Klima Industries

Pressure switches supply in Manhica

With about 65,000 people, Manhica is a smaller city in Mozambique. Summers are hot and humid, with heavy seasonal rain, while winters are cooler and milder.

Pressure switches are bought here mainly for offices, shops and malls as well as homes and apartments. The Klima range includes 4 models, each with a specification table; send an enquiry from Manhica for a quotation.

Country
Mozambique
Population
65,000
Climate
Humid subtropical
Coordinates
25.4° S, 32.8° E
Time zone
UTC+2 all year
From Maputo
67 km north
Supply
230 V, 50 Hz

Klima Pressure Switches (High & Low) models

All Klima products for Manhica · Klima Pressure Switches (High & Low) overview

Conditions in Manhica that affect pressure switches

In Manhica, cooling demand peaks through a long, humid summer. Every minute an open circuit spends in humid air adds moisture, which turns into acid in the oil; fit new pressure switches last and keep the system closed until you are ready to evacuate.

In very hot weather a badly placed control keeps the compressor running; mount pressure switches out of direct sun and away from heat sources.

Pressure switches in Manhica and the cities near it

Among the 30 listed cities in Mozambique, Manhica comes 23rd by population, with about 0.9% of the listed urban population, roughly 5.2% of the size of the largest city, Maputo. The capital, Maputo, is about 67 km away, to the south of Manhica. For scale, Belize City in Belize has a similar population (65,000).

In the directory the nearest cities are Maputo (67 km south), Matola (71 km south-west) and Ressano Garcia (82 km west). Five other listed cities lie within 100 km, and six within 300 km. At the other extreme, Mocimboa da Praia is about 1,752 km north-east of Manhica, the furthest listed city in Mozambique.

CityDistancePeopleWhat wears pressure switches first
Maputo67 km south1.3 millionsensor drift and setpoints creeping
Matola71 km south-west1.2 millioncondensation inside enclosures
Ressano Garcia82 km west110,000sensor drift and setpoints creeping
Xai-Xai93 km north-east154,000condensation inside enclosures
Chokwe98 km north64,000condensation inside enclosures
Chibuto108 km north-east73,000condensation inside enclosures

In a smaller city like Manhica, a replacement control can mean a long wait. Keep a spare for critical equipment and check that the range matches the original.

Time zone, sun and daylight in Manhica

Manhica keeps UTC+2 all year.

Sunlight at 25.4° S (Manhica): about 10 h 33 min of daylight in June, about 13 h 43 min in December, and a noon sun that reaches 41° in June and 88° in December. The sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. Manhica has a humid subtropical climate, the same as the country as a whole, and 8 other listed cities share it.

Where pressure switches are used in Manhica

In Manhica, these are the jobs that most often call for pressure switches:

  • Split, VRF and packaged air conditioners
  • Heat pump outdoor units
  • Condensing units and cold rooms

Klima pressure switches models

ModelTypePressure range (bar)Cut-out setting (bar)
Klima High Pressure Switch, Manual ResetHigh pressure8 to 32Adjustable
Klima High Pressure Switch, Auto ResetHigh pressure8 to 32Adjustable
Klima Low Pressure Switch, Auto ResetLow pressure-0.7 to 7Adjustable
Klima Dual Pressure Switch, HP/LPDual HP/LPHP 8 to 32, LP -0.7 to 7Adjustable

See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.

How to pick pressure switches for work in Manhica

  • Choose the refrigerant and its pressure range first, because cut-out values for R410A differ greatly from those for R22 or R134a.
  • Ask for the datasheet and the documents your project needs; in Mozambique that usually means INNOQ (national standards and quality institute) requirements.

Care and maintenance in Manhica

  • Test cut-out and cut-in values with a gauge manifold and nitrogen or a controlled pressure source at commissioning.

In the southern hemisphere the busiest cooling months fall from December to March; October or November is a sensible time to check pressure switches in Manhica. Checking setpoints and safety cut-outs in a quiet week is simpler than doing it during a heatwave.

Signs of trouble

  • Frequent unexplained compressor lockouts

Ordering pressure switches for Manhica

Shipments for Manhica normally clear customs at one of the main entry points of Mozambique and finish the journey by road; send your delivery address with the enquiry.

National rules, standards and voltage for Mozambique are summarised on the country page.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Questions about pressure switches in Manhica

Should I choose manual or automatic reset?

Choose manual reset for safety (HP) duty, because it forces a technician to investigate. Automatic reset suits low-pressure control such as pump-down.

What voltage should pressure switches be rated for in Manhica?

The mains supply in Mozambique is 230 V, 50 Hz. Match pressure switches to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.

How are pressure switches delivered to Manhica?

To order pressure switches for Manhica, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

Which parts of Manhica can I order for?

Enquiries are welcome from every part of Manhica. Send the delivery address with your enquiry.

Which cities near Manhica can the same order serve?

The listed cities closest to Manhica are Maputo (67 km south), Matola (71 km south-west) and Ressano Garcia (82 km west). Combine them into one order and give each delivery address.

What local time and daylight should I plan for in Manhica?

Manhica keeps UTC+2 all year. At 25.4° S there are about 10 h 33 min of daylight in June and about 13 h 43 min in December.

More Klima products for Manhica

Pressure switches in cities near Manhica