Klima Industries

Pressure switches for Hagatna

As the capital of Guam, Hagatna is a smaller city with about 1,051 people. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.

The main users of pressure switches in Hagatna are offices, shops and malls as well as factories and workshops. The range below has 4 models; send an enquiry with the model code and your delivery address in Hagatna.

Country
Guam
Population
1,051
Climate
Hot and humid tropical
Coordinates
13.5° N, 144.7° E
Time zone
UTC+10 all year
Supply
120 V, 60 Hz
Status
National capital

Klima Pressure Switches (High & Low) models

All Klima products for Hagatna · Klima Pressure Switches (High & Low) overview

Pressure switches and the climate in Hagatna

In Hagatna, cooling and refrigeration work in every month of the year. Every minute an open circuit spends in humid air adds moisture, which turns into acid in the oil; fit new pressure switches last and keep the system closed until you are ready to evacuate.

In very hot weather a badly placed control keeps the compressor running; mount pressure switches out of direct sun and away from heat sources.

Where pressure switches go from Hagatna

Hagatna ranks 5th of the 5 listed cities in Guam and holds about 1% of the people living in them, roughly 2.3% of the size of the largest city, Dededo Village. Hagatna is the capital, and Dededo Village, the largest listed city, lies roughly 11 km to the south-west.

Nearest to Hagatna: Tamuning (4 km east), Tamuning-Tumon-Harmon Village (4 km east) and Dededo Village (11 km north-east). Four other listed cities lie within 100 km, and four within 300 km.

CityDistancePeopleWhat wears pressure switches first
Tamuning4 km east20,000condensation inside enclosures
Tamuning-Tumon-Harmon Village4 km east20,000condensation inside enclosures
Dededo Village11 km north-east45,000sensor drift and setpoints creeping
Yigo Village17 km north-east21,000condensation inside enclosures

In a smaller city like Hagatna, a replacement control can mean a long wait. Keep a spare for critical equipment and check that the range matches the original.

Daylight and sun angle in Hagatna

Local time in Hagatna is UTC+10 all year.

Hagatna lies at 13.5° N, 144.7° E. Daylight lasts about 12 h 55 min at the June solstice and about 11 h 20 min in December, with a noon sun 80° and 53° high; at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. Hagatna has a hot and humid tropical climate, the same as the country as a whole, and 4 other listed cities share it.

Typical uses of pressure switches in Hagatna

In Hagatna, these are the jobs that most often call for pressure switches:

  • Chillers and air-cooled condensers
  • Heat pump outdoor units
  • Fan speed control by head pressure

Klima pressure switches models

ModelTypePressure range (bar)Cut-out setting (bar)
Klima High Pressure Switch, Manual ResetHigh pressure8 to 32Adjustable
Klima High Pressure Switch, Auto ResetHigh pressure8 to 32Adjustable
Klima Low Pressure Switch, Auto ResetLow pressure-0.7 to 7Adjustable
Klima Dual Pressure Switch, HP/LPDual HP/LPHP 8 to 32, LP -0.7 to 7Adjustable

See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.

Selecting pressure switches in Hagatna

  • Take the setting from the compressor or unit manual and stay below the design pressure of the weakest component.
  • Confirm the supply first: Guam uses 120 V at 60 Hz, so check the voltage and frequency rating of pressure switches against the equipment nameplate.

Keeping pressure switches reliable in Hagatna

  • Test cut-out and cut-in values with a gauge manifold and nitrogen or a controlled pressure source at commissioning.

A tropical climate keeps cooling demand steady through the year in Hagatna, so there is no quiet season. Schedule checks of pressure switches around the main rainy-season changes and keep spares on hand. Checking setpoints and safety cut-outs in a quiet week is simpler than doing it during a heatwave.

Faults to watch for

  • Frequent unexplained compressor lockouts

Getting pressure switches to Hagatna

Shipments for Hagatna normally clear customs at one of the main entry points of Guam and finish the journey by road; send your delivery address with the enquiry.

National rules, standards and voltage for Guam are summarised on the country page.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Questions about pressure switches in Hagatna

What does a low pressure switch do?

It stops the compressor when suction pressure falls too low, protecting it from running with too little refrigerant and preventing evaporator icing.

What voltage should pressure switches be rated for in Hagatna?

Equipment in Guam runs from 120 V at 60 Hz; make sure the pressure switch you choose carries the right voltage and frequency rating for 60 Hz operation.

How are pressure switches delivered to Hagatna?

To order pressure switches for Hagatna, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

Which parts of Hagatna can I order for?

Enquiries are welcome from every part of Hagatna. Send the delivery address with your enquiry.

Which cities near Hagatna can the same order serve?

The listed cities closest to Hagatna are Tamuning (4 km east), Tamuning-Tumon-Harmon Village (4 km east) and Dededo Village (11 km north-east). Combine them into one order and give each delivery address.

What local time and daylight should I plan for in Hagatna?

Hagatna keeps UTC+10 all year. At 13.5° N there are about 12 h 55 min of daylight in June and about 11 h 20 min in December.

More Klima products for Hagatna

Pressure switches in cities near Hagatna