Contactors supply in Bern
Bern is the capital of Switzerland and a smaller city. The climate is temperate. Summers are warm rather than extreme and winters are cool, so heating matters as much as cooling.
Demand for contactors comes mostly from offices, shops and malls, factories and workshops as well as homes and apartments. Klima Industries lists 7 models in this range with full specifications below, and enquiries from Bern are welcome.
- Country
- Switzerland
- Population
- 122,000
- Climate
- Temperate
- Coordinates
- 46.9° N, 7.4° E
- Time zone
- UTC+1, moving to UTC+2 while daylight saving applies
- Supply
- 230 V, 50 Hz
- Status
- National capital
Klima Contactors models
- Klima 2-Pole Contactor 25 A, 24 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 2-Pole Contactor 25 A, 230 V Coil Poles: 2, Rated current: 25 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 25 A, 24 V Coil Poles: 3, Rated current: 25 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 24 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 24 V AC
- Klima 3-Pole Contactor 32 A, 230 V Coil Poles: 3, Rated current: 32 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 40 A, 230 V Coil Poles: 3, Rated current: 40 A, Coil voltage: 230 V AC
- Klima 3-Pole Contactor 63 A, 230 V Coil Poles: 3, Rated current: 63 A, Coil voltage: 230 V AC
All Klima products for Bern · Klima Contactors overview
What Bern demands of contactors
In Bern, cooling demand is seasonal, with short hot spells that stress equipment. Daily heating and cooling cycles work screwed and crimped connections loose over time; check the torque on the terminals of contactors at least once a year.
Damp air can track across dirty or unprotected connections; fit contactors with proper insulation and boots, and treat green corrosion on terminals as a reason to replace the part.
Where contactors go from Bern
Bern ranks 5th of the 20 listed cities in Switzerland and holds about 6.7% of the people living in them, roughly 29% of the size of the largest city, Zurich. As the national capital, Bern is about 95 km south-west of Zurich, the largest listed city. It is about the same size as San Pedro de la Paz in Chile, which has 122,000.
The closest are Biel/Bienne (26 km north-west), Thun (26 km south-east) and Fribourg (28 km south-west). 11 other listed cities lie within 100 km, and 19 within 300 km. At the other extreme, Chur is about 159 km east of Bern, the furthest listed city in Switzerland.
| City | Distance | People | What wears contactors first |
|---|---|---|---|
| Biel/Bienne | 26 km north-west | 55,000 | moisture on terminals and corrosion |
| Thun | 26 km south-east | 44,000 | expansion and contraction loosening joints |
| Fribourg | 28 km south-west | 38,000 | moisture on terminals and corrosion |
| Neuchatel | 39 km west | 33,000 | moisture on terminals and corrosion |
| La Chaux-de-Fonds | 50 km west | 38,000 | moisture on terminals and corrosion |
| Yverdon-les-Bains | 64 km west | 30,000 | expansion and contraction loosening joints |
In a smaller city like Bern, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.
Time zone, sun and daylight in Bern
Bern keeps UTC+1, moving to UTC+2 while daylight saving applies.
Bern lies at 46.9° N, 7.4° E. Daylight lasts about 15 h 53 min at the June solstice and about 8 h 31 min in December, with a noon sun 66° and 20° high; the sun climbs high in summer, so shade and ventilation around outdoor units matter. The climate in Bern is temperate, in line with the rest of Switzerland; 19 other listed cities share it.
Typical uses of contactors in Bern
Typical work in Bern that needs contactors:
- Chiller and air handling unit starter panels
- Compressor control in split and packaged air conditioners
- Heat pump defrost and reversing controls
Klima contactors models
| Model | Poles | Rated current (A) | Coil voltage (V) |
|---|---|---|---|
| Klima 2-Pole Contactor 25 A, 24 V Coil | 2 | 25 | 24 V AC |
| Klima 2-Pole Contactor 25 A, 230 V Coil | 2 | 25 | 230 V AC |
| Klima 3-Pole Contactor 25 A, 24 V Coil | 3 | 25 | 24 V AC |
| Klima 3-Pole Contactor 32 A, 24 V Coil | 3 | 32 | 24 V AC |
See the full Klima Contactors range for specifications, standards and a plain-language guide to choosing the right part.
Selecting contactors in Bern
- Size by motor current, not by horsepower alone. Use the compressor nameplate RLA and LRA, and choose a contactor with a rated operating current above them.
- For temperate conditions in Bern, allow for wide seasonal temperature swings.
Care and maintenance in Bern
- Inspect contacts at each seasonal service; blackened, pitted or welded contacts mean replace, never file.
Because Bern is in the northern hemisphere, the heaviest cooling load normally falls in July and August. Service contactors in May or June, while the load is still light. Electrical parts fail most often when the load is highest, so retighten and test before the peak.
Faults to watch for
- A compressor that will not start although the thermostat is calling for cooling
Getting contactors to Bern
Shipments for Bern normally clear customs at one of the main entry points of Switzerland and finish the journey by road; send your delivery address with the enquiry.
National rules, standards and voltage for Switzerland are summarised on the country page.
Contractors and traders can ask for trade terms through the distributors page. See the distributors page.
Questions about contactors in Bern
What coil voltage should I choose?
Use the voltage of the control circuit that energises the coil: 24 V AC in most thermostat systems, or 110/120 V or 220/240 V where the control circuit runs from mains voltage.
What voltage should contactors be rated for in Bern?
With a 230 V, 50 Hz supply, Switzerland follows the standard 230/400 V, 50 Hz arrangement; check the rated voltage on every contactor against the equipment it serves.
How are contactors delivered to Bern?
To order contactors for Bern, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.
Which parts of Bern can I order for?
Enquiries are welcome from every part of Bern. Send the delivery address with your enquiry.
Which cities near Bern can the same order serve?
The listed cities closest to Bern are Biel/Bienne (26 km north-west), Thun (26 km south-east) and Fribourg (28 km south-west). Combine them into one order and give each delivery address.
What local time and daylight should I plan for in Bern?
Bern keeps UTC+1, moving to UTC+2 while daylight saving applies. At 46.9° N there are about 15 h 53 min of daylight in June and about 8 h 31 min in December.
More Klima products for Bern
- Klima Capacitors in Bern
- Klima Delay on Make Timer in Bern
- Klima Transformer for HVAC in Bern
- Klima Copper Coils & Tubes in Bern
- Klima Condensate Pump in Bern
- Klima Pressure Switches (High & Low) in Bern