Klima Industries

Buying pressure switches in Denmark

With about 5.8 million people, Denmark is a mid-sized market in Europe. Its capital is Copenhagen. Most of the country has a temperate climate, and conditions vary by region. Summers are warm rather than extreme and winters are cool, so heating matters as much as cooling.

Pressure switches are bought here mainly for offices, shops and malls, cold stores and food distribution as well as homes and apartments. The Klima range includes 4 models, each with a specification table; send an enquiry from Denmark for a quotation.

Capital
Copenhagen
Population
5.8 million
Area
43,094 km²
Time zone
UTC+1, moving to UTC+2 while daylight saving applies
Climate
Temperate
Supply
230 V, 50 Hz
Main ports
Aarhus
Standards
CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations

Klima Pressure Switches (High & Low) models

All Klima products for Denmark · Klima Pressure Switches (High & Low) overview

Conditions in Denmark that affect pressure switches

In Denmark, cooling demand is seasonal, with short hot spells that stress equipment. Seasonal expansion and contraction stress pipework and joints, so support lines properly and inspect joints near pressure switches for oil traces after the first hot and the first cold spells.

Damp air attacks exposed contacts and boards; fit pressure switches in enclosures that keep moisture out, and check the seals at each service.

Denmark supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so pressure switches rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.

Pressure switches across the cities of Denmark

The capital, Copenhagen, is also the largest listed city (about 1.2 million people), which keeps most large buyers in one place. About 65% of the people in listed cities live in Copenhagen, Arhus and Odense; buyers are concentrated in a few centres. These are the biggest listed cities in Denmark; the last column names what to watch for in pressure switches there.

CityPeopleClimateWhat wears pressure switches first
Copenhagen1.2 milliontemperatecondensation inside enclosures
Arhus285,000temperatecondensation inside enclosures
Odense181,000temperatecalibration drift between seasons
Aalborg143,000temperatecondensation inside enclosures
Randers63,000temperatecalibration drift between seasons
Vejle60,000temperatecalibration drift between seasons

Size and settlement in Denmark

By land area Denmark is the 107th smallest of the 241 places listed here, at roughly 43,094 km², a little larger than the Netherlands (41,526 km²). About 5.8 million people live there, an average of 135 people per km², which makes it densely settled, denser than 63% of the other countries in this directory. Customers are rarely far from a city, so a delivery plan by city is normally enough. For scale, Turkmenistan has a similar number of people (5.9 million).

Neighbouring supplies to check before ordering pressure switches

Across the border, Germany also runs on a nominal 230 V at 50 Hz, so ratings carry over between Denmark and its neighbour; the nameplate of the equipment still decides.

Where pressure switches are used in Denmark

In Denmark, these are the jobs that most often call for pressure switches:

  • Supermarket racks and display cases
  • Refrigerated transport and containers
  • Split, VRF and packaged air conditioners
  • Condensing units and cold rooms
  • Chillers and air-cooled condensers

Klima pressure switches models

ModelTypePressure range (bar)Cut-out setting (bar)
Klima High Pressure Switch, Manual ResetHigh pressure8 to 32Adjustable
Klima High Pressure Switch, Auto ResetHigh pressure8 to 32Adjustable
Klima Low Pressure Switch, Auto ResetLow pressure-0.7 to 7Adjustable
Klima Dual Pressure Switch, HP/LPDual HP/LPHP 8 to 32, LP -0.7 to 7Adjustable

See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.

Selecting pressure switches in Denmark

  • Match the connection (flare size or capillary) to the service port you will use.
  • Take the setting from the compressor or unit manual and stay below the design pressure of the weakest component.
  • Confirm the supply first: Denmark uses 230 V at 50 Hz, so check the voltage and frequency rating of pressure switches against the equipment nameplate.
  • Ask for the datasheet and the documents your project needs; in Denmark that usually means CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations.

Keeping pressure switches reliable in Denmark

  • Test cut-out and cut-in values with a gauge manifold and nitrogen or a controlled pressure source at commissioning.

In the northern hemisphere the busiest cooling months fall in July and August; May or June is a sensible time to check pressure switches in Denmark. Controls drift over time; verify setpoints and switch points before the demanding months.

Faults to watch for

  • Frequent unexplained compressor lockouts

Which standards apply to pressure switches in Denmark

Klima pressure switches follow EN 12263 (safety switching devices for limiting pressure in refrigerating systems), IEC 60947-5-1. In Denmark, the local framework is CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations, so match the datasheet to both and ask for any conformity documents your project needs.

Ordering pressure switches for Denmark

Cargo for Denmark usually arrives through Aarhus; tell us your preferred port or delivery address with your enquiry.

The local currency is the Krone (DKK), so confirm the quotation currency and delivery terms before you order. The main languages are Danish, English, Faroese and German; this site and its enquiry form are in English.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Pressure switches in Denmark: common questions

How do I set the cut-out pressure?

Take the value from the equipment manual for the refrigerant in use and verify it with a gauge set. Never set a switch above the pressure rating of the components it protects.

What voltage should pressure switches be rated for in Denmark?

The mains supply in Denmark is 230 V, 50 Hz. Match pressure switches to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.

Which standards apply to pressure switches in Denmark?

Klima pressure switches follow EN 12263 (safety switching devices for limiting pressure in refrigerating systems), IEC 60947-5-1. In Denmark the local framework is CE marking, RoHS and, where relevant, the Pressure Equipment Directive (PED) and F-gas regulations; request the datasheet and conformity documents with your enquiry.

How are pressure switches delivered to Denmark?

Sea freight into Denmark normally clears through ports such as Aarhus, with onward delivery by road; urgent parts can travel by air.

Which cities in Denmark can I order pressure switches for?

Every listed city is covered. The largest are Copenhagen (1.2 million), Arhus (285,000), Odense (181,000), Aalborg (143,000) and Esbjerg (72,000). The country page lists the rest.

Do the neighbours of Denmark use the same mains supply?

Yes. Its only listed neighbour (Germany) runs on a nominal 230 V at 50 Hz, the same as Denmark, so the electrical rating of a part does not usually change at the border.

What local time and daylight should I plan for in Denmark?

Copenhagen keeps UTC+1, moving to UTC+2 while daylight saving applies. At 55.7° N there are about 17 h 32 min of daylight in June and about 7 h 01 min in December.

More Klima products for Denmark

Pressure switches in cities across Denmark