Klima pressure switches for Bahrain
With about 1.6 million people, Bahrain is a smaller national market in Asia. Its capital is Manama. Across Bahrain the climate is hot and arid, and conditions are similar from place to place. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.
Demand for pressure switches comes mostly from offices, shops and malls as well as homes and apartments. Klima Industries lists 4 models in this range with full specifications below, and enquiries from Bahrain are welcome.
- Capital
- Manama
- Population
- 1.6 million
- Area
- 665 km²
- Time zone
- UTC+3 all year
- Climate
- Hot and arid
- Supply
- 230 V, 50 Hz
- Main ports
- Khalifa Bin Salman Port
- Standards
- GSO-based standards and Bahrain conformity requirements
Klima Pressure Switches (High & Low) models
- Klima High Pressure Switch, Manual Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima High Pressure Switch, Auto Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima Low Pressure Switch, Auto Reset Type: Low pressure, Pressure range: -0.7 to 7 bar, Cut-out setting: Adjustable bar
- Klima Dual Pressure Switch, HP/LP Type: Dual HP/LP, Pressure range: HP 8 to 32, LP -0.7 to 7 bar, Cut-out setting: Adjustable bar
All Klima products for Bahrain · Klima Pressure Switches (High & Low) overview
What Bahrain demands of pressure switches
In Bahrain, air conditioning and refrigeration run for most of the year. High ambient temperatures push condensing pressure up, so pressure switches must suit the higher working pressure and the system needs a clean condenser to stay inside its limits.
Dust blocks sensor openings and slows response; clean the vents of pressure switches at each service.
With a 230 V, 50 Hz supply, Bahrain follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every pressure switch against the equipment it serves.
Cities that buy pressure switches in Bahrain
The largest listed city is Muharraq, not the capital: Manama is roughly 4 km to its south-west, and orders should name the right one. The three largest listed cities (Muharraq, Manama and Madinat Hamad) hold about 64% of the people living in listed cities, which means a few centres do most of the buying. Climate decides how pressure switches age, and it changes from city to city in Bahrain: the last column shows what to expect.
| City | People | Climate | What wears pressure switches first |
|---|---|---|---|
| Muharraq | 177,000 | hot and arid | sensor drift and setpoints creeping |
| Manama | 147,000 | hot and arid | sensor drift and setpoints creeping |
| Madinat Hamad | 134,000 | hot and arid | sensor drift and setpoints creeping |
| Ar Rifa' | 115,000 | hot and arid | sensor drift and setpoints creeping |
| Sitrah | 73,000 | hot and arid | dust in enclosures and sticky switches |
| Dar Kulayb | 65,000 | hot and arid | sensor drift and setpoints creeping |
All 6 listed cities share a hot and arid climate, so one stocking plan covers the whole country.
Bahrain in numbers
Bahrain covers about 665 km², the 49th smallest of the 241 countries in this directory, a little smaller than Singapore (692 km²). About 1.6 million people live there, an average of 2,360 people per km², which makes it very densely settled, denser than 98% of the other countries in this directory. With sites this close, orders can be combined by city and delivered in a single run.
Jobs in Bahrain that call for pressure switches
In Bahrain, these are the jobs that most often call for pressure switches:
- Split, VRF and packaged air conditioners
- Chillers and air-cooled condensers
- Heat pump outdoor units
- Fan speed control by head pressure
- Condensing units and cold rooms
Klima pressure switches models
| Model | Type | Pressure range (bar) | Cut-out setting (bar) |
|---|---|---|---|
| Klima High Pressure Switch, Manual Reset | High pressure | 8 to 32 | Adjustable |
| Klima High Pressure Switch, Auto Reset | High pressure | 8 to 32 | Adjustable |
| Klima Low Pressure Switch, Auto Reset | Low pressure | -0.7 to 7 | Adjustable |
| Klima Dual Pressure Switch, HP/LP | Dual HP/LP | HP 8 to 32, LP -0.7 to 7 | Adjustable |
See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.
Choosing pressure switches for Bahrain
- Check the electrical rating against the contactor coil or control circuit it will switch.
- Match the connection (flare size or capillary) to the service port you will use.
- Confirm the supply first: Bahrain uses 230 V at 50 Hz, so check the voltage and frequency rating of pressure switches against the equipment nameplate.
- Ask for the datasheet and the documents your project needs; in Bahrain that usually means GSO-based standards and Bahrain conformity requirements.
Care and maintenance in Bahrain
- Check that connections are leak-free and that capillary tubes are not kinked.
Bahrain lies in the northern hemisphere, where cooling demand usually peaks from May to September. Schedule inspections of pressure switches for March or April, ahead of that peak. Calibrate and test controls under easy conditions so settings are proven before the load rises.
Signs of trouble
- A switch that cycles at the wrong pressure
Which standards apply to pressure switches in Bahrain
Two sets of rules apply to pressure switches sold into Bahrain: the product standard, EN 12263 (safety switching devices for limiting pressure in refrigerating systems), IEC 60947-5-1, and the local one, GSO-based standards and Bahrain conformity requirements. Importers and consultants normally ask for datasheets and test documents, so request them with the enquiry.
Getting pressure switches to Bahrain
Cargo for Bahrain usually arrives through Khalifa Bin Salman Port; tell us your preferred port or delivery address with your enquiry.
The local currency is the Dinar (BHD), so confirm the quotation currency and delivery terms before you order. The main languages are Arabic, English, Persian and Urdu; this site and its enquiry form are in English.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Questions about pressure switches in Bahrain
What does a high pressure switch do?
It opens the control circuit if discharge pressure rises above a set limit, which stops the compressor before the pressure can damage it or the pipework.
What voltage should pressure switches be rated for in Bahrain?
Bahrain supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so pressure switches rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.
Which standards apply to pressure switches in Bahrain?
Klima pressure switches follow EN 12263 (safety switching devices for limiting pressure in refrigerating systems), IEC 60947-5-1. In Bahrain the local framework is GSO-based standards and Bahrain conformity requirements; request the datasheet and conformity documents with your enquiry.
How are pressure switches delivered to Bahrain?
Sea freight into Bahrain normally clears through ports such as Khalifa Bin Salman Port, with onward delivery by road; urgent parts can travel by air.
Which cities in Bahrain can I order pressure switches for?
Every listed city is covered. The largest are Muharraq (177,000), Manama (147,000), Madinat Hamad (134,000), Ar Rifa' (115,000) and Sitrah (73,000). The country page lists the rest.
What local time and daylight should I plan for in Bahrain?
Manama keeps UTC+3 all year. At 26.2° N there are about 13 h 47 min of daylight in June and about 10 h 30 min in December.
More Klima products for Bahrain
- Klima Contactors in Bahrain
- Klima Filter Driers in Bahrain
- Klima Thermometers for HVAC in Bahrain
- Klima Thermostats in Bahrain
- Klima Transformer for HVAC in Bahrain
- Klima Map Gas (Brazing & Welding) in Bahrain