Klima contactors for First Industrial City, Riyadh
First Industrial City is an industrial area in Riyadh, Saudi Arabia. Typical customers are maintenance contractors, plant operators and workshops, and what they want is exact-match replacements, fast turnaround and trade quantities.
Contactors are bought here mainly for factories and workshops as well as cold stores and food distribution. Klima Industries lists 7 models in this range with full specifications below, and enquiries from First Industrial City, Riyadh are welcome.
- Area type
- Industrial area
- City
- Riyadh
- Country
- Saudi Arabia
- Climate
- Hot and arid
- Supply
- 127/220 V, 60 Hz
Klima Contactors models
- Klima 2-Pole Contactor 25 A, 24 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 2-Pole Contactor 25 A, 230 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 25 A, 24 V Coil Poles: 3, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 24 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 230 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 40 A, 230 V Coil Poles: 3, Rated current: 40 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 63 A, 230 V Coil Poles: 3, Rated current: 63 A, Coil voltage: 230 V AC
All Klima products for First Industrial City, Riyadh ยท Klima Contactors overview
Contactors and the climate in First Industrial City, Riyadh
In First Industrial City, Riyadh, air conditioning and refrigeration run for most of the year. Heat is the main enemy of electrical parts here: contactors run hotter in outdoor units, so choose a higher temperature class and some rating margin, and re-check terminal tightness before each cooling season.
Fine dust settles on contactors and the surrounding wiring, traps heat and can bridge connections, so wipe it away at each service and keep covers and gland plates sealed.
Local facts for First Industrial City, Riyadh
First Industrial City is one of 11 areas listed for Riyadh; others include Al Sulay, King Abdullah Financial District, Al Murabba and Al Yarmuk. Riyadh has about 4.2 million people, the national capital.
Industrial users in First Industrial City switch heavy motor loads many times a day, so contactors and capacitors need generous duty ratings and tight terminals, not just a matching nameplate.
First Industrial City among the areas of Riyadh
First Industrial City is one of 11 areas listed for Riyadh, and one of 3 classed as industrial areas. More industrial areas in Riyadh, each with its own page, include Second Industrial City and Al Sulay. Elsewhere in Riyadh the directory also names Al Nakheel, Al Malaz, Al Yarmuk, Al Batha and Al Rawdah.
Jobs in First Industrial City, Riyadh that call for contactors
In First Industrial City, Riyadh, these are the jobs that most often call for contactors:
- Condenser fan switching
- Lighting and general power switching in plant rooms
- Chiller and air handling unit starter panels
Klima contactors models
| Model | Poles | Rated current (A) | Coil voltage (V) |
|---|---|---|---|
| Klima 2-Pole Contactor 25 A, 24 V Coil | 2 | 25 | 24 V AC |
| Klima 2-Pole Contactor 25 A, 230 V Coil | 2 | 25 | 230 V AC |
| Klima 3-Pole Contactor 25 A, 24 V Coil | 3 | 25 | 24 V AC |
| Klima 3-Pole Contactor 32 A, 24 V Coil | 3 | 32 | 24 V AC |
See the full Klima Contactors range for specifications, standards and a plain-language guide to choosing the right part.
Choosing contactors for First Industrial City, Riyadh
- Match the coil voltage exactly to the control supply. 24 V AC thermostat circuits are the most common.
- Confirm the supply first: Saudi Arabia uses 127/220 V at 60 Hz, so check the voltage and frequency rating of contactors against the equipment nameplate.
Keeping contactors reliable in First Industrial City, Riyadh
- Tighten power terminals to the torque on the datasheet; loose lugs cause heat and buzzing.
In the northern hemisphere the busiest cooling months fall from May to September; March or April is a sensible time to check contactors in First Industrial City, Riyadh. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.
Faults to watch for
- A compressor that will not start although the thermostat is calling for cooling
Getting contactors to First Industrial City, Riyadh
Deliveries for First Industrial City are arranged to Riyadh; give a street address or a collection point in your enquiry.
National rules, standards and voltage for Saudi Arabia are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about contactors in First Industrial City, Riyadh
Can I replace a contactor with a higher amp rating?
Yes. A higher rated current is safe and usually longer lasting, provided the coil voltage, pole count and physical size suit the installation.
What voltage should contactors be rated for in First Industrial City, Riyadh?
Saudi Arabia uses 127/220 V at 60 Hz, so check that contactors are rated for that voltage and for 60 Hz operation before you order.
How are contactors delivered to First Industrial City, Riyadh?
Send the delivery address in First Industrial City, or a collection point in Riyadh, together with the model and quantity you need.
What do buyers in First Industrial City usually need?
First Industrial City is an industrial area, so the buyers are mostly maintenance contractors, plant operators and workshops. They want exact-match replacements, fast turnaround and trade quantities.
More Klima products for First Industrial City, Riyadh
- Klima Capacitors in First Industrial City, Riyadh
- Klima Delay on Make Timer in First Industrial City, Riyadh
- Klima Transformer for HVAC in First Industrial City, Riyadh
- Klima Filter Driers in First Industrial City, Riyadh
- Klima Condensate Pump in First Industrial City, Riyadh
- Klima PVC Tapes in First Industrial City, Riyadh