Klima Industries

Etwatwa: Klima Contactors

With about 152,000 people, Etwatwa is a smaller city in South Africa. Altitude keeps days warm rather than hot and nights cool, with a large daily temperature range.

The main users of contactors in Etwatwa are offices, shops and malls as well as factories and workshops. The range below has 7 models; send an enquiry with the model code and your delivery address in Etwatwa.

Country
South Africa
Population
152,000
Climate
Highland
Coordinates
26.1° S, 28.5° E
Time zone
UTC+2 all year
From Pretoria
50 km south-east
Supply
230 V, 50 Hz

Klima Contactors models

All Klima products for Etwatwa · Klima Contactors overview

Contactors and the climate in Etwatwa

In Etwatwa, cooling demand is moderate, and refrigeration and process loads stay steady all year. Thinner air reduces convective cooling, so contactors in outdoor panels run warmer than the same part at sea level; derate where the datasheet advises it.

Daily heating and cooling cycles work screwed and crimped connections loose over time; check the torque on the terminals of contactors at least once a year.

Where contactors go from Etwatwa

Etwatwa ranks 37th of the 38 listed cities in South Africa and holds about 0.5% of the people living in them, about 1.6% of the size of Johannesburg, the largest. Etwatwa lies about 50 km south-east of Pretoria, the capital. It is about the same size as Stavanger in Norway, which has 152,000.

The closest are Benoni (15 km south-west), Brakpan (15 km south-west) and Thembisa (27 km north-west). 13 other listed cities lie within 100 km, and 22 within 300 km.

CityDistancePeopleWhat wears contactors first
Benoni15 km south-west605,000reduced cooling and thinner air at altitude
Brakpan15 km south-west306,000expansion and contraction loosening joints
Thembisa27 km north-west512,000expansion and contraction loosening joints
Johannesburg42 km west9.4 millionreduced cooling and thinner air at altitude
Diepsloot49 km north-west350,000expansion and contraction loosening joints
Pretoria50 km north-west2.1 millionexpansion and contraction loosening joints

In a smaller city like Etwatwa, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.

Daylight and sun angle in Etwatwa

The clock in Etwatwa follows UTC+2 all year.

At 26.1° S, Etwatwa has about 10 h 30 min of daylight at the June solstice and about 13 h 47 min at the December solstice. The noon sun stands 40° above the horizon in June and 87° in December, and the sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. The climate in Etwatwa is highland, in line with the rest of South Africa; 18 other listed cities share it.

Typical uses of contactors in Etwatwa

Typical work in Etwatwa that needs contactors:

  • Chiller and air handling unit starter panels
  • Compressor control in split and packaged air conditioners
  • Condenser fan switching

Klima contactors models

ModelPolesRated current (A)Coil voltage (V)
Klima 2-Pole Contactor 25 A, 24 V Coil22524 V AC
Klima 2-Pole Contactor 25 A, 230 V Coil225230 V AC
Klima 3-Pole Contactor 25 A, 24 V Coil32524 V AC
Klima 3-Pole Contactor 32 A, 24 V Coil33224 V AC

See the full Klima Contactors range for specifications, standards and a plain-language guide to choosing the right part.

How to pick contactors for work in Etwatwa

  • Size by motor current, not by horsepower alone. Use the compressor nameplate RLA and LRA, and choose a contactor with a rated operating current above them.
  • Confirm the supply first: South Africa uses 230 V at 50 Hz, so check the voltage and frequency rating of contactors against the equipment nameplate.

Care and maintenance in Etwatwa

  • Inspect contacts at each seasonal service; blackened, pitted or welded contacts mean replace, never file.

Altitude moderates the heat in Etwatwa, but the load follows the dry and rainy seasons and the sun. Check contactors at the change of season and keep spares for peak periods. Weak electrical parts show up first at the start of a hot spell; checking them beforehand avoids emergency call-outs.

Signs of trouble

  • A compressor that will not start although the thermostat is calling for cooling

Supply and delivery to Etwatwa

Shipments for Etwatwa normally clear customs at one of the main entry points of South Africa and finish the journey by road; send your delivery address with the enquiry.

National rules, standards and voltage for South Africa are summarised on the country page.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Questions about contactors in Etwatwa

What does the number of poles mean?

A pole is one switched circuit. A 2-pole contactor breaks both line wires of a single-phase supply, while a 3-pole contactor breaks all three phases of a three-phase supply.

What voltage should contactors be rated for in Etwatwa?

With a 230 V, 50 Hz supply, South Africa follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every contactor against the equipment it serves.

How are contactors delivered to Etwatwa?

To order contactors for Etwatwa, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

Which parts of Etwatwa can I order for?

Enquiries are welcome from every part of Etwatwa. Send the delivery address with your enquiry.

What local time and daylight should I plan for in Etwatwa?

Etwatwa keeps UTC+2 all year. At 26.1° S there are about 10 h 30 min of daylight in June and about 13 h 47 min in December.

Which cities near Etwatwa can the same order serve?

The listed cities closest to Etwatwa are Benoni (15 km south-west), Brakpan (15 km south-west) and Thembisa (27 km north-west). Combine them into one order and give each delivery address.

More Klima products for Etwatwa

Contactors in cities near Etwatwa