Klima pressure switches for Xai-Xai
With about 154,000 people, Xai-Xai is a smaller city in Mozambique. Summers are hot and humid, with heavy seasonal rain, while winters are cooler and milder.
Pressure switches are bought here mainly for offices, shops and malls, homes and apartments as well as hospitals and clinics. Klima Industries lists 4 models in this range with full specifications below, and enquiries from Xai-Xai are welcome.
- Country
- Mozambique
- Population
- 154,000
- Climate
- Humid subtropical
- Coordinates
- 25.1° S, 33.6° E
- Time zone
- UTC+2 all year
- From Maputo
- 147 km north-east
- Supply
- 230 V, 50 Hz
Klima Pressure Switches (High & Low) models
- Klima High Pressure Switch, Manual Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima High Pressure Switch, Auto Reset Type: High pressure, Pressure range: 8 to 32 bar, Cut-out setting: Adjustable bar
- Klima Low Pressure Switch, Auto Reset Type: Low pressure, Pressure range: -0.7 to 7 bar, Cut-out setting: Adjustable bar
- Klima Dual Pressure Switch, HP/LP Type: Dual HP/LP, Pressure range: HP 8 to 32, LP -0.7 to 7 bar, Cut-out setting: Adjustable bar
All Klima products for Xai-Xai · Klima Pressure Switches (High & Low) overview
Conditions in Xai-Xai that affect pressure switches
In Xai-Xai, cooling demand peaks through a long, humid summer. Humid air makes moisture ingress the biggest installation risk, so keep pressure switches sealed until use, braze under nitrogen and evacuate to a deep vacuum before charging.
Sun-warmed walls make thermostats read high; place pressure switches on interior walls away from sunlight and supply air so that the set point reflects the room, not the wall.
Pressure switches in Xai-Xai and the cities near it
By population Xai-Xai is 13th of the 30 cities listed for Mozambique, with roughly 2% of their combined population, about 12% of the size of Maputo, the largest. From Maputo, the capital, Xai-Xai is roughly 147 km to the north-east. It is about the same size as Janzur in Libya, which has 154,000.
Nearest to Xai-Xai: Chibuto (42 km north), Chokwe (88 km north-west) and Manhica (93 km south-west). Three other listed cities lie within 100 km, and eight within 300 km.
| City | Distance | People | What wears pressure switches first |
|---|---|---|---|
| Chibuto | 42 km north | 73,000 | condensation inside enclosures |
| Chokwe | 88 km north-west | 64,000 | sensor drift and setpoints creeping |
| Manhica | 93 km south-west | 65,000 | sensor drift and setpoints creeping |
| Maputo | 147 km south-west | 1.3 million | sensor drift and setpoints creeping |
| Matola | 156 km south-west | 1.2 million | condensation inside enclosures |
| Ressano Garcia | 171 km west | 110,000 | sensor drift and setpoints creeping |
In a smaller city like Xai-Xai, a replacement control can mean a long wait. Keep a spare for critical equipment and check that the range matches the original.
The sun and the clock in Xai-Xai
The clock in Xai-Xai follows UTC+2 all year.
Sunlight at 25.1° S (Xai-Xai): about 10 h 35 min of daylight in June, about 13 h 42 min in December, and a noon sun that reaches 42° in June and 88° in December. The sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. The climate in Xai-Xai is humid subtropical, in line with the rest of Mozambique; 8 other listed cities share it.
Jobs in Xai-Xai that call for pressure switches
Typical work in Xai-Xai that needs pressure switches:
- Heat pump outdoor units
- Split, VRF and packaged air conditioners
- Supermarket racks and display cases
Klima pressure switches models
| Model | Type | Pressure range (bar) | Cut-out setting (bar) |
|---|---|---|---|
| Klima High Pressure Switch, Manual Reset | High pressure | 8 to 32 | Adjustable |
| Klima High Pressure Switch, Auto Reset | High pressure | 8 to 32 | Adjustable |
| Klima Low Pressure Switch, Auto Reset | Low pressure | -0.7 to 7 | Adjustable |
| Klima Dual Pressure Switch, HP/LP | Dual HP/LP | HP 8 to 32, LP -0.7 to 7 | Adjustable |
See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.
How to pick pressure switches for work in Xai-Xai
- Match the connection (flare size or capillary) to the service port you will use.
- Ask for the datasheet and the documents your project needs; in Mozambique that usually means INNOQ (national standards and quality institute) requirements.
Care and maintenance in Xai-Xai
- Replace a switch that fails to trip at the specified pressure, and do not adjust a safety switch beyond its marked range.
In the southern hemisphere the busiest cooling months fall from December to March; October or November is a sensible time to check pressure switches in Xai-Xai. Checking setpoints and safety cut-outs in a quiet week is simpler than doing it during a heatwave.
Faults to watch for
- Frequent unexplained compressor lockouts
Ordering pressure switches for Xai-Xai
Shipments for Xai-Xai normally clear customs at one of the main entry points of Mozambique and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Mozambique are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Pressure switches in Xai-Xai: common questions
How do I set the cut-out pressure?
Take the value from the equipment manual for the refrigerant in use and verify it with a gauge set. Never set a switch above the pressure rating of the components it protects.
What voltage should pressure switches be rated for in Xai-Xai?
With a 230 V, 50 Hz supply, Mozambique follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every pressure switch against the equipment it serves.
How are pressure switches delivered to Xai-Xai?
To order pressure switches for Xai-Xai, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Xai-Xai can I order for?
Enquiries are welcome from every part of Xai-Xai. Send the delivery address with your enquiry.
Which cities near Xai-Xai can the same order serve?
The listed cities closest to Xai-Xai are Chibuto (42 km north), Chokwe (88 km north-west) and Manhica (93 km south-west). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Xai-Xai?
Xai-Xai keeps UTC+2 all year. At 25.1° S there are about 10 h 35 min of daylight in June and about 13 h 42 min in December.
More Klima products for Xai-Xai
- Klima Contactors in Xai-Xai
- Klima Filter Driers in Xai-Xai
- Klima Thermometers for HVAC in Xai-Xai
- Klima Copper Coils & Tubes in Xai-Xai
- Klima Thermostats in Xai-Xai
- Klima Capacitors in Xai-Xai
Pressure switches in cities near Xai-Xai
- Klima Pressure Switches (High & Low) in Chibuto (about 42 km)
- Klima Pressure Switches (High & Low) in Chokwe (about 88 km)
- Klima Pressure Switches (High & Low) in Manhica (about 93 km)
- Klima Pressure Switches (High & Low) in Maputo (about 147 km)
- Klima Pressure Switches (High & Low) in Matola (about 156 km)