Klima Industries

Klima contactors for Tulkarm

Found in Palestine, Tulkarm is a smaller city with a Mediterranean climate. Summers are hot and dry, with long spells above 30 °C, and winters are mild and wetter.

The main users of contactors in Tulkarm are offices, shops and malls, factories and workshops as well as homes and apartments. The Klima range includes 7 models, each with a specification table; send an enquiry from Tulkarm for a quotation.

Country
Palestine
Population
44,000
Climate
Mediterranean
Coordinates
32.3° N, 35.0° E
Time zone
UTC+2, moving to UTC+3 while daylight saving applies
From Ramallah
49 km north
Supply
230 V, 50 Hz

Klima Contactors models

All Klima products for Tulkarm · Klima Contactors overview

Conditions in Tulkarm that affect contactors

In Tulkarm, cooling demand peaks from late spring to early autumn. Heat is the main enemy of electrical parts here: contactors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.

Daily heating and cooling cycles work screwed and crimped connections loose over time; check the torque on the terminals of contactors at least once a year.

Contactors in Tulkarm and the cities near it

Tulkarm ranks 8th of the 15 listed cities in Palestine and holds about 2.4% of the people living in them, about 10% of the size of East Jerusalem, the largest. Tulkarm lies about 49 km north of Ramallah, the capital. It is about the same size as Fenoarivo Atsinanana in Madagascar, which has 44,000.

Nearest to Tulkarm: Qalqilyah (15 km south), Nablus (24 km south-east) and Qabatiyah (26 km north-east). 10 other listed cities lie within 100 km, and 14 within 300 km.

CityDistancePeopleWhat wears contactors first
Qalqilyah15 km south43,000terminals loosening and parts running hot
Nablus24 km south-east130,000expansion and contraction loosening joints
Qabatiyah26 km north-east19,000expansion and contraction loosening joints
Al Yamun27 km north-east16,000terminals loosening and parts running hot
Janin31 km north-east35,000expansion and contraction loosening joints
Tubas32 km east16,000terminals loosening and parts running hot

In a smaller city like Tulkarm, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.

The sun and the clock in Tulkarm

Local time in Tulkarm is UTC+2, moving to UTC+3 while daylight saving applies.

At 32.3° N, Tulkarm has about 14 h 16 min of daylight at the June solstice and about 10 h 02 min at the December solstice. The noon sun stands 81° above the horizon in June and 34° in December, and at its highest the sun stands almost overhead, so roof-mounted condensing units take its full heat for much of the day. The climate in Tulkarm is Mediterranean, in line with the rest of Palestine; 14 other listed cities share it.

Typical uses of contactors in Tulkarm

Contactors are most often specified in Tulkarm for:

  • Compressor control in split and packaged air conditioners
  • Condenser fan switching
  • Chiller and air handling unit starter panels

Klima contactors models

ModelPolesRated current (A)Coil voltage (V)
Klima 2-Pole Contactor 25 A, 24 V Coil22524 V AC
Klima 2-Pole Contactor 25 A, 230 V Coil225230 V AC
Klima 3-Pole Contactor 25 A, 24 V Coil32524 V AC
Klima 3-Pole Contactor 32 A, 24 V Coil33224 V AC

See the full Klima Contactors range for specifications, standards and a plain-language guide to choosing the right part.

How to pick contactors for work in Tulkarm

  • Allow headroom for hot enclosures, because contactors derate in high ambient temperatures.
  • Ask for the datasheet and the documents your project needs; in Palestine that usually means PSI (Palestine Standards Institution) requirements.

Care and maintenance in Tulkarm

  • Inspect contacts at each seasonal service; blackened, pitted or welded contacts mean replace, never file.

In the northern hemisphere the busiest cooling months fall from June to September; April or May is a sensible time to check contactors in Tulkarm. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.

Signs of trouble

  • Burnt or welded contacts that keep the unit running when switched off

Getting contactors to Tulkarm

Shipments for Tulkarm normally clear customs at one of the main entry points of Palestine and finish the journey by road; send your delivery address with the enquiry.

National rules, standards and voltage for Palestine are summarised on the country page.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Questions about contactors in Tulkarm

Why does my contactor buzz?

Buzzing usually means low coil voltage, a dirty or worn magnetic core or a loose connection. Measure the voltage at the coil while the unit is calling for cooling.

What voltage should contactors be rated for in Tulkarm?

With a 230 V, 50 Hz supply, Palestine follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every contactor against the equipment it serves.

How are contactors delivered to Tulkarm?

To order contactors for Tulkarm, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

Which parts of Tulkarm can I order for?

Enquiries are welcome from every part of Tulkarm. Send the delivery address with your enquiry.

What local time and daylight should I plan for in Tulkarm?

Tulkarm keeps UTC+2, moving to UTC+3 while daylight saving applies. At 32.3° N there are about 14 h 16 min of daylight in June and about 10 h 02 min in December.

Which cities near Tulkarm can the same order serve?

The listed cities closest to Tulkarm are Qalqilyah (15 km south), Nablus (24 km south-east) and Qabatiyah (26 km north-east). Combine them into one order and give each delivery address.

More Klima products for Tulkarm

Contactors in cities near Tulkarm