Klima Industries

Buying contactors in Ataq

With about 37,000 people, Ataq is a smaller city in Yemen. Summer daytime temperatures commonly pass 40 °C, and equipment in direct sun runs far hotter than the air.

Demand for contactors comes mostly from offices, shops and malls, factories and workshops as well as homes and apartments. The Klima range includes 7 models, each with a specification table; send an enquiry from Ataq for a quotation.

Country
Yemen
Population
37,000
Climate
Hot and arid
Coordinates
14.5° N, 46.8° E
Time zone
UTC+3 all year
From Sanaa
296 km east
Supply
230 V, 50 Hz

Klima Contactors models

All Klima products for Ataq · Klima Contactors overview

What Ataq demands of contactors

In Ataq, air conditioning and refrigeration run for most of the year. Outdoor units sit in direct sun, which raises component temperatures well above the air temperature; contactors with generous ratings and secure terminations last longer than parts chosen to the bare nameplate value.

Dust and sand work their way into outdoor control boxes; closed covers, intact gaskets and regular cleaning keep contactors cooler and connections reliable.

Where contactors go from Ataq

Ataq ranks 14th of the 22 listed cities in Yemen and holds about 0.6% of the people living in them, about 1.9% of the size of Sanaa, the largest. The capital, Sanaa, is about 296 km away, to the west of Ataq. For scale, Banjul in the Gambia has a similar population (37,000).

Nearest to Ataq: Al Bayda (149 km south-west), Ma'rib (192 km north-west) and Zinjibar (222 km south-west). No other listed city lies within 100 km, and 12 lie within 300 km. At the other extreme, Sa'dah is about 423 km north-west of Ataq, the furthest listed city in Yemen.

CityDistancePeopleWhat wears contactors first
Al Bayda149 km south-west38,000dust on contacts and blocked cooling
Ma'rib192 km north-west17,000dust on contacts and blocked cooling
Zinjibar222 km south-west20,000terminals loosening and parts running hot
Mukalla247 km east595,000terminals loosening and parts running hot
Dhamar261 km west160,000dust on contacts and blocked cooling
Yarim266 km west33,000dust on contacts and blocked cooling

In a smaller city like Ataq, local stock is often limited to common ratings. Keep spares of the parts that stop a system, and order the rest with a clear nameplate list.

The sun and the clock in Ataq

The clock in Ataq follows UTC+3 all year.

Ataq lies at 14.5° N, 46.8° E. Daylight lasts about 12 h 59 min at the June solstice and about 11 h 16 min in December, with a noon sun 81° and 52° high; the sun climbs almost to the zenith, so outdoor units on roofs and in open yards take the full load of its heat. Ataq has a hot and arid climate, which differs from the highland climate that describes Yemen overall; 20 other listed cities share it.

Typical uses of contactors in Ataq

In Ataq, these are the jobs that most often call for contactors:

  • Condenser fan switching
  • Heat pump defrost and reversing controls
  • Compressor control in split and packaged air conditioners

Klima contactors models

ModelPolesRated current (A)Coil voltage (V)
Klima 2-Pole Contactor 25 A, 24 V Coil22524 V AC
Klima 2-Pole Contactor 25 A, 230 V Coil225230 V AC
Klima 3-Pole Contactor 25 A, 24 V Coil32524 V AC
Klima 3-Pole Contactor 32 A, 24 V Coil33224 V AC

See the full Klima Contactors range for specifications, standards and a plain-language guide to choosing the right part.

Choosing contactors for Ataq

  • Size by motor current, not by horsepower alone. Use the compressor nameplate RLA and LRA, and choose a contactor with a rated operating current above them.
  • Ask for the datasheet and the documents your project needs; in Yemen that usually means YSMO (Yemen Standardization, Metrology and Quality Control Organization) requirements.

Care and maintenance in Ataq

  • Inspect contacts at each seasonal service; blackened, pitted or welded contacts mean replace, never file.

In the northern hemisphere the busiest cooling months fall from May to September; March or April is a sensible time to check contactors in Ataq. A failed electrical part in the peak weeks means a day without cooling, so replace weak ones early.

Faults to watch for

  • Burnt or welded contacts that keep the unit running when switched off

Supply and delivery to Ataq

To order contactors for Ataq, give a delivery address or a collection point in your enquiry, and mention whether road, sea or air delivery suits the job.

National rules, standards and voltage for Yemen are summarised on the country page.

Wholesalers and installers who buy regularly can ask about trade terms. See the distributors page.

Contactors in Ataq: common questions

Can I replace a contactor with a higher amp rating?

Yes. A higher rated current is safe and usually longer lasting, provided the coil voltage, pole count and physical size suit the installation.

What voltage should contactors be rated for in Ataq?

The mains supply in Yemen is 230 V, 50 Hz. Match contactors to that voltage class and confirm whether the equipment is single-phase or three-phase before you order.

How are contactors delivered to Ataq?

Shipments for Ataq normally clear customs at one of the main entry points of Yemen and finish the journey by road; send your delivery address with the enquiry.

Which parts of Ataq can I order for?

Enquiries are welcome from every part of Ataq. Send the delivery address with your enquiry.

Which cities near Ataq can the same order serve?

The listed cities closest to Ataq are Al Bayda (149 km south-west), Ma'rib (192 km north-west) and Zinjibar (222 km south-west). Combine them into one order and give each delivery address.

What local time and daylight should I plan for in Ataq?

Ataq keeps UTC+3 all year. At 14.5° N there are about 12 h 59 min of daylight in June and about 11 h 16 min in December.

More Klima products for Ataq

Contactors in cities near Ataq