Buying cables in Port Said
Found in Egypt, Port Said is a mid-sized city with a hot and arid climate. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.
Demand for cables comes mostly from offices, shops and malls, factories and workshops as well as homes and apartments. The Klima range includes 6 models, each with a specification table; send an enquiry from Port Said for a quotation.
- Country
- Egypt
- Population
- 781,000
- Climate
- Hot and arid
- Coordinates
- 31.3° N, 32.3° E
- Time zone
- UTC+2, moving to UTC+3 while daylight saving applies
- From Cairo
- 167 km north-east
- Supply
- 230 V, 50 Hz
Klima Cables (3 & 4 Core) models
- Klima 3-Core Flexible Cable 1.5 mm² Cores: 3, Conductor size: 1.5 mm², Insulation: PVC
- Klima 3-Core Flexible Cable 2.5 mm² Cores: 3, Conductor size: 2.5 mm², Insulation: PVC
- Klima 3-Core Flexible Cable 4 mm² Cores: 3, Conductor size: 4 mm², Insulation: PVC
- Klima 4-Core Flexible Cable 1.5 mm² Cores: 4, Conductor size: 1.5 mm², Insulation: PVC
- Klima 4-Core Flexible Cable 2.5 mm² Cores: 4, Conductor size: 2.5 mm², Insulation: PVC
- Klima 4-Core Flexible Cable 4 mm² Cores: 4, Conductor size: 4 mm², Insulation: PVC
All Klima products for Port Said · Klima Cables (3 & 4 Core) overview
Cables and the climate in Port Said
In Port Said, air conditioning and refrigeration run for most of the year. Heat is the main enemy of electrical parts here: cables run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Fine dust settles on cables and the surrounding wiring, traps heat and can bridge connections, so wipe it away at each service and keep covers and gland plates sealed.
Cables in Port Said and the cities near it
By population Port Said is 4th of the 48 cities listed for Egypt, with roughly 2.4% of their combined population, roughly 8.1% of the size of the largest city, Cairo. From Cairo, the capital, Port Said is roughly 167 km to the north-east. For scale, Seattle in the United States has a similar population (781,000).
In the directory the nearest cities are Al Matariyah (27 km west), Al Manzalah (37 km west) and Damietta (49 km west). Seven other listed cities lie within 100 km, and 32 within 300 km.
| City | Distance | People | What wears cables first |
|---|---|---|---|
| Al Matariyah | 27 km west | 162,000 | dust on contacts and blocked cooling |
| Al Manzalah | 37 km west | 127,000 | dust on contacts and blocked cooling |
| Damietta | 49 km west | 306,000 | dust on contacts and blocked cooling |
| Ismailia | 74 km south | 429,000 | dust on contacts and blocked cooling |
| Abu Kabir | 85 km south-west | 154,000 | terminals loosening and parts running hot |
| Bilqas | 90 km west | 137,000 | terminals loosening and parts running hot |
A mid-sized city like Port Said may not hold every rating in stock, so group your needs into one order and send the nameplate details for each part.
Daylight and sun angle in Port Said
Port Said keeps UTC+2, moving to UTC+3 while daylight saving applies.
Port Said lies at 31.3° N, 32.3° E. Daylight lasts about 14 h 11 min at the June solstice and about 10 h 07 min in December, with a noon sun 82° and 35° high; the sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. Port Said has a hot and arid climate, the same as the country as a whole, and 47 other listed cities share it.
Where cables are used in Port Said
In Port Said, these are the jobs that most often call for cables:
- Fan coil unit and VRF branch wiring
- Pump, fan and compressor motor connections
- Building refurbishment and retrofit work
Klima cables models
| Model | Cores | Conductor size (mm²) | Insulation |
|---|---|---|---|
| Klima 3-Core Flexible Cable 1.5 mm² | 3 | 1.5 | PVC |
| Klima 3-Core Flexible Cable 2.5 mm² | 3 | 2.5 | PVC |
| Klima 3-Core Flexible Cable 4 mm² | 3 | 4 | PVC |
| Klima 4-Core Flexible Cable 1.5 mm² | 4 | 1.5 | PVC |
See the full Klima Cables (3 & 4 Core) range for specifications, standards and a plain-language guide to choosing the right part.
Selecting cables in Port Said
- Size the conductor from the unit's maximum running current and the cable length, and check that voltage drop stays within the limit in your local wiring rules.
- Ask for the datasheet and the documents your project needs; in Egypt that usually means EOS (Egyptian Organization for Standardization) conformity.
Care and maintenance in Port Said
- Support outdoor runs with clips or conduit so the sheath does not chafe or sag.
Port Said lies in the northern hemisphere, where cooling demand usually peaks from May to September. Schedule inspections of cables for March or April, ahead of that peak. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.
Faults to watch for
- Discoloured or brittle sheathing near hot refrigerant lines
Ordering cables for Port Said
Shipments for Port Said normally clear customs at one of the main entry points of Egypt and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Egypt are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Cables in Port Said: common questions
Can I use PVC cable outdoors?
Yes where it is protected from direct sunlight and mechanical damage, for example inside conduit or trunking. Exposed runs benefit from UV-resistant cable or extra protection.
What voltage should cables be rated for in Port Said?
Egypt supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so cables rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.
How are cables delivered to Port Said?
To order cables for Port Said, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Port Said can I order for?
Enquiries are welcome from every part of Port Said. Send the delivery address with your enquiry.
Which cities near Port Said can the same order serve?
The listed cities closest to Port Said are Al Matariyah (27 km west), Al Manzalah (37 km west) and Damietta (49 km west). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Port Said?
Port Said keeps UTC+2, moving to UTC+3 while daylight saving applies. At 31.3° N there are about 14 h 11 min of daylight in June and about 10 h 07 min in December.
More Klima products for Port Said
- Klima Contactors in Port Said
- Klima PVC Tapes in Port Said
- Klima Terminal Crimps in Port Said
- Klima Flux Powder (100 g & 250 g) in Port Said
- Klima Copper Coils & Tubes in Port Said
- Klima Condensate Pump in Port Said