Klima Industries

Buying pressure switches in Tacna

Found in Peru, Tacna is a mid-sized city with a hot and arid climate. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.

The main users of pressure switches in Tacna are offices, shops and malls, cold stores and food distribution as well as homes and apartments. The range below has 4 models; send an enquiry with the model code and your delivery address in Tacna.

Country
Peru
Population
286,000
Climate
Hot and arid
Coordinates
18.0° S, 70.3° W
Time zone
UTC-5 all year
From Lima
985 km south-east
Supply
220 V, 60 Hz

Klima Pressure Switches (High & Low) models

All Klima products for Tacna · Klima Pressure Switches (High & Low) overview

Conditions in Tacna that affect pressure switches

In Tacna, air conditioning and refrigeration run for most of the year. In very hot weather discharge pressure climbs towards the safety limits; check that pressure switches are rated for the refrigerant in use, and keep condensers clean and fans healthy.

Fine dust builds up on sensors and in dials; a soft brush keeps pressure switches reading accurately.

Pressure switches in Tacna and the cities near it

Among the 31 listed cities in Peru, Tacna comes 11th by population, with about 1.8% of the listed urban population, roughly 3.7% of the size of the largest city, Lima. Tacna lies about 985 km south-east of Lima, the capital. It is about the same size as Butembo in DR Congo, which has 286,000.

The closest are Moquegua (116 km north-west), Arequipa (226 km north-west) and Puno (243 km north). No other listed city lies within 100 km, and four lie within 300 km. At the other extreme, Tumbes is about 1,953 km north-west of Tacna, the furthest listed city in Peru.

CityDistancePeopleWhat wears pressure switches first
Moquegua116 km north-west70,000dust in enclosures and sticky switches
Arequipa226 km north-west1.2 millionpressure settings that shift with altitude
Puno243 km north129,000pressure settings that shift with altitude
Juliaca280 km north246,000pressure settings that shift with altitude
Cusco531 km north428,000pressure settings that shift with altitude
Abancay562 km north-west72,000calibration drift between seasons

In a mid-sized city like Tacna, specific control ranges can be hard to find. Send the model or nameplate and the range you need so the right one is matched.

The sun and the clock in Tacna

Local time in Tacna is UTC-5 all year.

Sunlight at 18.0° S (Tacna): about 11 h 03 min of daylight in June, about 13 h 13 min in December, and a noon sun that reaches 49° in June and 85° in December. The sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. The climate in Tacna is hot and arid, in line with the rest of Peru; 16 other listed cities share it.

Typical uses of pressure switches in Tacna

In Tacna, these are the jobs that most often call for pressure switches:

  • Condensing units and cold rooms
  • Heat pump outdoor units
  • Supermarket racks and display cases

Klima pressure switches models

ModelTypePressure range (bar)Cut-out setting (bar)
Klima High Pressure Switch, Manual ResetHigh pressure8 to 32Adjustable
Klima High Pressure Switch, Auto ResetHigh pressure8 to 32Adjustable
Klima Low Pressure Switch, Auto ResetLow pressure-0.7 to 7Adjustable
Klima Dual Pressure Switch, HP/LPDual HP/LPHP 8 to 32, LP -0.7 to 7Adjustable

See the full Klima Pressure Switches (High & Low) range for specifications, standards and a plain-language guide to choosing the right part.

Selecting pressure switches in Tacna

  • Check the electrical rating against the contactor coil or control circuit it will switch.
  • For hot and arid conditions in Tacna, favour higher temperature ratings and some margin on every rated value.

Keeping pressure switches reliable in Tacna

  • Test cut-out and cut-in values with a gauge manifold and nitrogen or a controlled pressure source at commissioning.

Tacna lies in the southern hemisphere, where cooling demand usually peaks from November to March. Schedule inspections of pressure switches for September or October, ahead of that peak. Calibrate and test controls under easy conditions so settings are proven before the load rises.

Faults to watch for

  • A switch that cycles at the wrong pressure

Supply and delivery to Tacna

To order pressure switches for Tacna, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

National rules, standards and voltage for Peru are summarised on the country page.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Pressure switches in Tacna: common questions

How do I set the cut-out pressure?

Take the value from the equipment manual for the refrigerant in use and verify it with a gauge set. Never set a switch above the pressure rating of the components it protects.

What voltage should pressure switches be rated for in Tacna?

Peru uses 220 V at 60 Hz, so check that pressure switches are rated for that voltage and for 60 Hz operation before you order.

How are pressure switches delivered to Tacna?

Shipments for Tacna normally clear customs at one of the main entry points of Peru and finish the journey by road; send your delivery address with the enquiry.

Which parts of Tacna can I order for?

Enquiries are welcome from every part of Tacna. Send the delivery address with your enquiry.

Which cities near Tacna can the same order serve?

The listed cities closest to Tacna are Moquegua (116 km north-west), Arequipa (226 km north-west) and Puno (243 km north). Combine them into one order and give each delivery address.

What local time and daylight should I plan for in Tacna?

Tacna keeps UTC-5 all year. At 18.0° S there are about 11 h 03 min of daylight in June and about 13 h 13 min in December.

More Klima products for Tacna

Pressure switches in cities near Tacna