Klima Contactors in Bahir Dar
With about 350,000 people, Bahir Dar is a mid-sized city in Ethiopia. Temperatures stay high all year, typically from the high 20s to the mid 30s °C, with humidity often above 75 %.
Demand for contactors comes mostly from offices, shops and malls as well as homes and apartments. The Klima range includes 7 models, each with a specification table; send an enquiry from Bahir Dar for a quotation.
- Country
- Ethiopia
- Population
- 350,000
- Climate
- Hot and humid tropical
- Coordinates
- 11.6° N, 37.4° E
- Time zone
- UTC+3 all year
- From Addis Ababa
- 322 km north-west
- Supply
- 230 V, 50 Hz
Klima Contactors models
- Klima 2-Pole Contactor 25 A, 24 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 2-Pole Contactor 25 A, 230 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 25 A, 24 V Coil Poles: 3, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 24 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 230 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 40 A, 230 V Coil Poles: 3, Rated current: 40 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 63 A, 230 V Coil Poles: 3, Rated current: 63 A, Coil voltage: 230 V AC
All Klima products for Bahir Dar · Klima Contactors overview
What Bahir Dar demands of contactors
In Bahir Dar, cooling and refrigeration work in every month of the year. Damp air can track across dirty or unprotected connections; fit contactors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Heat is the main enemy of electrical parts here: contactors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Contactors in Bahir Dar and the cities near it
By population Bahir Dar is 8th of the 50 cities listed for Ethiopia, with roughly 2.9% of their combined population, roughly 9.1% of the size of the largest city, Addis Ababa. The capital, Addis Ababa, is about 322 km away, to the south-east of Bahir Dar. For scale, Diepsloot in South Africa has a similar population (350,000).
Nearest to Bahir Dar: Debre Tabor (74 km north-east), Gonder (112 km north) and Debre Mark'os (143 km south). One other listed city lies within 100 km, and 10 within 300 km. The farthest listed city in Ethiopia is Warder, about 1,012 km south-east of Bahir Dar.
| City | Distance | People | What wears contactors first |
|---|---|---|---|
| Debre Tabor | 74 km north-east | 125,000 | terminals loosening and parts running hot |
| Gonder | 112 km north | 466,000 | moisture on terminals and corrosion |
| Debre Mark'os | 143 km south | 141,000 | moisture on terminals and corrosion |
| Weldiya | 241 km east | 104,000 | moisture on terminals and corrosion |
| Dessie | 250 km east | 270,000 | terminals loosening and parts running hot |
| Alamata | 253 km east | 70,000 | terminals loosening and parts running hot |
A mid-sized city like Bahir Dar may not hold every rating in stock, so group your needs into one order and send the nameplate details for each part.
The sun and the clock in Bahir Dar
The clock in Bahir Dar follows UTC+3 all year.
Bahir Dar lies at 11.6° N, 37.4° E. Daylight lasts about 12 h 48 min at the June solstice and about 11 h 27 min in December, with a noon sun 78° and 55° high; at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. Bahir Dar has a hot and humid tropical climate, which differs from the highland climate that describes Ethiopia overall; 48 other listed cities share it.
Typical uses of contactors in Bahir Dar
In Bahir Dar, these are the jobs that most often call for contactors:
- Heat pump defrost and reversing controls
- Compressor control in split and packaged air conditioners
- Condenser fan switching
Klima contactors models
| Model | Poles | Rated current (A) | Coil voltage (V) |
|---|---|---|---|
| Klima 2-Pole Contactor 25 A, 24 V Coil | 2 | 25 | 24 V AC |
| Klima 2-Pole Contactor 25 A, 230 V Coil | 2 | 25 | 230 V AC |
| Klima 3-Pole Contactor 25 A, 24 V Coil | 3 | 25 | 24 V AC |
| Klima 3-Pole Contactor 32 A, 24 V Coil | 3 | 32 | 24 V AC |
See the full Klima Contactors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting contactors in Bahir Dar
- Allow headroom for hot enclosures, because contactors derate in high ambient temperatures.
- Ask for the datasheet and the documents your project needs; in Ethiopia that usually means Ethiopian Standards Agency (ESA) requirements.
Care and maintenance in Bahir Dar
- Keep dust, insects and moisture out of the control box, and remember that a chattering contactor often points to low control voltage.
With little seasonal change in temperature, air conditioning in Bahir Dar works almost every day. Spread checks of contactors through the year instead of waiting for a peak. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Faults to watch for
- A buzzing or chattering contactor
Ordering contactors for Bahir Dar
To order contactors for Bahir Dar, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
National rules, standards and voltage for Ethiopia are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Questions about contactors in Bahir Dar
How often should contactors be replaced?
There is no fixed interval. Replace them when the contacts show pitting or heat discolouration, or at the first sign of intermittent starting. Frequent cycling shortens life.
What voltage should contactors be rated for in Bahir Dar?
Ethiopia supplies 230 V at 50 Hz, the common 230/400 V, 50 Hz pattern, so contactors rated for 230 V single-phase and 400 V three-phase equipment are the usual choice.
How are contactors delivered to Bahir Dar?
Shipments for Bahir Dar normally clear customs at one of the main entry points of Ethiopia and finish the journey by road; send your delivery address with the enquiry.
Which parts of Bahir Dar can I order for?
Enquiries are welcome from every part of Bahir Dar. Send the delivery address with your enquiry.
What local time and daylight should I plan for in Bahir Dar?
Bahir Dar keeps UTC+3 all year. At 11.6° N there are about 12 h 48 min of daylight in June and about 11 h 27 min in December.
Which cities near Bahir Dar can the same order serve?
The listed cities closest to Bahir Dar are Debre Tabor (74 km north-east), Gonder (112 km north) and Debre Mark'os (143 km south). Combine them into one order and give each delivery address.
More Klima products for Bahir Dar
- Klima Capacitors in Bahir Dar
- Klima Delay on Make Timer in Bahir Dar
- Klima Transformer for HVAC in Bahir Dar
- Klima Map Gas (Brazing & Welding) in Bahir Dar
- Klima Thermostats in Bahir Dar
- Klima Filter Driers in Bahir Dar