Klima Industries

Pressure switches for Guam

Guam is a compact market in Oceania, and its capital is Hagatna. Guam has a hot and humid tropical climate, with little variation across its small area. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.

Pressure switches are bought here mainly for offices, shops and malls as well as factories and workshops. The range below has 4 models; send an enquiry with the model code and your delivery address in Guam.

Capital
Hagatna
Population
166,000
Area
549 km²
Time zone
UTC+10 all year
Climate
Hot and humid tropical
Supply
120 V, 60 Hz
Main ports
Apra Harbor
Standards
UL / ETL listing where applicable and the National Electrical Code (NEC), as in the United States

Klima Pressure Switches (High & Low) models

All Klima products for Guam · Klima Pressure Switches (High & Low) overview

What Guam demands of pressure switches

In Guam, cooling and refrigeration work in every month of the year. Every minute an open circuit spends in humid air adds moisture, which turns into acid in the oil; fit new pressure switches last and keep the system closed until you are ready to evacuate.

In very hot weather a badly placed control keeps the compressor running; mount pressure switches out of direct sun and away from heat sources.

Guam supplies 120 V at 60 Hz, typically 120/240 V split-phase in homes and 208, 240 or 480 V three-phase in larger buildings, so check the voltage class of pressure switches against the nameplate.

Mapping demand for pressure switches in Guam

The capital is Hagatna, but the biggest listed city is Dededo Village, about 11 km away to the north-east of it; quote the delivery city on every enquiry. The table lists the largest cities in Guam with the climate stress that wears pressure switches fastest in each.

CityPeopleClimateWhat wears pressure switches first
Dededo Village45,000hot and humid tropicalsensor drift and setpoints creeping
Yigo Village21,000hot and humid tropicalsensor drift and setpoints creeping
Tamuning20,000hot and humid tropicalcondensation inside enclosures
Tamuning-Tumon-Harmon Village20,000hot and humid tropicalsensor drift and setpoints creeping
Hagatna1,051hot and humid tropicalcondensation inside enclosures

Daylight, sun angle and time in Guam

The clock in Hagatna follows UTC+10 all year.

At 13.5° N, Hagatna has about 12 h 55 min of daylight at the June solstice and about 11 h 20 min at the December solstice. The noon sun stands 80° above the horizon in June and 53° in December, and at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day.

Jobs in Guam that call for pressure switches

In Guam, these are the jobs that most often call for pressure switches:

  • Fan speed control by head pressure
  • Split, VRF and packaged air conditioners
  • Chillers and air-cooled condensers
  • Heat pump outdoor units
  • Condensing units and cold rooms

Klima pressure switches models

ModelTypePressure range (bar)Cut-out setting (bar)
Klima High Pressure Switch, Manual ResetHigh pressure8 to 32Adjustable
Klima High Pressure Switch, Auto ResetHigh pressure8 to 32Adjustable
Klima Low Pressure Switch, Auto ResetLow pressure-0.7 to 7Adjustable
Klima Dual Pressure Switch, HP/LPDual HP/LPHP 8 to 32, LP -0.7 to 7Adjustable

See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.

Selecting pressure switches in Guam

  • Use an HP switch with manual reset for safety duty and an LP switch with automatic reset for pump-down or control duty.
  • Check the electrical rating against the contactor coil or control circuit it will switch.
  • Confirm the supply first: Guam uses 120 V at 60 Hz, so check the voltage and frequency rating of pressure switches against the equipment nameplate.
  • Ask for the datasheet and the documents your project needs; in Guam that usually means UL / ETL listing where applicable and the National Electrical Code (NEC), as in the United States.

Keeping pressure switches reliable in Guam

  • Test cut-out and cut-in values with a gauge manifold and nitrogen or a controlled pressure source at commissioning.

With little seasonal change in temperature, air conditioning in Guam works almost every day. Spread checks of pressure switches through the year instead of waiting for a peak. Controls drift over time; verify setpoints and switch points before the demanding months.

Faults to watch for

  • A switch that cycles at the wrong pressure

Approvals for pressure switches sold into Guam

Klima pressure switches are specified against EN 12263 (safety switching devices for limiting pressure in refrigerating systems), IEC 60947-5-1. For import and installation in Guam, buyers also meet UL / ETL listing where applicable and the National Electrical Code (NEC), as in the United States. Ask for the datasheet and conformity documents for the Klima model you plan to specify, so that submittals and import paperwork are complete.

Ordering pressure switches for Guam

Cargo for Guam usually arrives through Apra Harbor; tell us your preferred port or delivery address with your enquiry.

The local currency is the Dollar (USD), so confirm the quotation currency and delivery terms before you order. The main languages are English and Chamorro; this site and its enquiry form are in English.

Contractors and traders can ask for trade terms through the distributors page. See the distributors page.

Questions about pressure switches in Guam

Should I choose manual or automatic reset?

Choose manual reset for safety (HP) duty, because it forces a technician to investigate. Automatic reset suits low-pressure control such as pump-down.

What voltage should pressure switches be rated for in Guam?

The supply in Guam is 120 V, 60 Hz. Residential units usually run on split-phase and commercial plant on three-phase, so confirm the voltage and phase before choosing a pressure switch.

Which standards apply to pressure switches in Guam?

Klima pressure switches follow EN 12263 (safety switching devices for limiting pressure in refrigerating systems), IEC 60947-5-1. In Guam the local framework is UL / ETL listing where applicable and the National Electrical Code (NEC), as in the United States; request the datasheet and conformity documents with your enquiry.

How are pressure switches delivered to Guam?

Sea freight into Guam normally clears through ports such as Apra Harbor, with onward delivery by road; urgent parts can travel by air.

Which cities in Guam can I order pressure switches for?

Every listed city is covered. The largest are Dededo Village (45,000), Yigo Village (21,000), Tamuning (20,000), Tamuning-Tumon-Harmon Village (20,000) and Hagatna (1,051). The country page lists the rest.

What local time and daylight should I plan for in Guam?

Hagatna keeps UTC+10 all year. At 13.5° N there are about 12 h 55 min of daylight in June and about 11 h 20 min in December.

More Klima products for Guam

Pressure switches in cities across Guam