Magliana, Rome: Klima Contactors
Magliana is an industrial area in Rome, Italy. Typical customers are maintenance contractors, plant operators and workshops, and what they want is exact-match replacements, fast turnaround and trade quantities.
The main users of contactors in Magliana, Rome are factories and workshops as well as cold stores and food distribution. The range below has 7 models; send an enquiry with the model code and your delivery address in Magliana, Rome.
- Area type
- Industrial area
- City
- Rome
- Country
- Italy
- Climate
- Mediterranean
- Supply
- 230 V, 50 Hz
Klima Contactors models
- Klima 2-Pole Contactor 25 A, 24 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 2-Pole Contactor 25 A, 230 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 25 A, 24 V Coil Poles: 3, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 24 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 230 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 40 A, 230 V Coil Poles: 3, Rated current: 40 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 63 A, 230 V Coil Poles: 3, Rated current: 63 A, Coil voltage: 230 V AC
All Klima products for Magliana, Rome ยท Klima Contactors overview
Conditions in Magliana, Rome that affect contactors
In Magliana, Rome, cooling demand peaks from late spring to early autumn. Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; contactors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.
Large temperature swings expand and contract terminals every day, which gradually loosens connections, so re-tighten the terminals of contactors during each seasonal service.
About supply to Magliana, Rome
Magliana is one of 9 areas listed for Rome; others include Trastevere, Centocelle, San Lorenzo and Tiburtina. Rome has about 2.3 million people, the national capital.
Industrial users in Magliana switch heavy motor loads many times a day, so contactors and capacitors need generous duty ratings and tight terminals, not just a matching nameplate.
Where Magliana fits in Rome
Magliana is one of 9 areas listed for Rome, and one of 2 classed as industrial areas. More industrial areas in Rome, each with its own page, include Tiburtina. The rest of the areas listed for Rome are Centocelle, EUR, Fiumicino, Prati and Trastevere.
Where contactors are used in Magliana, Rome
Contactors are most often specified in Magliana, Rome for:
- Condenser fan switching
- Pump and ventilation motor control
- Lighting and general power switching in plant rooms
Klima contactors models
| Model | Poles | Rated current (A) | Coil voltage (V) |
|---|---|---|---|
| Klima 2-Pole Contactor 25 A, 24 V Coil | 2 | 25 | 24 V AC |
| Klima 2-Pole Contactor 25 A, 230 V Coil | 2 | 25 | 230 V AC |
| Klima 3-Pole Contactor 25 A, 24 V Coil | 3 | 25 | 24 V AC |
| Klima 3-Pole Contactor 32 A, 24 V Coil | 3 | 32 | 24 V AC |
See the full Klima Contactors range for specifications, standards and a plain-language guide to choosing the right part.
How to pick contactors for work in Magliana, Rome
- Size by motor current, not by horsepower alone. Use the compressor nameplate RLA and LRA, and choose a contactor with a rated operating current above them.
- Confirm the supply first: Italy uses 230 V at 50 Hz, so check the voltage and frequency rating of contactors against the equipment nameplate.
Keeping contactors reliable in Magliana, Rome
- Keep dust, insects and moisture out of the control box, and remember that a chattering contactor often points to low control voltage.
Because Magliana, Rome is in the northern hemisphere, the heaviest cooling load normally falls from June to September. Service contactors in April or May, while the load is still light. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Signs of trouble
- Burnt or welded contacts that keep the unit running when switched off
Supply and delivery to Magliana, Rome
Send the delivery address in Magliana, or a collection point in Rome, together with the model and quantity you need.
National rules, standards and voltage for Italy are summarised on the country page.
Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.
Contactors in Magliana, Rome: common questions
Can I replace a contactor with a higher amp rating?
Yes. A higher rated current is safe and usually longer lasting, provided the coil voltage, pole count and physical size suit the installation.
What voltage should contactors be rated for in Magliana, Rome?
With a 230 V, 50 Hz supply, Italy follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every contactor against the equipment it serves.
How are contactors delivered to Magliana, Rome?
Deliveries for Magliana are arranged to Rome; give a street address or a collection point in your enquiry.
What do buyers in Magliana usually need?
Magliana is an industrial area, so the buyers are mostly maintenance contractors, plant operators and workshops. They want exact-match replacements, fast turnaround and trade quantities.
More Klima products for Magliana, Rome
- Klima Capacitors in Magliana, Rome
- Klima Delay on Make Timer in Magliana, Rome
- Klima Transformer for HVAC in Magliana, Rome
- Klima Drier Core 48-KL in Magliana, Rome
- Klima Pressure Switches (High & Low) in Magliana, Rome
- Klima Temperature Controllers in Magliana, Rome