Klima Industries

Klima Pressure Switches (High & Low) in Austria

With about 8.8 million people, Austria is a mid-sized market in Europe. Its capital is Vienna. Most of the country has a temperate climate, and conditions vary by region. Summers are warm rather than extreme and winters are cool, so heating matters as much as cooling.

The main users of pressure switches in Austria are offices, shops and malls as well as factories and workshops. Klima Industries lists 4 models in this range with full specifications below, and enquiries from Austria are welcome.

Capital
Vienna
Population
8.8 million
Area
83,858 km²
Time zone
UTC+1, moving to UTC+2 while daylight saving applies
Climate
Temperate
Supply
230 V, 50 Hz
Standards
CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations

Klima Pressure Switches (High & Low) models

All Klima products for Austria · Klima Pressure Switches (High & Low) overview

What Austria demands of pressure switches

In Austria, cooling demand is seasonal, with short hot spells that stress equipment. Seasonal expansion and contraction stress pipework and joints, so support lines properly and inspect joints near pressure switches for oil traces after the first hot and the first cold spells.

Damp air attacks exposed contacts and boards; fit pressure switches in enclosures that keep moisture out, and check the seals at each service.

Austria supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so pressure switches rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.

Pressure switches across the cities of Austria

The capital, Vienna, is also the largest listed city (about 1.7 million people), which keeps most large buyers in one place. The widest gap between listed cities runs from Vienna to Feldkirch, about 518 km, so allow extra road time for the far end of the country. Climate decides how pressure switches age, and it changes from city to city in Austria: the last column shows what to expect.

CityPeopleClimateWhat wears pressure switches first
Vienna1.7 milliontemperatecondensation inside enclosures
Graz303,000temperatecalibration drift between seasons
Linz205,000temperatecondensation inside enclosures
Salzburg157,000temperatecondensation inside enclosures
Innsbruck132,000temperatecalibration drift between seasons
Wiener Neustadt45,000temperatecondensation inside enclosures

Every one of the 20 listed cities has a temperate climate, which keeps the choice of parts consistent from city to city.

Neighbouring supplies to check before ordering pressure switches

Across the border, Switzerland, Germany, Hungary, Slovakia, the Czech Republic and 3 more also run on a nominal 230 V at 50 Hz, so ratings carry over between Austria and its neighbours; the nameplate of the equipment still decides.

Austria in numbers

The directory puts Austria at about 83,858 km², the 116th largest of its 241 countries, almost exactly the size of the United Arab Emirates (82,880 km²). About 8.8 million people live there, an average of 106 people per km², which makes it densely settled, denser than 58% of the other countries in this directory. Most sites sit within reach of a city, so deliveries can usually be planned city by city. Its population is similar to that of Israel (8.9 million).

Where pressure switches are used in Austria

Typical work in Austria that needs pressure switches:

  • Split, VRF and packaged air conditioners
  • Chillers and air-cooled condensers
  • Heat pump outdoor units
  • Fan speed control by head pressure
  • Ice machines and process cooling

Klima pressure switches models

ModelTypePressure range (bar)Cut-out setting (bar)
Klima High Pressure Switch, Manual ResetHigh pressure8 to 32Adjustable
Klima High Pressure Switch, Auto ResetHigh pressure8 to 32Adjustable
Klima Low Pressure Switch, Auto ResetLow pressure-0.7 to 7Adjustable
Klima Dual Pressure Switch, HP/LPDual HP/LPHP 8 to 32, LP -0.7 to 7Adjustable

See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.

Selecting pressure switches in Austria

  • Use an HP switch with manual reset for safety duty and an LP switch with automatic reset for pump-down or control duty.
  • Match the connection (flare size or capillary) to the service port you will use.
  • Confirm the supply first: Austria uses 230 V at 50 Hz, so check the voltage and frequency rating of pressure switches against the equipment nameplate.
  • For temperate conditions in Austria, allow for wide seasonal temperature swings.

Care and maintenance in Austria

  • Replace a switch that fails to trip at the specified pressure, and do not adjust a safety switch beyond its marked range.

In the northern hemisphere the busiest cooling months fall in July and August; May or June is a sensible time to check pressure switches in Austria. Calibrate and test controls under easy conditions so settings are proven before the load rises.

Faults to watch for

  • A switch that cycles at the wrong pressure

Standards and paperwork for pressure switches in Austria

Klima pressure switches are specified against EN 12263 (safety switching devices for limiting pressure in refrigerating systems), IEC 60947-5-1. For import and installation in Austria, buyers also meet CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations. Ask for the datasheet and conformity documents for the Klima model you plan to specify, so that submittals and import paperwork are complete.

Supply and delivery to Austria

Austria has no coastline, so sea freight normally arrives through ports in neighbouring countries such as Switzerland, Germany, Hungary and Slovakia and continues inland by road or rail; allow extra time for transit and border handling.

The local currency is the Euro (EUR), so confirm the quotation currency and delivery terms before you order. The main languages are German, Croatian, Hungarian and Slovenian; this site and its enquiry form are in English.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Questions about pressure switches in Austria

How do I set the cut-out pressure?

Take the value from the equipment manual for the refrigerant in use and verify it with a gauge set. Never set a switch above the pressure rating of the components it protects.

What voltage should pressure switches be rated for in Austria?

The mains supply in Austria is 230 V, 50 Hz. Match pressure switches to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.

Which standards apply to pressure switches in Austria?

Klima pressure switches follow EN 12263 (safety switching devices for limiting pressure in refrigerating systems), IEC 60947-5-1. In Austria the local framework is CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations; request the datasheet and conformity documents with your enquiry.

How are pressure switches delivered to Austria?

As a landlocked market, Austria receives sea freight through a transit port in a neighbouring country (Switzerland, Germany, Hungary and Slovakia); air freight is the faster option for urgent parts.

Which cities in Austria can I order pressure switches for?

Every listed city is covered. The largest are Vienna (1.7 million), Graz (303,000), Linz (205,000), Salzburg (157,000) and Innsbruck (132,000). The country page lists the rest.

Do the neighbours of Austria use the same mains supply?

Yes. All 8 listed neighbours (Switzerland, Germany, Hungary, Slovakia, the Czech Republic and 3 more) run on a nominal 230 V at 50 Hz, the same as Austria, so the electrical rating of a part does not usually change at the border.

What local time and daylight should I plan for in Austria?

Vienna keeps UTC+1, moving to UTC+2 while daylight saving applies. At 48.2° N there are about 16 h 05 min of daylight in June and about 8 h 20 min in December.

More Klima products for Austria

Pressure switches in cities across Austria