min in December.
More Klima products for Port Said
- Klima Filter Driers in Port Said
- Klima Flux Powder (100 g & 250 g) in Port Said
- Klima Map Gas (Brazing & Welding) in Port Said
- Klima Drier Core 48-KL in Port Said
- Klima Cables (3 & 4 Core) in Port Said
- Klima Condensate Pump in Port Said